Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
ML16127A595 | 4 May 2016 | Rotork Controls Inc. Part 21 Notification Concerning V12 (Pt No. N69-921) and K5 (N69-838 & N69-926) Safety Related Micro Switches | Coatings |
ML15243A174 | 25 August 2015 | Part 21 Furmanite Nuclear Grade Leak Seal Material FSC-N-1B | |
ML13165A342 | 12 June 2013 | 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers | |
ML13094A177 | 18 March 2013 | Notice to the U.S. Nuclear Regulatory Commission of a Possible Deviation or Defect in Nuclear Qualified High Efficiency Particulate Air Filters Manufactured by Aaf | |
ML12219A305 | 3 August 2012 | Part 21 - Defective Valve Seal Cap | |
ML090761188 | 11 March 2009 | Part 21 Notification - Defective Hk and K-Line Circuit Breaker Tension Springs | |
ML081130777 | 15 April 2008 | 10CFR21 Reporting of Defects and Non-Compliance - Engine System, Inc. Report No. 10CFR21-0094, Rev. 0, Plunger and Barrel Assembly, Fuel Injection Pump Haynes P/N 9041367 | |
ML051160241 | 14 April 2005 | Thermo Electron Svioc, SV18C and SV28C Series Recorders | |
ML041450498 | 13 May 2004 | Abb, Inc. Report of Potential Defect Per 10CFR Part 21 Indicating Instantaneous Trip Unit on Type Co and COM Relays |