08/03/2012 Part 21 (PAR)
U.S. Nuclear Regulatory Commission Operations Center Event Report eaze I Event#
48157 Rep Org: FLOWSERVE Notification Date / Time: 08/03/2012 14:34 (EDT)
Supplier: FLOWSERVE Event Date / Time: 08/03/2012 (EDT)
Last Modification: 08/03/2012 Region:
1 Docket #:
City:
RALEIGH Agreement State:
Yes County:
License #:
State: NC NRC Notified by: ROBERT BARRY Notifications:
PAUL KROHN R1DO HQ Ops Officer: CHARLES TEAL MIKE ERNSTES R2DO Emergency Class: NON EMERGENCY MICHAEL KUNOWSKI R3DO 10 CFR Section:
PART 21 GROUP EMAIL 21.21 (d)(3)(i)
DEFECTS AND NONCOMPLIANCE PART 21 - DEFECTIVE VALVE SEAL CAP The following was provided via fax:
Background:
"On July 17, 2012, Duke Power - McGuire NPP notified Flowserve Corporation that they had attempted to install a Seal Cap supplied by Flowserve on a Kerotest 1-1500 Y-Type Globe Valve. They found that the Seal Cap could not be installed on the valve due to interference with the Valve Stem.
"Discussion:
"The Seal Cap is used to contain leakage past the Valve Diaphragm. The Seal Cap fits over the Valve Stem after Handle removal and is screwed onto the Yoke until it contacts the top of the Body. It is then seal welded to the Body to create a leak tight cap. At this point the Seal Cap is considered pressure retaining.
"Inspection of the Seal Cap revealed an inside flat bottom in lieu of the conical bottom shown on the drawing. The conical drill point allows clearance for the valve stem when the Seal Cap is installed on the valve. Review of a layout shows the Seal Cap with a Flat bottom cannot be completely installed whether the valve is open or closed.
"Conclusion:
"The Seal Cap with a flat bottom cannot be properly installed on the Kerotest Series R9900 size 1/2 to 2 Valves for which it was designed. The Valve Stem will prevent complete installation and the ability to seal weld the Seal Cap to the Body. The Seal Caps supplied would not be available at the Nuclear Power Plant site for an urgent repair if I ::q
08/03/2012 U.S. Nuclear Regulatory Commission Operations Center Event Report Pae 2 Part 21 (PAR)
Event#
48157 required. The following Nuclear Power Plant Utilities were provide these Seal Caps without the conical shaped area.
TVA - Purchase Order# 00020077-00050 and 00020077-00018 First Energy - Purchase Order# 45108999, and 45254808 Alabama Power - Purchase Order# QP040387, QP040872 and QP060575 Duke Power - Purchase Order # NM18494 001, NM25245, 00108212 and 00124677.
"Based on the above, the Nuclear Utilities need to be notified concerning this deviation so that an evaluation may be performed to determine if this constitutes a defect that could create a substantial safety hazard."
Aug, 3, 2012 2:34PM No. 0234 P. 2 US NRC August 3, 2012 Page 2 of 2 Conclusion The Seal Cap with a flat bottom cannot be properly installed on the Kerotest Series R9900 size 1/2 to 2 Valves for which it was designed. The Valve Stem will prevent complete installation and the ability to seal weld the Seal Cap to the Body. The Seal Caps supplied would not be available at the Nuclear Power Plant site for an urgent repair if required.
The following Nuclear Power Plant Utilities were provide these Seal Caps without the conical shaped area.
TVA - Purchase Order# 00020077-00050 and 00020077-00018 First Energy - Purchase Order# 45108999, and 45254808 Alabama Power - Purchase Order# QP040387, QP040872 and QP060575 Duke Power - Purchase Order # NM18494 001, NM25245, 00108212 and 00124677.
Based on the above, the Nuclear Utilities need to be notified concerning this deviation so that an evaluation may be performed to determine if this constitutes a defect that could create a substantial safety hazard.
Respectfully submitted, Robert D. Barry Manager, Quality Assurance Flowserve Corporation Flow Control Division 1900 S. Saunders St.
Raleigh, N.C. 27603
Aug, 3. 2012 2:34PM No, 0234 F. 2 US NRC August 3, 2012 Page 2 of 2 Conclusion The Seal Cap with a flat bottom cannot be properly installed on the Kerotest Series R9900 size 1/2 to 2 Valves for which it was designed. The Valve Stem will prevent complete installation and the ability to seal weld the Seal Cap to the Body. The Seal Caps supplied would not be available at the Nuclear Power Plant site for an urgent repair if required.
The following Nuclear Power Plant Utilities were provide these Seal Caps without the conical shaped area.
TVA - Purchase Order# 00020077-00050 and 00020077-00018 First Energy - Purchase Order# 45108999, and 45254808 Alabama Power - Purchase Order# QP040387, QP040872 and QP060575 Duke Power - Purchase Order # NM18494 001, NM25245, 00108212 and 00124677.
Based on the above, the Nuclear Utilities need to be notified concerning this deviation so that an evaluation may be performed to determine if this constitutes a defect that could create a substantial safety hazard.
Respectfully submitted, Robert D. Barry Manager, Quality Assurance Flowserve Corporation Flow Control Division 1900 S. Saunders St.
Raleigh, N.C. 27603