Semantic search

Jump to navigation Jump to search
 Start dateReporting criterionTitleEvent descriptionSystemLER
ENS 402234 October 2003 07:00:0010 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluationDefects and Noncompliance ReportGE Nuclear Energy provided information concerning a reportable condition on the stability Option III Period Based Detection Algorithm (PBDA) for the Oscillation Power Range Monitor (OPRM) installed at the affected Licensee plants listed below. The basic component with the defect is specification of the allowable values for the adjustable period confirmation variables in the PBDA used in Stability Option III. The defect is that certain values of period tolerance and conditioning filter cutoff frequency within the previously specified acceptable range could produce sufficient successive confirmation count resets such that Safety Limit Minimum Critical Power Ratio (SLMCPR) protection might not be provided for all anticipated reactor instabilities. This condition does not produce a substantial safety hazard and there is no threat of fuel failure. However, because the condition could contribute to exceeding the SLMCPR, it is a reportable condition. List of Affected Plants: Clinton Brunswick 1 & 2 Nine Mile Point 2 Fermi 2 Columbia Dresden 2 & 3 LaSalle 1 & 2 Limerick 1 & 2 Peach Bottom 2 & 3 Quad Cities 1 & 2 Perry 1 Susquehanna 1 & 2 Hope Creek Hatch 1 & 2 Browns Ferry 2 & 3