ENS 519169 May 2016 05:00:00Agreement StateAgreement State Report - Fixed Nuclear Gauge Stuck Shutter

The following information was received via E-mail: On May 10, 2016, the Agency (Texas Depart of State Health Services) received notification from the licensee's radiation safety officer (RSO) that the shutter on a Thermo Fisher Scientific Model 5176-SN B2578 density gauge, containing a 500 millicurie cesium-137 source SN MA3200, was found open during inventory/operational checks. It appears the weld had failed on the gauge. Open is the normal operating position of the gauge shutter. The gauge does not create an exposure hazard to the licensee's employees or a member of the general public. The licensee has contacted the service company who will inspect the gauge. Additional information will be provided as it is received in accordance with SA-300. Texas Incident #: I-9399

  • * * RETRACTION FROM CHRIS MOORE TO RICHARD SMITH ON JUNE 10, 2016 AT 1541 EDT * * *

The following was received from the State of Texas via email: I-9399, EN51916 is retracted. The manufacturer inspected the gauge and shutter. All components were fully operational. The transmitter in the density detector failed, giving an erroneous reading on the meter. The licensee incorrectly assumed it was due to a broken shutter. Notified R4DO(Kramer) and NMSS Events Notification via email.

ENS 509586 April 2015 05:00:00Agreement StateAgreement State Report - Density Gauge Broken ShutterThe following information was received via E-mail: On April 6, 2015, the licensee radiation safety officer reported that a density measuring device, ThermoFisher Scientific model 5201, with Texas Nuclear Source Cesium-137, 100 millicuries, serial number GV-2806 had a broken shutter. The shutter block is disconnected from the arm. A ThermoFisher Scientific service technician has been contacted and scheduled to repair the gauge at the site. The shutter remains in the closed position until repairs are completed. There is no exposure hazard to any individual. Updates will be provided in accordance with SA300 guidelines. Texas Incident Number: I-9297
ENS 4197631 August 2005 05:00:00Agreement StateTexas Agreement State Report - Lost Nuclear Gauges