4300 Winfield Road Warrenville, IL 60555 Exelon Generation 630 657 2000 Office RS-20-031 April 30, 2020 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Dresden Nuclear Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-19 and DPR-25 NRC Docket Nos. 50-237 and 50-249 LaSalle County Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-11 and NPF-18 NRC Docket Nos. 50-373 and 50-374 Limerick Generating Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352 and 50-353 Nine Mile Point Nuclear Station, Unit 2 Renewed Facility Operating License No. NPF-69 NRC Docket No. 50-410 Peach Bottom Atomic Power Station, Units 2 and 3 10 CFR 50.90 Subsequent Renewed Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos. 50-277 and 50-278 Quad Cities Nuclear Power Station, Units 1 and 2 Renewed Facility Operating License Nos. DPR-29 and DPR-30 NRC Docket Nos. 50-254 and 50-265

SUBJECT:

License Amendment Request - Application to Adopt Technical Specification Task Force (TSTF) Traveler TSTF-568, Revision 2, "Revise Applicability of BWR/4 TS 3.6.2.5 and TS 3.6.3.2", Using the Consolidated Line Item Improvement Process Pursuant to 10 CFR 50.90, "Application for amendment of license, construction permit, or early site permit," Exelon Generation Company, LLC (EGC) is requesting approval for proposed changes to the Technical Specifications (TS), Appendix A of Renewed Facility Operating License (FOL) Nos. DPR-19 and DPR-25 for Dresden Nuclear Power Station (DNPS), Units 2 and 3; Renewed FOL Nos. NPF-11 and NPF-18 for LaSalle County Station (LSCS), Units 1 and 2; Renewed FOL Nos. NPF-39 and NPF-85 for Limerick Generating Station (LGS), Units 1 and 2; Renewed FOL No. NPF-69 for Nine Mile Point (NMP), Unit 2; Subsequent Renewed FOL

April 30, 2020 U.S. Nuclear Regulatory Commission Page 2 Nos. DPR-44 and DPR-56 for Peach Bottom Atomic Power Station (PBAPS), Units 2 and 3; and Renewed FOL Nos. DPR-29 and DPR-30 for Quad Cities Nuclear Power Station (QCNPS),

Units 1 and 2.

EGC requests adoption of TSTF-568, "Revise Applicability of BWR/4 TS 3.6.2.5 and TS 3.6.3.2." TSTF-568 revises the Applicability and Actions of Technical Specification (TS) 3.6.2.5, "Drywell-to-Suppression Chamber Differential Pressure," and TS 3.6.3.2, "Primary Containment Oxygen Concentration," and presents the requirements in a manner more consistent with the Standard Technical Specifications (STS) format and content. provides a description and assessment of the proposed change.

Attachments 2a through 2f provide the existing TS pages marked to show the proposed change. Attachments 3a through 3f provide the existing TS Bases pages marked to show revised text associated with the proposed TS changes and are provided for information only. Attachments 4a through 4f provide revised (i.e., clean) TS pages for the affected stations.

EGC requests review of this amendment request under the Consolidated Line Item Improvement Process (CLllP). Approval of the proposed amendments is requested by April 30, 2021. Once approved, the amendments shall be implemented within 90 days.

EGC has concluded that the proposed changes present no significant hazards consideration under the standards set forth in 10 CFR 50.92, "Issuance of amendments."

The proposed changes have been reviewed by the Plant Operations Review Committees for the affected units in accordance with the requirements of the Exelon Quality Assurance Program.

In accordance with 10 CFR 50.91, "Notice for public comment; State consultation," paragraph (b), Exelon is notifying the States of Illinois, Pennsylvania, and New York of this application for license amendments by transmitting a copy of this letter and its attachments to the designated State Officials.

There are no regulatory commitments contained in this letter. If you have any questions or require additional information, please contact Phillip Henderson at (630) 657-4727.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 301h day of April 2020.

Respectfully, P~R~---~

Patrick R. Simpson Sr. Manager - Licensing Exelon Generation Company, LLC

April 30, 2020 U.S. Nuclear Regulatory Commission Page 3 Attachments:

1. Evaluation of Proposed Changes cc:

2a. Markup of Proposed Technical Specifications Pages - Dresden Nuclear Power Station, Units 2 and 3 2b. Markup of Proposed Technical Specifications Pages - LaSalle County Station, Units 1 and 2 2c. Markup of Proposed Technical Specifications Pages - Limerick Generating Station, Units 1 and 2 2d. Markup of Proposed Technical Specifications Pages - Nine Mile Point, Unit 2 2e. Markup of Proposed Technical Specifications Pages - Peach Bottom Atomic Power Station, Units 2 and 3 2f. Markup of Proposed Technical Specifications Pages - Quad Cities Nuclear Power Station, Units 1 and 2 3a. Markup of Proposed Technical Specifications Bases Pages and Inserts -

Dresden Nuclear Power Station, Units 2 and 3 (For Information Only) 3a.

3b. Markup of Proposed Technical Specifications Bases Pages and Inserts -

LaSalle County Station, Units 1 and 2 (For Information Only) 3c. Markup of Proposed Technical Specifications Bases Pages and Inserts -

Limerick Generating Station, Units 1 and 2 (For Information Only) 3d. Markup of Proposed Technical Specifications Bases Pages and Inserts -

Nine Mile Point, Unit 2 (For Information Only) 3e. Markup of Proposed Technical Specifications Bases Pages and Inserts -

Peach Bottom Atomic Power Station, Units 2 and 3 (For Information Only) 3f. Markup of Proposed Technical Specifications Bases Pages and Inserts -

Quad Cities Nuclear Power Station, Units 1 and 2 (For Information Only) 4a. Revised (Clean) Technical Specifications Pages - Dresden Nuclear Power Station, Units 2 and 3 4b. Revised (Clean) Technical Specifications Pages - LaSalle County Station, Units 1 and 2 4c. Revised (Clean) Technical Specifications Pages - Limerick Generating Station, Units 1 and 2 4d. Revised (Clean) Technical Specifications Pages - Nine Mile Point, Unit 2 4e. Revised (Clean) Technical Specifications Pages - Peach Bottom Atomic Power Station, Units 2 and 3 4f. Revised (Clean) Technical Specifications Pages - Quad Cities Nuclear Power Station, Units 1 and 2 Regional Administrators - NRC Regions I and Ill w/ attachments NRC Senior Resident Inspectors - DNPS, LSCS, LGS, NMP2, PBAPS, QCNPS NRC Project Manager, NRR - DNPS, LSCS, LGS, NMP2, PBAPS, QCNPS Illinois Emergency Management Agency - Division of Nuclear Safety A. L. Peterson - NYSERDA Director, Bureau of Radiation Protection - Pennsylvania Department of Environmental Protection II II II II II

ATTACHMENT 1 Exelon Generation Company, LLC Request to Adopt Technical Specifications Task Force (TSTF) Traveler TSTF-568, "Revise Applicability of BWR/4 TS 3.6.2.5 and TS 3.6.3.2" Evaluation of Proposed Changes Evaluation of Proposed Changes Page 1of6

Subject:

License Amendment Request - to Adopt TSTF-568, Rev 2

1.0 DESCRIPTION

2.0 ASSESSMENT

2.1 Applicability of Safety Evaluation 2.2 Optional Changes and Variations

3.0 REGULATORY ANALYSIS

3.1 No Significant Hazards Consideration Analysis 3.2 Conclusion

4.0 ENVIRONMENTAL CONSIDERATION

1.0 DESCRIPTION

Evaluation of Proposed Changes Page 2 of 6 Exelon Generation Company, LLC (EGC) requests to adopt Technical Specification Task Force (TSTF) Traveler TSTF-568, "Revise the Applicability of BWR TS 3.6.2.5 and TS 3.6.3.2," in the Technical Specifications (TS) for Dresden Nuclear Power Station (DNPS), Units 2 and 3; LaSalle County Station (LSCS), Units 1 and 2; Limerick Generating Station (LGS), Units 1 and 2; Nine Mile Point (NMP), Unit 2; Peach Bottom Atomic Power Station (PBAPS), Units 2 and 3; and Quad Cities Nuclear Power Station (QCNPS), Units 1 and 2. TSTF-568 revises the Applicability and Actions of TS 3.6.2.5, "Drywell-to-Suppression Chamber Differential Pressure," and 3.6.3.1, "Primary Containment Oxygen Concentration," for DNPS, Units 2 and 3 and QCNPS, Units 1 and

2. The remaining units that are included in this request do not have a Technical Specification for Drywell-to-Suppression Chamber Differential Pressure; therefore, the requested changes for these units is limited to Technical Specification 3.6.3.2, "Primary Containment Oxygen Concentration," for LSCS, Units 1 and 2, NMP, Unit 2, and PBAPS, Units 2 and 3, and Technical Specification 3.6.6.3, "Drywell and Suppression Chamber Oxygen Concentration," for LGS, Units 1 and 2. The proposed changes present the associated requirements in a manner that is more consistent with the Standard Technical Specifications (STS) format and content.

2.0 ASSESSMENT

2.1 Applicability of Safety Evaluation EGC has reviewed the Safety Evaluation for TSTF-568 provided to the TSTF in a letter dated December 17, 2019. This review also included a review of the NRC's evaluation, as well as the information provided in TSTF-568. EGC has concluded that the justifications presented in TSTF-568 and the safety evaluation prepared by the NRC are applicable to the stations listed in Section 1.0 above and justify the requested amendments for the incorporation of the changes to the DNPS, Units 2 and 3; LSCS, Units 1 and 2; LGS, Units 1 and 2; NMP, Unit 2; PBAPS, Units 2 and 3; and QCNPS, Units 1 and 2 TS.

2.2 Optional Changes and Variations In some instances, EGC operating units have different TS numbering or titles than the Standard Technical Specifications on which TSTF-568 was based. Specifically, the numbering and title differences are as follows:

1. The DNPS, Units 2 and 3 and QCNPS, Units 1 and 2 TS utilize different numbering than the Standard Technical Specifications on which TSTF-568 was based.

Specifically, Technical Specification 3.6.3.2, "Primary Containment Oxygen Concentration," corresponds to Technical Specification 3.6.3.1 for DNPS, Units 2 and 3 and QCNPS, Units 1 and 2. Additionally, TSTF-568, Technical Specification 3.6.3.2, corresponds to Technical Specification 3.6.6.3, "Drywell and Suppression Chamber Oxygen Concentration," for LGS, Units 1 and 2. These Evaluation of Proposed Changes Page 3 of 6 differences are administrative in nature and do not affect the applicability of TSTF-568 to the DNPS, LGS and QCNPS TS.

2. The proposed change to TS 3.6.2.5, "Drywell-to-Suppression Chamber Differential Pressure," in TSTF-568 is not applicable to LSCS, Units 1 and 2; LGS, Units 1 and 2; NMP, Unit 2; and PBAPS, Units 2 and 3, since these units do not have such a Technical Specification.
3. The LGS, Units 1 and 2 TS are based on the previous version of the NRC's STS (i.e., NUREG-0123, "Standard Technical Specifications for General Electric Boiling Water Reactors (BWR/5)", Revision 2); therefore, the wording and format varies slightly from the NRC Improved STS (i.e., NUREG-1433, "Standard Technical Specifications for General Electric Boiling Water Reactors (BWR/4 )") shown in TSTF-568, and the applicable parts of the NRC's safety evaluation. This minor variation is administrative in nature and does not affect the applicability of TSTF-568 to the LGS TS.

The DNPS, Units 2 and 3 and QCNPS, Units 1 and 2 TS 3.6.2.5 "Drywell-to-Suppression Chamber Differential Pressure," include a note that allows for the TS to not be met for up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during the performance of required surveillances. This note is being removed to be consistent with the revised applicability. This difference does not affect the applicability of the proposed change and is consistent with the STS in format and content.

3.0 REGULATORY ANALYSIS

3.1 No Significant Hazards Consideration Analysis Exelon Generation Company, LLC (EGC) requests to adopt Technical Specifications Task Force (TSTF) traveler TSTF-568, "Revise Applicability of BWR/4 Technical Specifications (TS) 3.6.2.5 and TS 3.6.3.2, "in the TS for Dresden Nuclear Power Station (DNPS), Units 2 and 3, LaSalle County Station (LSCS), Units 1 and 2, Limerick Generating Station (LGS), Units 1 and 2, Nine Mile Point (NMP), Unit 2, Peach Bottom Atomic Power Station (PBAPS), Units 2 and 3, and Quad Cities Nuclear Power Station (QCNPS), Units 1 and 2. TSTF-568 revises the Applicability and Actions of TS 3.6.2.5, "Drywell-to-Suppression Chamber Differential Pressure," and 3.6.3.1, "Primary Containment Oxygen Concentration," for DNPS, Units 2 and 3 and QCNPS, Units 1 and 2. The remaining units that are included in this request do not have a Technical Specification for Drywell-to-Suppression Chamber Differential Pressure; therefore the requested changes for these units is limited to Technical Specification 3.6.3.2, "Primary Containment Oxygen Concentration," for LSCS, Units 1 and 2; NMP, Unit 2; and PBAPS, Units 2 and 3, and Technical Specification 3.6.6.3, "Drywell and Suppression Chamber Oxygen Concentration," for LGS, Units 1 and 2. The adoption of TSTF-568 as proposed would result in the presentation of the associated requirements in a manner that is more consistent with the Standard Technical Specifications (STS) in format and content.

Evaluation of Proposed Changes Page 4 of 6 EGC has evaluated if a significant hazards consideration is involved with the proposed amendments by focusing on the three standards set forth in 10 CFR 50.92, "Issuance of amendment," as discussed below:

1. Does the proposed amendment involve a significant increase in the probability or consequences of an accident previously evaluated?

Response: No.

The proposed change revises the Applicability and Actions of the TS for drywell-to-suppression chamber differential pressure, and Primary Containment oxygen concentration, and presents the requirements in a manner more consistent with the STS in format and content. Drywell-to-suppression chamber differential pressure and primary containment oxygen concentration (i.e., Drywell and Suppression Chamber Oxygen Concentration for LGS, Units 1 and 2) are not initiators to any accident previously evaluated. As a result, the probability of any accident previously evaluated is not affected by the proposed change.

Drywell-to-Suppression Chamber Differential Pressure and Primary Containment Oxygen Concentration are assumptions in the mitigation of some accidents previously evaluated. The Applicability of the TS related to oxygen concentration is changed from Mode 1 (i.e., Operational Condition 1 for LGS, Units 1 and 2) when thermal power is greater than 15% to Modes 1 and 2. This expands the Applicability of the TS and will not have an effect on the consequences of an accident. The existing Applicability exceptions are removed and replaced with a longer Completion Time of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. The consequences of an event that could affect the drywell-to-suppression chamber differential pressure and Primary Containment (i.e., Drywell and Suppression Chamber Oxygen Concentration for LGS, Units 1 and 2) oxygen concentration are no different during the proposed Completion Time than the consequences of the same event during the existing Completion Times. A note referencing Limiting Condition for Operation (LCO) 3.0.4.c is added to the Actions to permit entering the Applicability with the LCO not met. The note replaces the existing Applicability exceptions. This change is administrative and has no effect on the consequences of an accident.

Therefore, the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.

2. Does the proposed amendment create the possibility of a new or different kind of accident from any accident previously evaluated?

Response: No.

The proposed change revises the Applicability and Actions of the TS for Drywell-to-Suppression Chamber Differential Pressure, and Primary Containment Oxygen Concentration (i.e., Drywell and Suppression Chamber Oxygen Concentration for LGS, Units 1 and 2) and presents the requirements in a manner that is more Evaluation of Proposed Changes Page 5 of 6 consistent with the STS in format and content. The proposed change does not involve a physical alteration of the plant (i.e., no new or different type of equipment will be installed). No credible new failure mechanisms, malfunctions, or accident initiators that would have been considered a design basis accident in the Updated Final Safety Analysis Report (UFSAR) are created because the NRC has determined that hydrogen generation is not risk significant for design basis accidents.

Therefore, the proposed change does not create the possibility of a new or different kind of accident from any accident previously evaluated.

3. Does the proposed amendment involve a significant reduction in a margin of safety?

Response: No.

The proposed change revises the Applicability and Actions of the TS for Drywell-to-Suppression Chamber Differential Pressure, and Primary Containment Oxygen Concentration (i.e., Drywell and Suppression Chamber Oxygen Concentration for LGS, Units 1 and 2) and presents the requirements in a manner that is more consistent with the STS in format and content. No safety limits are affected. No LCOs or Surveillance limits are affected. The Drywell-to-Suppression Chamber Differential Pressure and Primary Containment Oxygen Concentration (i.e., Drywell and Suppression Chamber Oxygen Concentration for LGS, Units 1 and 2) TS requirements assure sufficient safety margins are maintained, and that the design, operation, surveillance methods, and acceptance criteria specified in applicable codes and standards (or alternatives approved for use by the NRC) will continue to be met as described in the plants' licensing basis. The proposed change does not adversely affect existing plant safety margins or the reliability of the equipment assumed to operate in the safety analysis. As such, there are no changes being made to safety analysis assumptions, safety limits, or limiting safety system settings that would adversely affect plant safety.

Therefore, the proposed change does not involve a significant reduction in a margin of safety.

Based upon the above, EGC concludes that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of "no significant hazards consideration" is justified.

3.2 Conclusion In conclusion, based on the considerations discussed above, (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.

Evaluation of Proposed Changes Page 6 of 6

4.0 ENVIRONMENTAL CONSIDERATION

The proposed change does not change a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or do not change an inspection or surveillance requirement. The proposed change does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluents that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure. Accordingly, the proposed change meets the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9).

Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed change.

ATTACHMENT 2a DRESDEN NUCLEAR POWER STATION, UNITS 2 AND 3 DOCKET NOS. 50-237 AND 50-249 RENEWED FACILITY OPERATING LICENSE NOS. DPR-19 AND DPR-25 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Dresden Proposed Technical Specifications Changes MARKED-UP TS PAGES 3.6.2.5-1 3.6.3.1-1

Drywell-to-Suppression Chamber Differential Pressure 3.6.2.5 3.6 CONTAINMENT SYSTEMS 3.6.2.5 Drywell-to-Suppression Chamber Differential Pressure LCO 3.6.2.5 The drywell pressure shall be maintained~ 1.0 psid above the pressure of the suppression chamber.

~et required to be met for up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during performance of required Surveillances.

APPLICABILITY:

MODE 1 with THERMAL POWER> 15% RTP. during the time period:

a.

F"rom 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after rnERMi\\L P0 1... 1ER is ) 15?& RTP foll 0 1.Ji ng startup, to

b.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to reducing THERM/\\L POWER to c 15% RTP prior to the next scheduled reactor shutdown.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

Drywel 1-to-suppressi on A.1


NOTE--------

chamber differential LCD 3.0.4.c is pressure not within applicable limit.

Restore differential 72-24 hours pressure to within limit.

B.

Required Action and 8.1 Reduce THERMAL POWER 12.g hours associated Completion to ~ 15% RTP.

Time not met.

Dresden 2 and 3 3.6.2.5-1 Amendment No. 185/180

Primary Containment Oxygen Concentration 3.6.3.1 3.6 CONTAINMENT SYSTEMS 3.6.3.1 Primary Containment Oxygen Concentration LCO 3.6.3.1 APPLICABILITY:

ACTIONS The primary containment oxygen concentration shall be

< 4.0 volume percent.

MODES 1 and 2. during the time period:

a.

From 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after THERMAL POWER is> 15% RTP following startup, to

b.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to reducing THERMAL POWER to c 15% RTP prior to the next scheduled reactor shutdo 1.m.

CONDITION REQUIRED ACTION COMPLETION TIME A.

Primary containment A.1


NOTE--------

oxygen concentration LCO 3.0.4.c is not within limit.

applicable Restore oxygen concentration to within limit.

B.

Required Action and B.1 Be in MODE 3Reduce associated Completion TM ERM!', L P0 1t.1ER to Time not met.

.:::; 15?& RTP.

SURVEILLANCE REQUIREMENTS SURVEILLANCE SR 3.6.3.1.1 Verify primary containment oxygen concentration is within limits.

72-24 hours 12S hours FREQUENCY In accordance with the Survei 11 ance Frequency Control Program Dresden 2 and 3 3.6.3.1-1 Amendment No. 237/230

ATTACHMENT 2b LASALLE COUNTY STATION, UNITS 1AND2 DOCKET NOS. 50-373 AND 50-374 RENEWED FACILITY OPERATING LICENSE NOS. NPF-11 AND NPF-18 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 LaSalle Proposed Technical Specifications Changes MARKED-UP TS PAGES 3.6.3.2-1

Primary Containment Oxygen Concentration 3.6.3.2 3.6 CONTAINMENT SYSTEMS 3.6.3.2 Primary Containment Oxygen Concentration LCO 3.6.3.2 APPLICABILITY:

ACTIONS The primary containment oxygen concentration shall be

< 4.0 volume percent.

MODES 1 and 2. during the time period:

a.

From 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after THERMAL POWER is> 15% RTP following startup, to

b.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to reducing THERMAL POWER to < 15% RTP prior to the next scheduled reactor shutdo 1.m.

CONDITION REQUIRED ACTION COMPLETION TIME A.

Primary containment A.1


NOTE--------

oxygen concentration LCO 3.0.4.c is not within limit.

applicable Restore oxygen concentration to within limit.

B.

Required Action and B.l Be in MODE 3Reduce associated Completion TM ERM!', L P0 11.'E R to Time not met.

< l 5?b RTP.

SURVEILLANCE REQUIREMENTS SURVEILLANCE SR 3.6.3.2.1 Verify primary containment oxygen concentration is within limits.

72-24 hours 12g. hours FREQUENCY In accordance with the Survei 11 ance Frequency Control Program LaSalle 1 and 2 3.6.3.2-1 Amendment No. 200/187

ATTACHMENT 2c LIMERICK GENERATING STATION, UNITS 1AND2 DOCKET NOS. 50-352 AND 50-353 RENEWED FACILITY OPERATING LICENSE NOS. NPF-39 AND NPF-85 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Limerick Proposed Technical Specifications Changes MARKED-UP TS PAGES 3/4 6-59 (Unit 1) 3/4 6-59 (Unit 2)

CONTAINMENT SYSTEMS DRYWELL AND SUPPRESSION CHAMBER OXYGEN CONCENTRATION LIMITING CONDITION FOR OPERATION 3.6.6.3 The drywell and suppression chamber atmosphere oxygen concentration shall be less than 4% by volume.

APPLICABILITY:

OPERATIONAL CONDITIONS 1* and 2., during the time period:

a.

Within 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s** after THERMAL POWER is greater than 15% of RATED THERMAL POWER, following startup, to

b.

Within 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s** prior to reducing THERMAL POWER to less than 15% of RATED THERMAL POWER, preliminary to a scheduled reactor shutdown.

ACTION:

With the drywell and/or suppression chamber oxygen concentration exceeding the limit, restore the oxygen concentration to within the limit within --72 hours or be in at least STARTUP HOT SHUTDOWN within the next &-12 hours. The provision of Specification 3.0.4.c is applicable.

SURVEILLANCE REQUIREMENTS 4.6.6.3 The drywell and suppression chamber oxygen concentration shall be verified to be within the limit 11ithin 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after THERMAL POWER is greater than 15% of RATED THERMAL POWER and in accordance with the Surveillance Frequency Control Program thereafter.

  • See Special Test Exception 3.10.5.
    • Specification 3.6.1.8 is applicable during this 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period.

LIMERICK - UNIT 1 3/4 6-59 Amendment No. -+/-.ge

CONTAINMENT SYSTEMS DRYWELL AND SUPPRESSION CHAMBER OXYGEN CONCENTRATION LIMITING CONDITION FOR OPERATION 3.6.6.3 The drywell and suppression chamber atmosphere oxygen concentration shall be less than 4% by volume.

APPLICABILITY:

OPERATIONAL CONDITIONS l* and 2., during the time period:

a.

Within 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s** after THERMAL POWER is greater than 15% of RATED THERMAL POWER, following startup, to

b.

Within 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s** prior to reducing THERMAL POWER to less than 15% of RATED THERMAL POWER, preliminary to a scheduled reactor shutdo\\1n.

ACTION:

With the drywell and/or suppression chamber oxygen concentration exceeding the limit, restore the oxygen concentration to within the limit within -72 hours or be in at least STARTUP HOT SHUTDOWN within the next.g.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. The provision of Specification 3.0.4.c is applicable.

SURVEILLANCE REQUIREMENTS 4.6.6.3 The drywell and suppression chamber oxygen concentration shall be verified to be within the limit within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after THERMAL POWER is greater than 15% of RATED THERMAL POWER and in accordance with the Surveillance Frequency Control Program thereafter.

  • See Special Test Exception 3.10.5.
    • Specification 3.6.1.8 is applicable during this 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period.

LIMERICK - UNIT 2 3/4 6-59 Amendment No. -+/-4+

ATTACHMENT 2d NINE MILE POINT, UNIT2 DOCKET NO. 50-410 RENEWED FACILITY OPERATING LICENSE NO. NPF-69 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Nine Mile Point Proposed Technical Specifications Changes MARKED-UP TS PAGES 3.6.3.2-1

Primary Containment Oxygen Concentration 3.6.3.2 3.6 CONTAINMENT SYSTEMS 3.6.3.2 Primary Containment Oxygen Concentration LCO 3.6.3.2 The primary containment oxygen concentration shall be

< 4.0 volume percent.

APPLICABILITY:

MODES 1 and 2. 1 during the time period:

a.

From 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after THERMAL POVVER is > 15% RTP following startup, to

b.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to reducing THERMAL POWER to < 15% RTP prior to the next scheduled reactor shutdown.

ACTIONS CONDITION REQUIRED ACTION A.

Primary containment A.1


N 0 TE------------

oxygen concentration LCO 3.0.4.c is not within limit.

applicable Restore oxygen concentration to within limit.

B.

Required Action and B.1 Be in MODE 3. Reduce associated Completion THERMAL POVVER to Time not met.

< 15% RTP.

SURVEILLANCE REQUIREMENTS SURVEILLANCE SR 3.6.3.2.1 NMP2 Verify primary containment oxygen concentration is within limits.

3.6.3.2-1 COMPLETION TIME 7224 hours0.0836 days <br />2.007 hours <br />0.0119 weeks <br />0.00275 months <br /> 12f> hours FREQUENCY In accordance with the Surveillance Frequency Control Program Amendment 91, 152

ATTACHMENT 2e PEACH BOTTOM ATOMIC POWER STATION, UNITS 2 AND 3 DOCKET NOS. 50-277 AND 50-278 SUBSEQUENT RENEWED FACILITY OPERATING LICENSE NOS. DPR-44 AND DPR-56 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Peach Bottom Proposed Technical Specifications Changes MARKED-UP TS PAGES X.Y-Z

Pr imary Conta i nment Oxygen Concentrat i on 3.6.3.2 3.6 CONTAI NM ENT SYSTEMS 3.6.3.2 Pr i mary Containment Oxygen Concentration LCO 3.6.3.2 The pr imary con t ai nment oxygen concentrat i on shall be

< 4.0 volume percent.

APPLI CAB ILITY:

MO DES 1 and 2.during the time period:

a.

From 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after THERMAL POWER is> 15% RTP following startup, to

b.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to reducing THERMAL POWER to < 15% RTP prior to a reactor shutdown.

ACTI ONS COND ITIO N REQUI RED ACTI ON COM PLETION TI ME A.

Pr imary conta i nment A. 1


NOTE---------

oxygen concentrat i on LCO 3.0.4.c is not wi t hi n l imi t.

applicable.

Restore oxygen 7224 hours0.0836 days <br />2.007 hours <br />0.0119 weeks <br />0.00275 months <br /> concentrat i on to with in limit.

B.

Requ i red Act i on and B. 1 Be in MODE 3. Reduce assoc i ated Completi on THERMAL POWER to Time not met.

.::; l 5?b RTP.

SURV EILLANC E REQUI REMENTS SR 3.6.3.2. 1 PBA PS UN IT 2 SURV EILLANC E Ver ify pr i mary conta i nment oxygen concentrat i on i s wi t hi n l imi ts.

3.6-33 lzg hours FREQUE NCY In accordance wi t h t he Surve i llance Frequency Control Program.

Amendmen t No. f..g

Pr imary Conta i nment Oxygen Concentrat i on 3.6.3.2 3.6 CONTAI NM ENT SYSTEMS 3.6.3.2 Pr i mary Containment Oxygen Concentration LCO 3.6.3.2 The pr imary con t ai nment oxygen concentrat i on shall be

< 4.0 volume percent.

APPLI CAB ILITY:

MO DES 1 and 2.during the time period:

a.

From 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after THERMAL POWER is> 15% RTP following startup, to

b.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to reducing THERMAL POWER to < 15% RTP prior to a reactor shutdown.

ACTI ONS COND ITIO N REQUI RED ACTI ON COM PLETION TI ME A.

Pr imary conta i nment A. 1


NOTE---------

oxygen concentrat i on LCO 3.0.4.c is not wi t hi n l imi t.

applicable.

Restore oxygen 7224 hours0.0836 days <br />2.007 hours <br />0.0119 weeks <br />0.00275 months <br /> concentrat i on to with in limit.

B.

Requ i red Act i on and B. 1 Be in MODE 3. Reduce assoc i ated Completi on THERMAL POWER to Time not met.

.::; l 5?b RTP.

SURV EILLANC E REQUI REMENTS SR 3.6.3.2. 1 PBA PS UN IT 3 SURV EILLANC E Ver ify pr i mary conta i nment oxygen concentrat i on i s wi t hi n l imi ts.

3.6-33 lzg hours FREQUE NCY In accordance wi t h t he Surve i llance Frequency Control Program.

Amendmen t No. &+/--

ATTACHMENT 2f QUAD CITIES NUCLEAR STATION, UNITS 1AND2 DOCKET NOS. 50-254 AND 50-265 RENEWED FACILITY OPERATING LICENSE NOS. DPR-29 AND DPR-30 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Quad Cities Proposed Technical Specifications Changes MARKED-UP TS PAGES 3.6.2.5-1 3.6.3.1-1

Drywell -t o-Suppress i on Chamber Differenti al Pressure

3. 6. 2. 5
3. 6 CONTAI NM ENT SYSTE MS
3. 6. 2. 5 Drywell -t o-Suppress i on Chamber Di fferen ti al Pressure LCO
3. 6. 2. 5 The drywe ll pressure sha ll be ma i n t a i ned~ 1.0 ps i d above t he pressure of t he suppress i on chamber.

~ot required to be met for up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during performance of required Surveillances.

APPLI CAB ILITY:

MO DE 1 with THERMAL POWER> 15% RTP.during the time period:

a.

F"rom 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after rnERMi\\L PQl;,'ER is > 15?b RTP foll 0 1.Ji ng startup, to

b.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to reducing THERM/\\L POWER to < 15% RTP prior to the next scheduled reactor shutdown.

ACTI ONS CON DITION REQUIRED ACTI ON COM PLETION TI ME A.

Drywe l 1-t o-suppress i on A.1


NOTE--------

chamber di fferen ti al LCD 3.0.4.c is pressure no t withi n applicable li mit.

Res t ore di ff erent ial 72-24 hours pressure t o withi n l imit.

B.

Requ i red Acti on and 8.1 Reduce THERMA L POW ER 12.g. hours assoc i at ed Comp l et i on t o :::; 15% RTP.

Ti me no t met.

Quad Citi es 1 and 2 3.6.2.5 -1 Amendmen t No. 199/195

Pr imary Con t ai nmen t Oxygen Concen t ra ti on 3.6.3.1 3.6 CONTAI NM ENT SYSTE MS 3.6.3.1 Pr imary Con t ai nmen t Oxygen Concentra ti on LCO 3.6.3.1 The pr imary con t ai nmen t oxygen concen t rat i on shall be

< 4.0 vo l ume percent.

APP LI CAB ILITY:

MOD ES 1 and 2. during the time period:

a.

F"rorn 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after Tl=IE"RMAL POWE"R is > 15?b RTP foll o*,.*i ng startup, to

b.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to reducing Tl=IE"RMAL POWE"R to < 15% RTP pr i or to the next sch e du l e d reactor shut do '>m

  • ACTI ONS COND IT ION REQUIR ED ACTI ON A.

Pr imary con t ai nment A.1


NOTE--------

oxygen concentration LCO 3.0.4.c is no t wit hi n li mi t.

applicable Restore oxygen concen t rat i on t o wit hi n li mit.

B.

Requ i red Act i on and B. 1 Be in MODE 3Reduce associated Comp l eti on Tl=I t RM/l, L PQI:,' t R to Time not met.

< l 5?b RTP.

SURV EILLANC E REQUI REMENTS SURV EILLANC E SR 3.6.3. 1.1 Ver i fy pr imary con t ai nmen t oxygen concen t rat i on i s wi t hi n li mi ts.

COM PLETION TI ME 72-2-4 hours 12g. hours FREQU ENCY In accordance wi th t he Surve i 11 ance Frequency Cont rol Program Quad Citi es 1 and 2 3.6.3. 1-1 Amendmen t No. 248/243

ATTACHMENT 3a DRESDEN NUCLEAR POWER STATION, UNITS 2 AND 3 DOCKET NOS. 50-237 AND 50-249 RENEWED FACILITY OPERATING LICENSE NOS. DPR-19 AND DPR-25 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Dresden Proposed Technical Specifications Bases Changes (for information only)

MARKED-UP TS BASES PAGES B 3.6.2.5-2 B 3.6.2.5-3 B 3.6.3.1-2 B 3.6.3.1-3

BASES LCO (continued)

APPLICABILITY ACTIONS Dresden 2 and 3 Drywell-to-Suppression Chamber Differential Pressure B 3.6.2.5 drywell-to-suppression chamber differential pressure of

< 1.0 psid corresponds to a downcomer water leg of

> 1.68 ft.

Failure to maintain the required differential pressure could result in excessive forces on the suppression chamber due to higher water clearing loads from downcomer vents and higher pressure buildup in the drywell.

A Note is provided to allow for periods of up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 1o1hen the LCO is not required to be met during the performance of required Surveillances that reduce the differential pressure.

The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> time is acceptable since the probability of a DBA LOCA occurring during this time is

+B-w.-

Drywell-to-suppression chamber differential pressure must be controlled when the primary containment is inert.

The primary containment must be inert in MODE 1 with THERMAL POWER > 15% RTP, since this is the condition with the highest probability for an event that could produce hydrogen.

It is also the condition 11ith the highest probability of an event that could impose large loads on the primary containment.

Inerting primary containment is an operational problem because it prevents primary containment access without an appropriate breathing apparatus.

Therefore, the primary containment is inerted as late as possible in the unit startup and is de inerted as soon as possible in the unit shutdo 1.m.

As long as reactor po 1o1er is < 15?& RTP, the probability of an event that generates hydrogen or excessive loads on primary containment occurring 1o1ithin the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> following a startup or within the last 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to a shutdo 1.m is l 0 1.1 enough that these 11 1t.1indows, 1' with the primary containment not inerted, are also justified.

The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> time period is a reasonable amount of time to allow plant personnel to perform inerting or de inerting.

If drywell-to-suppression chamber differential pressure is not within the limit, the conditions assumed in the safety analyses are not met and the differential pressure must be restored to within the limit within 72-&4 hours.

The 72-&4 hour Completion Time provides sufficient time to restore (continued)

B 3.6.2.5-2 Revision w

BASES ACTIONS SURVEILLANCE REQUIREMENTS REFERENCES Dresden 2 and 3 Drywell-to-Suppression Chamber Differential Pressure B 3.6.2.5 A......l (continued) differential pressure to 1.Jithin limit and takes into account the low probability of an event that would create excessive suppression chamber loads occurring during this time period.

A Note permits the use of the prov1s1ons of LCO 3.0.4.c.

This allowance permits entry into the applicable MODE(S) while relying on the ACTIONS.

This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus.

Therefore, the primary containment is inerted as late as possible in the plant startup, after entering Mode 1 with THERMAL POWER> 15% RTP, and de-inerted as soon as possible in the plant shutdown.

It is acceptable to intentionally enter Required Action A.1 prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

If the differential pressure cannot be restored to within limits within the associated Completion Time, the plant must be placed in a MODE in which the LCO does not apply.

This is done by reducing power to~ 15% RTP within 12S hours.

The 12S hour Completion Time is reasonable, based on operating experience, to reduce reactor power from full power conditions in an orderly manner and without challenging plant systems.

SR 3.6.2.5.1 The drywell-to-suppression chamber differential pressure is regularly monitored to ensure that the required limits are satisfied.

The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.

None.

B 3.6.2.5-3 Revision 9-

BASES APPLICABLE SAFETY ANALYSES (continued)

LCO APPLICABILITY ACTIONS Dresden 2 and 3 Primary Containment Oxygen Concentration B 3.6.3.1 combustible gas mixtures in the primary containment.

Oxygen, which is subsequently generated by radiolytic decomposition of water, will not result in the primary containment becoming de-inerted within the first 30 days following an accident.

Primary containment oxygen concentration satisfies 10 CFR 50.36(c)(2)(ii).

The primary containment oxygen concentration is maintained

< 4.0 v/o to ensure that an event that produces any amount of hydrogen and oxygen does not result in a combustible mixture inside primary containment.

The primary containment oxygen concentration must be within the specified limit when primary containment is inerted, except as allo 1.Jed by the relaxations during startup and shutdown addressed below.

The primary containment must be inert in MODES 1 and 2, since this is the condition with the highest probability of an event that could produce hydrogen and oxygen.

Inerting the primary containment is an operational problem because it prevents containment access 1.Ji thout an appropriate breathing apparatus.

Therefore, the primary containment is inerted as late as possible in the plant startup and de inerted as soon as possible in the plant shutdo 1.m.

/\\s long as reactor po 1.Jer is < 15?& RTP, the potential for an event that generates significant hydrogen and oxygen is l 0 1.J and the primary containment need not be inert.

Furthermore, the probability of an event that generates hydrogen occurring 1.Ji thin the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of a startup, or 1.Jithin the last 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> before a shutdo 1.m, is low enough that these 11 windO't*.'S, 11 when the primary containment is not inerted, are also justified.

The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> time period is a reasonable amount of time to allow plant personnel to perform inerting or de inerting.

If oxygen concentration is ~ 4.0 v/o at any time while operating in MODE 1 or 2, with the exception of the relaxations allo 1.Jed during startup and shutdo 1.m, oxygen concentration (continued)

B 3.6.3.1-2 Revision.Q.

BASES ACTIONS SURVEILLANCE REQUIREMENTS REFERENCES Dresden 2 and 3 Primary Containment Oxygen Concentration B 3.6.3.1 A......l (continued) must be restored to < 4.0 v/o within 72~ hours.

The 72~ hour Completion Time is allowed when oxygen concentration is~ 4.0 v/o because of the availability of other hydrogen and oxygen mitigating systems (e.g., post-accident nitrogen purge) and the low probability and long duration of an event that would generate significant amounts of hydrogen and oxygen occurring during this period.

A Note permits the use of the provisions of LCO 3.0.4.c.

This allowance permits entry into the applicable MODE(S) while relying on the ACTIONS.

This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus.

Therefore, the primary containment is inerted as late as possible in the plant startup, after entering Modes 1 and 2, and de-inerted as soon as possible in the plant shutdown.

It is acceptable to intentionally enter Required Action A.1 prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

If oxygen concentration cannot be restored to within limits within the required Completion Time, the plant must be brought to a MODE in which the LCO does not apply.

To a chi eve this status, po 1.Jer the plant must be reduced to

< 15% RTPplaced in MODE 3 within 12g hours.

The 12g hour Completion Time is reasonable, based on operating experience, to reduce reactor power from full power conditions in an orderly manner and without challenging plant systems.

SR 3.6.3.1.1 The primary containment must be determined to be inerted by verifying that oxygen concentration is< 4.0 v/o.

The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.

1.

Generic Letter 84-09, May 1984.

2.

UFSAR, Section 6.2.5.

B 3.6.3.1-3 Revision 9-

ATTACHMENT 3b LASALLE COUNTY STATION, UNITS 1AND2 DOCKET NOS. 50-373 AND 50-374 RENEWED FACILITY OPERATING LICENSE NOS. NPF-11 AND NPF-18 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 LaSalle Proposed Technical Specifications Bases Changes (for information only)

MARKED-UP TS BASES PAGES B 3.6.3.2-1 B 3.6.3.2-2 B 3.6.3.2-3

Primary Containment Oxygen Concentration B 3.6.3.2 B 3.6 CONTAINMENT SYSTEMS B 3.6.3.2 Primary Containment Oxygen Concentration BASES BACKGROUND APPLICABLE SAFETY ANALYSES LCO APPLICABILITY LaSalle 1 and 2 The primary containment is designed to withstand events that generate hydrogen either due to the zirconium metal water reaction in the core or due to radiolysis.

The primary method to control hydrogen is to inert the primary containment.

With the primary containment inerted, that is, oxygen concentration< 4.0 volume percent (v/o), a combustible mixture cannot be present in the primary containment for any hydrogen concentration.

An event that rapidly generates hydrogen from zirconium metal water reaction will result in excessive hydrogen in primary containment, but oxygen concentration will remain< 4.0 v/o and no combustion can occur.

This LCO ensures that oxygen concentration does not exceed 4.0 v/o during operation in the applicable conditions.

The Reference 1 calculations assume that the primary containment is inerted when a Design Basis Accident loss of coolant accident occurs.

Thus, the hydrogen assumed to be released to the primary containment as a result of metal water reaction in the reactor core will not produce combustible gas mixtures in the primary containment.

Primary containment oxygen concentration satisfies Criterion 2 of 10 CFR 50.36(c)(2)(ii ).

The primary containment oxygen concentration is maintained

< 4.0 v/o to ensure that an event that produces any amount of hydrogen does not result in a combustible mixture inside primary containment.

The primary containment oxygen concentration must be within the specified limit when primary containment is inerted, except as allowed by the relaxations during startup and shutdo 1.m addressed bel 0 1.J.

The primary containment must be inert in MODES 1 and 2, since this is the condition with the highest probability of an event that could produce hydrogen.

(continued)

B 3.6.3.2-1 Revision -+/-

BASES (continued)

/\\PPLIC/'dn LIT¥ (continued)

ACTIONS LaSalle 1 and 2 Primary Containment Oxygen Concentration B 3.6.3.2 Inerting the primary containment is an operational problem because it prevents containment access without an appropriate breathing apparatus.

Therefore, the primary containment is inerted as late as possible in the plant startup and de inerted as soon as possible in the plant shutdo 1.m.

/\\s long as reactor po 1o1er is < 15?6 RTP, the potential for an event that generates significant hydrogen is 10 1.J and the primary containment need not be inert.

Furthermore, the probability of an event that generates hydrogen occurring 1.Ji thin the first 2~ hours of a start up, or 1.Ji thin the last 2~ hours before a shutdo 1.m, is l 0 1.J enough that these 111... 'indows, 1' when the primary containment is not inerted, are also justified.

The 2~ hour time period is a reasonable amount of time to allow plant personnel to perform inerting or de inerting.

If oxygen concentration is ~ 4.0 v/o at any time while operating in MODE 1 or 2,

1.Ji th the exception of the relaxations allowed during startup and shutdown, oxygen concentration must be restored to < 4.0 v/o within 72-24 hours.

The 72-24 hour Completion Time is allowed when oxygen concentration is~ 4.0 v/o because the low probability and long duration of an event that would generate significant amounts of hydrogen occurring during this period.

A Note permits the use of the provisions of LCO 3.0.4.c.

This allowance permits entry into the applicable MODE(S) while relying on the ACTIONS.

This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus.

Therefore, the primary containment is inerted as late as possible in the plant startup and de-inerted as soon as possible in the plant shutdown.

It is acceptable to intentionally enter Required Action A.1 prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

Similarly, intentional entry into Required Action A.1 during startup conditions is acceptable per Technical Specification 3.0.4.c.

(continued)

B 3.6.3.2-2 Revision -+/-

BASES ACTIONS (continued)

SURVEILLANCE REQUIREMENTS REFERENCES LaSalle 1 and 2 Primary Containment Oxygen Concentration B 3.6.3.2 If oxygen concentration cannot be restored to within limits within the required Completion Time, the plant must be brought to a MODE in which the LCO does not apply.

To achieve this status, power the plant must be reduced to

< 15% RTPplaced in MODE 3 within 12g hours.

The 12g hour Completion Time is reasonable, based on operating experience, to reduce reactor power from full power conditions in an orderly manner and without challenging plant systems.

SR 3.6.3.2.l The primary containment must be determined to be inerted by verifying that oxygen concentration is< 4.0 v/o.

The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.

1.

UFSAR, Section 6.2.5.

B 3.6.3.2-3 Revision M

ATTACHMENT 3c LIMERICK GENERATING STATION, UNITS 1AND2 DOCKET NOS. 50-352 AND 50-353 RENEWED FACILITY OPERATING LICENSE NOS. NPF-39 AND NPF-85 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Limerick Proposed Technical Specifications Bases Changes (for information only)

MARKED-UP TS BASES PAGES B 3/4 6-7 (Unit 1)

B 3/4 6-7 (Unit 2)

CONTAINMENT SYSTEMS 314.6.6 PRIMARY CONTAINMENT ATMOSPHERE CONTROL (Continued)

If oxygen concentration is~ 4.0 via while operating in OPERATIONAL CONDITION 1 or 2, oxygen concentration must be restored to< 4.0 via within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. The 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Completion Time is allowed when oxygen concentration is~ 4.0 via because of the low probability and long duration of an event that would generate significant amounts of hydrogen occurring during this period.

The provision of Specification 3.0.4.c is applicable. This allowance permits entry into the applicable OPERATIONAL CONDITION(S) while relying on the Actions. This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus. Therefore, the primary containment is inerted as late as possible in the plant startup, after entering OPERATIONAL CONDITIONS 1 and 2, and de-inerted as soon as possible in the plant shutdown. It is acceptable to intentionally enter the Action prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

If oxygen concentration cannot be restored to within the limit within the required Completion Time, the plant must be brought to an OPERATIONAL CONDITION in which the LCD does not apply. To achieve this status, the plant must be placed in HOT SHUTDOWN within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. The 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Completion Time is reasonable, based on operating experience, to reduce reactor power from full power conditions in an orderly manner and without challenging plant systems.

LIMERICK - UNIT 1 B 314 6-7 Amendment No.

CONTAINMENT SYSTEMS BA E 3/4.6.6 PRIMARY CONTAINMENT ATMOSPHERE CONTROL The primary containment atmospheric mixing system is provided to ensure adequate mixing of the containment atmosphere to prevent localized accumulations of hydrogen and oxygen from exceeding the lower flammability limit during post-LOCA conditions.

All nuclear reactors must be designed to withstand events that generate hydrogen either due to the zirconium metal water reaction in the core or due to radiolysis.

The primary method to control hydrogen is to inert the primary containment.

With the primary containment inert, that is, oxygen concentration <4.0 volume percent (v/o), a combustible mixture cannot be present in the primary containment for any hydrogen concentration.

The capability to inert the primary containment and maintain oxygen <4.0 v/o works together with Drywell Hydrogen Mixing System to provide redundant and diverse methods to mitigate events that produce hydrogen.

If oxygen concentration is~ 4.0 vlo while operating in OPERATIONAL CONDITION 1 or 2, oxygen concentration must be restored to< 4.0 vlo within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. The 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Completion Time is allowed when oxygen concentration is~ 4.0 vlo because of the low probability and long duration of an event that would generate significant amounts of hydrogen occurring during this period.

The provision of Specification 3.0.4.c is applicable. This allowance permits entry into the applicable OPERATIONAL CONDITION(S) while relying on the Actions. This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus. Therefore, the primary containment is inerted as late as possible in the plant startup, after entering OPERATIONAL CONDITIONS 1 and 2, and de-inerted as soon as possible in the plant shutdown. It is acceptable to intentionally enter the Action prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

If oxygen concentration cannot be restored to within the limit within the required Completion Time, the plant must be brought to an OPERATIONAL CONDITION in which the LCD does not apply. To achieve this status, the plant must be placed in HOT SHUTDOWN within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. The 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Completion Time is reasonable, based on operating experience, to reduce reactor power from full power conditions in an orderly manner and without challenging plant systems.

LIMERICK - UNIT 2 8 3/4 6-7 Amendment No.

ECR 00 00132, ~

ATTACHMENT 3d NINE MILE POINT, UNIT2 DOCKET NO. 50-410 RENEWED FACILITY OPERATING LICENSE NO. NPF-69 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Nine Mile Point Proposed Technical Specifications Bases Changes (for information only)

MARKED-UP TS BASES PAGES B 3.6.3.2-2 B 3.6.3.2-3

BASES (continued)

LCO APPLICABILITY ACTIONS NMP2 Primary Containment Oxygen Concentration B 3.6.3.2 The primary containment oxygen concentration is maintained

< 4.0 v/o to ensure that an event that produces any amount of hydrogen and oxygen does not result in a combustible mixture inside primary containment.

The primary containment oxygen concentration must be within the specified limit when primary containment is inerted, except as allowed by the relaxations during startup and shutdown addressed below. The primary containment must be inert in MODES 1 and 2, since this is the condition with the highest probability of an event that could produce hydrogen and oxygen.

lnerting the primary containment is an operational problem because it prevents containment access without an appropriate breathing apparatus. Therefore, the primary containment is inerted as late as possible in the plant startup and de inerted as soon as possible in the plant shutdown. As long as reactor power is< 15% RTP, the potential for an event that generates significant hydrogen and oxygen is low and the primary containment need not be inert. Furthermore, the probability of an event that generates hydrogen occurring within the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of a startup, or within the last 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> before a shutdown, is low enough that these "windows," when the primary containment is not inerted, are also justified. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> time period is a reasonable amount of time to allow plant personnel to perform inerting or de inerting.

A.1 If oxygen concentration is z 4.0 v/o at any time while operating in MODE 1 or 2, with the exception of the relaxations allowed during startup and shutdown, oxygen concentration must be restored to < 4.0 v/o within 72~ hours. The 72~ hour Completion Time is allowed when oxygen concentration is z 4.0 v/o because of the low probability and long duration of an event that would generate significant amounts of hydrogen and oxygen occurring during this period.

(continued)

B 3.6.3.2-2 Revision 0, 25 (A124)

BASES ACTIONS SURVEILLANCE REQUIREMENTS REFERENCES NMP2 Primary Containment Oxygen Concentration B 3.6.3.2 A.1 (continued)

A Note permits the use of the provisions of LCO 3.0.4.c. This allowance permits entry into the applicable MODE(S) while relying on the ACTIONS. This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus. Therefore, the primary containment is inerted as late as possible in the plant startup, after entering Modes 1 and 2, and de-inerted as soon as possible in the plant shutdown. It is acceptable to intentionally enter Required Action A. 1 prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

If oxygen concentration cannot be restored to within limits within the required Completion Time, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plantf3GWef must be placed inreduced to MODE 3< 15% RTP within 12g hours. The 12g hour Completion Time is reasonable, based on operating experience, to reduce reactor power from full power conditions in an orderly manner and without challenging plant systems.

SR 3.6.3.2.1 The primary containment must be determined to be inerted by verifying that oxygen concentration is < 4.0 v/o. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.

1.

USAR, Section 6.2.5.

2.

10 CFR 50.36(c)(2)(ii).

B 3.6.3.2-3 Revision 0, 44 (A152)

ATTACHMENT 3e PEACH BOTTOM ATOMIC POWER STATION, UNITS 2 AND 3 DOCKET NOS. 50-277 AND 50-278 SUBSEQUENT RENEWED FACILITY OPERATING LICENSE NOS. DPR-44 AND DPR-56 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Peach Bottom Proposed Technical Specifications Bases Changes (for information only}

MARKED-UP TS BASES PAGES X.Y-Z

BASES (continued)

Primary Containment Oxygen Concentration 8 3.6.3.2 LCO The primary containment oxygen concentration is maintained APPLICABILITY ACTIONS PBAPS UN IT 2

< 4.0 v/o to ensure that an event that produces any amount of hydrogen does not result in a combustible mixture inside primary containment.

The primary containment oxygen concentration must be within the specified limit when primary containment is inerted,.

The primary containment must be inert in MODES 1 and 2, since this is the condition with the highest probability of an event that could produce hydrogen.

Inerting the primary containment is an operational problem because it prevents containment access without an appropriate breathing apparatus.

Therefore, the primary containment is inerted as late as possible in the plant startup and de inerted as soon as possible in the plant shutdown.

As long as reactor power is< 15% RTP, the potential for an event that generates significant hydrogen is low and the primary containment need not be inert.

Furthermore, the probability of an event that generates hydrogen occurring within the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of a startup, or within the last 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> before a shutdown, is low enough that these "windows," when the primary containment is not inerted, are also justified.

The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> time period is a reasonable amount of time to allow plant personnel to perform inerting or de inerting.

If oxygen concentration is ~ 4.0 v/o at any time while operating in MODE 1 or 2, with the exception of the relaxations allowed during startup and shutdown, oxygen concentration must be restored to < 4.0 v/o within 7224 hours0.0836 days <br />2.007 hours <br />0.0119 weeks <br />0.00275 months <br />.

The 7224 hour0.0836 days <br />2.007 hours <br />0.0119 weeks <br />0.00275 months <br /> Completion Time is allowed when oxygen concentration is~ 4.0 v/o because of the availability of other hydrogen mitigating systems (e.g., the CAD System) and the low probability and long duration of an event that would generate significant amounts of hydrogen occurring during this period.

continued 8 3.6-71 Revision No..Q.

BASES ACTIONS SURVEILLANCE REQUIREMENTS REFERENCES PBAPS UN IT 2 A.l (continued)

Primary Containment Oxygen Concentration B 3.6.3.2 A Note permits the use of the prov1s1ons of LCO 3.0.4.c. This allowance permits entry into the applicable MODE(S) while relying on the ACTIONS. This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus. Therefore, the primary containment is inerted as late as possible in the plant startup and de-inerted as soon as possible in the plant shutdown. It is acceptable to intentionally enter Required Action A.l prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

If oxygen concentration cannot be restored to within limits within the required Completion Time, the plant must be brought to a MODE in which the LCO does not apply.

To achieve this status, the plantfJ-8-W-e-f-must be placed inreduced to MODE 3

< 15% RTP within 12g hours.

The 12g hour Completion Time is reasonable, based on operating experience, to reduce reactor power from full power conditions in an orderly manner and without challenging plant systems.

SR 3.6.3.2.1 The primary containment (drywell and suppression chamber) must be determined to be inert by verifying that oxygen concentration is< 4.0 v/o.

The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.

1.

UFSAR, Section 5.2.3.9.5.

B 3.6-72 Revision No. oo

BASES (continued)

Primary Containment Oxygen Concentration 8 3.6.3.2 LCO The primary containment oxygen concentration is maintained APPLICABILITY ACTIONS PBAPS UN IT 3

< 4.0 v/o to ensure that an event that produces any amount of hydrogen does not result in a combustible mixture inside primary containment.

The primary containment oxygen concentration must be within the specified limit when primary containment is inerted, except as allowed by the relaxations during startup and shutdown addressed below.

The primary containment must be inert in MODES 1 and 2, since this is the condition with the highest probability of an event that could produce hydrogen.

Inerting the primary containment is an operational problem because it prevents containment access without an appropriate breathing apparatus.

Therefore, the primary containment is inerted as late as possible in the plant startup and de inerted as soon as possible in the plant shutdown.

As long as reactor power is< 15% RTP, the potential for an event that generates significant hydrogen is low and the primary containment need not be inert.

Furthermore, the probability of an event that generates hydrogen occurring within the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of a startup, or within the last 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> before a shutdown, is low enough that these "windows," when the primary containment is not inerted, are also justified.

The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> time period is a reasonable amount of time to allow plant personnel to perform inerting or de inerting.

If oxygen concentration is ~ 4.0 v/o at any time while operating in MODE 1 or 2, with the exception of the relaxations allowed during startup and shutdown, oxygen concentration must be restored to < 4.0 v/o within 7224 hours0.0836 days <br />2.007 hours <br />0.0119 weeks <br />0.00275 months <br />. The 7224 hour0.0836 days <br />2.007 hours <br />0.0119 weeks <br />0.00275 months <br /> Completion Time is allowed when oxygen concentration is~ 4.0 v/o because of the availability of other hydrogen mitigating systems (e.g., the CAD System) and the low probability and long duration of an event that would generate significant amounts of hydrogen occurring during this period.

(continued) 8 3.6-71 Revision No..Q.

BASES ACTIONS SURVEILLANCE REQUIREMENTS REFERENCES PBAPS UN IT 3 A.1 (continued)

Primary Containment Oxygen Concentration 8 3.6.3.2 A Note permits the use of the prov1s1ons of LCO 3.0.4.c. This allowance permits entry into the applicable MODE(S) while relying on the ACTIONS. This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus.

Therefore, the primary containment is inerted as late as possible in the plant startup and de-inerted as soon as possible in the plant shutdown. It is acceptable to intentionally enter Required Action A.l prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

If oxygen concentration cannot be restored to within limits within the required Completion Time, the plant must be brought to a MODE in which the LCO does not apply.

To achieve this status, the plantfJ-8-W-e-f-must be placed inreduced to MODE 3

< 15% RTP within 12g hours.

The 12g hour Completion Time is reasonable, based on operating experience, to reduce reactor power from full power conditions in an orderly manner and without challenging plant systems.

SR 3.6.3.2.1 The primary containment (drywell and suppression chamber) must be determined to be inert by verifying that oxygen concentration is< 4.0 v/o.

The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.

1.

UFSAR, Section 5.2.3.9.5.

8 3.6-72 Revision No..g.+

ATTACHMENT 3f QUAD CITIES NUCLEAR STATION, UNITS 1AND2 DOCKET NOS. 50-254 AND 50-265 RENEWED FACILITY OPERATING LICENSE NOS. DPR-29 AND DPR-30 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Quad Cities Proposed Technical Specifications Bases Changes (for information only)

MARKED-UP TS BASES PAGES B 3.6.2.5-2 B 3.6.2.5-3 B 3.6.3.1-2 B 3.6.3.1-3

BASES LCO (continued)

APPLICABILITY ACTIONS Drywell-to-Suppression Chamber Differential Pressure B 3.6.2.5 drywell-to-suppression chamber differential pressure of

< 1.0 psid corresponds to a downcomer water leg of approximately 1 ft.

Failure to maintain the required differential pressure could result in excessive forces on the suppression chamber due to higher water clearing loads from downcomer vents and higher pressure buildup in the d rywe 11.

A Note is provided to allow for periods of up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> when the LCO is not required to be met during the performance of required Surveillances that reduce the differential pressure.

The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> time is acceptable since the probability of a DBA LOCA occurring during this time is

+B-w.-

Drywell-to-suppression chamber differential pressure must be controlled when the primary containment is inert.

The primary containment must be inert in MODE 1 with THERMAL POWER> 15% RTP, since this is the condition with the highest probability for an event that could produce hydrogen.

It is also the condition with the highest probability of an event that could impose large loads on the primary containment.

Inerting primary containment is an operational problem because it prevents primary containment access without an appropriate breathing apparatus.

Therefore, the primary containment is inerted as late as possible in the unit startup and is de inerted as soon as possible in the unit shutdo 1.m.

As long as reactor po 1o1er is E 15?b RTP, the probability of an event that generates hydrogen or excessive loads on primary containment occurring 1.Jithin the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> following a startup or within the last 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to a shutdo 1.m is l 0 1.J enough that these 111t.1indows, 1' with the primary containment not inerted, are also justified.

The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> time period is a reasonable amount of time to allow plant personnel to perform inerting or de inerting.

If drywell-to-suppression chamber differential pressure is not within the limit, the conditions assumed in the safety analyses are not met and the differential pressure must be restored to within the limit within 72~ hours.

The 72~ hour Completion Time provides sufficient time to restore (continued)

Quad Cities 1 and 2 B 3.6.2.5-2 Revision.Q.

BASES ACTIONS SURVEILLANCE REQUIREMENTS REFERENCES Drywell-to-Suppression Chamber Differential Pressure B 3.6.2.5 A......l (continued) differential pressure to 1.Jithin limit and takes into account the low probability of an event that would create excessive suppression chamber loads occurring during this time period.

A Note permits the use of the provisions of LCD 3.0.4.c.

This allowance permits entry into the applicable MODE(S) while relying on the ACTIONS.

This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus.

Therefore, the primary containment is inerted as late as possible in the plant startup, after entering Mode 1 with THERMAL POWER> 15% RTP, and de-inerted as soon as possible in the plant shutdown.

It is acceptable to intentionally enter Required Action A.1 prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

If the differential pressure cannot be restored to within limits within the associated Completion Time, the plant must be placed in a MODE in which the LCO does not apply.

This is done by reducing power to~ 15% RTP within 12g hours.

The 12g hour Completion Time is reasonable, based on operating experience, to reduce reactor power from full power conditions in an orderly manner and without challenging plant systems.

SR 3.6.2.5.l The drywell-to-suppression chamber differential pressure is regularly monitored to ensure that the required limits are satisfied.

The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.

None.

Quad Cities 1 and 2 B 3.6.2.5-3 Revision 4-J

BASES APPLICABLE SAFETY ANALYSES (continued)

LCO APPLICABILITY ACTIONS Primary Containment Oxygen Concentration B 3.6.3.1 combustible gas mixtures in the primary containment.

Oxygen, which is subsequently generated by radiolytic decomposition of water, will not result in the primary containment becoming de-inerted within the first 30 days following an accident.

Primary containment oxygen concentration satisfies 10 CFR 50.36(c)(2)(ii).

The primary containment oxygen concentration is maintained

< 4.0 v/o to ensure that an event that produces any amount of hydrogen and oxygen does not result in a combustible mixture inside primary containment.

The primary containment oxygen concentration must be within the specified limit when primary containment is inerted, except as allo 1.Jed by the relaxations during startup and shutdown addressed below.

The primary containment must be inert in MODES 1 and 2, since this is the condition with the highest probability of an event that could produce hydrogen and oxygen.

Inerting the primary containment is an operational problem because it prevents containment access 1.Ji thout an appropriate breathing apparatus.

Therefore, the primary containment is inerted as late as possible in the plant startup and de inerted as soon as possible in the plant shutdo 1.m.

/\\s long as reactor po 1.Jer is < 15?& RTP, the potential for an event that generates significant hydrogen and oxygen is l 0 1.J and the primary containment need not be inert.

Furthermore, the probability of an event that generates hydrogen occurring 1.Ji thin the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of a startup, or 1.Jithin the last 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> before a shutdo 1.m, is low enough that these 11 windO't*.'S, 11 when the primary containment is not inerted, are also justified.

The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> time period is a reasonable amount of time to allow plant personnel to perform inerting or de inerting.

If oxygen concentration is ~ 4.0 v/o at any time while operating in MODE 1 or 2, with the exception of the relaxations allo 1.Jed during startup and shutdo 1.m, oxygen concentration (continued)

Quad Cities 1 and 2 B 3.6.3.1-2 Revision.Q.

BASES ACTIONS SURVEILLANCE REQUIREMENTS REFERENCES A......l (continued)

Primary Containment Oxygen Concentration B 3.6.3.1 must be restored to< 4.0 v/o within 72~ hours.

The 72~ hour Completion Time is allowed when oxygen concentration is~ 4.0 v/o because of the availability of other hydrogen and oxygen mitigating systems (e.g., post-accident nitrogen purge) and the low probability and long duration of an event that would generate significant amounts of hydrogen and oxygen occurring during this period.

A Note permits the use of the provisions of LCO 3.0.4.c.

This allowance permits entry into the applicable MODE(S) while relying on the ACTIONS.

This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus.

Therefore, the primary containment is inerted as late as possible in the plant startup, after entering Modes 1 and 2, and de-inerted as soon as possible in the plant shutdown.

It is acceptable to intentionally enter Required Action A.1 prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

If oxygen concentration cannot be restored to within limits within the required Completion Time, the plant must be brought to a MODE in which the LCO does not apply.

To achieve this status, power the plant must be placed in MODE 3 reduced to < 15% RTP within 12g hours.

The 12g hour Completion Time is reasonable, based on operating experience, to reduce reactor power from full power conditions in an orderly manner and without challenging plant systems.

SR 3.6.3.1.1 The primary containment must be determined to be inerted by verifying that oxygen concentration is< 4.0 v/o.

The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.

1.

Generic Letter 84-09, May 1984.

2.

UFSAR, Section 6.2.5.

Quad Cities 1 and 2 B 3.6.3.1-3 Revision 4-J

ATTACHMENT 4a DRESDEN NUCLEAR POWER STATION, UNITS 2 AND 3 DOCKET NOS. 50-237 AND 50-249 RENEWED FACILITY OPERATING LICENSE NOS. DPR-19 AND DPR-25 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Dresden Technical Specifications Changes REVISED (CLEAN) TS PAGES 3.6.2.5-1 3.6.3.1-1

Drywell-to-Suppression Chamber Differential Pressure 3.6.2.5 3.6 CONTAINMENT SYSTEMS 3.6.2.5 Drywell-to-Suppression Chamber Differential Pressure LCO 3.6.2.5 The drywell pressure shall be maintained~ 1.0 psid above the pressure of the suppression chamber.

APPLICABILITY:

MODE 1 with THERMAL POWER > 15% RTP.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

Drywel 1-to-suppressi on A.1

- - - - - - - -NOTE- - - - - - - -

chamber differential LCO 3.0.4.c is pressure not within appl i cable limit.

Restore differential 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> pressure to within l i mit.

B.

Required Action and 8.1 Reduce THERMAL POWER 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion to ~ 15% RTP.

Time not met.

Dresden 2 and 3 3.6.2.5-1 Amendment No.

Primary Containment Oxygen Concentration 3.6.3.1 3.6 CONTAINMENT SYSTEMS 3.6.3.1 Primary Containment Oxygen Concentration LCO 3.6.3.1 The primary containment oxygen concentration shall be

< 4.0 volume percent.

APPLICABILITY:

MODES 1 and 2.

ACTIONS CONDITION REQUIRED ACTION A.

Primary containment A.1

- - - - - - - -NOTE- - - - - - - -

oxygen concentration LCO 3.0.4.c is not within l i mit.

applicable Restore oxygen concentration to within limit.

B.

Required Action and B.1 Be in MODE 3.

associated Completion Time not met.

SURVEILLANCE REQUIREMENTS SURVEILLANCE SR 3.6.3.1.1 Verify primary containment oxygen concentration is within limits.

COMPLETION TIME 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> 12 hours FREQUENCY In accordance with the Survei 11 ance Frequency Control Program Dresden 2 and 3 3.6.3.1-1 Amendment No.

ATTACHMENT 4b LASALLE COUNTY STATION, UNITS 1AND2 DOCKET NOS. 50-373 AND 50-374 RENEWED FACILITY OPERATING LICENSE NOS. NPF-11 AND NPF-18 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 LaSalle Proposed Technical Specifications Changes REVISED (CLEAN) TS PAGES 3.6.3.2-1

Primary Containment Oxygen Concentration 3.6.3.2 3.6 CONTAINMENT SYSTEMS 3.6.3.2 Primary Containment Oxygen Concentration LCO 3.6.3.2 The primary containment oxygen concentration shall be

< 4.0 vo lume percent.

APPLICABILITY:

MODES 1 and 2.

ACTIONS CONDITION REQUIRED ACTION A.

Primary containment A.1

- - - - - - - -NOTE- - - - - - - -

oxygen concentrat ion LCO 3.0.4.c is not within limit.

appl i cable Restore oxygen concentration to within limit.

B.

Required Action and B.l Be in MODE 3.

associated Completion Time not met.

SURVEILLANCE REQUIREMENTS SURVEILLANCE SR 3.6.3.2.1 Verify primary containment oxygen concentration is within limits.

COMPLETION TIME 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> 12 hours FREQUENC Y In accordance with the Surveillance Frequency Control Program LaSalle 1 and 2 3.6.3.2-1 Amendment No.

ATTACHMENT 4c LIMERICK GENERATING STATION, UNITS 1AND2 DOCKET NOS. 50-352 AND 50-353 RENEWED FACILITY OPERATING LICENSE NOS. NPF-39 AND NPF-85 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Limerick Proposed Technical Specifications Changes REVISED (CLEAN) TS PAGES 3/4 6-59 (Unit 1) 3/4 6-59 (Unit 2)

CONTAINMENT SYSTEMS DRYWELL AND SUPPRESSION CHAMBER OXYGEN CONCENTRATION LIMITING CONDITION FOR OPERATION 3.6.6.3 The drywell and suppression chamber atmosphere oxygen concentration shall be less than 4% by volume.

APPLICABILITY:

OPERATIONAL CONDITIONS l* and 2.

ACTION:

With the drywell and/or suppression chamber oxygen concentration exceeding the limit, restore the oxygen concentration to within the limit within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. The provision of Specification 3.0.4.c is applicable.

SURVEILLANCE REQUIREMENTS 4.6.6.3 The drywell and suppression chamber oxygen concentration shall be verified to be within the limit in accordance with the Surveillance Frequency Control Program.

  • See Special Test Exception 3.10.5.

LIMERICK - UNIT 1 3/4 6-59 Amendment No. -+/-.ge

CONTAINMENT SYSTEMS DRYWELL AND SUPPRESSION CHAMBER OXYGEN CONCENTRATION LIMITING CONDITION FOR OPERATION 3.6.6.3 The drywell and suppression chamber atmosphere oxygen concentration shall be less than 4% by volume.

APPLICABILITY:

OPERATIONAL CONDITIONS 1* and 2.

ACTION:

With the drywell and/or suppression chamber oxygen concentration exceeding the limit, restore the oxygen concentration to within the limit within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

The provision of Specification 3.0.4.c is applicable.

SURVEILLANCE REQUIREMENTS 4.6.6.3 The drywell and suppression chamber oxygen concentration shall be verified to be within the limit in accordance with the Surveillance Frequency Control Program.

  • See Special Test Exception 3.10.5.

LIMERICK - UNIT 2 3/4 6-59 Amendment No. -+/-4-+

ATTACHMENT 4d NINE MILE POINT, UNIT2 DOCKET NO. 50-410 RENEWED FACILITY OPERATING LICENSE NO. NPF-69 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Nine Mile Point Proposed Technical Specifications Changes REVISED (CLEAN) TS PAGES 3.6.3.2-1

Primary Containment Oxygen Concentration 3.6.3.2 3.6 CONTAINMENT SYSTEMS 3.6.3.2 Primary Containment Oxygen Concentration LCO 3.6.3.2 The primary containment oxygen concentration shall be

< 4.0 volume percent.

APPLICABILITY:

MODES 1 and 2.

ACTIONS CONDITION REQUIRED ACTION A.

Primary containment A.1


N 0 TE-----------

oxygen concentration LCO 3.0.4.c is not within limit.

applicable.

Restore oxygen concentration to within limit.

B.

Required Action and B.1 Be in MODE 3 associated Completion Time not met.

SURVEILLANCE REQUIREMENTS SURVEILLANCE SR 3.6.3.2.1 NMP2 Verify primary containment oxygen concentration is within limits.

3.6.3.2-1 COMPLETION TIME 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> 12 hours FREQUENCY In accordance with the Surveillance Frequency Control Program Amendment 94-, ~

ATTACHMENT 4e PEACH BOTTOM ATOMIC POWER STATION, UNITS 2 AND 3 DOCKET NOS. 50-277 AND 50-278 SUBSEQUENT RENEWED FACILITY OPERATING LICENSE NOS. DPR-44 AND DPR-56 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Peach Bottom Proposed Technical Specifications Changes REVISED (CLEAN) TS PAGES X.Y-Z

Primary Containment Oxygen Concentration 3.6.3.2 3.6 CONTAINMENT SYSTEMS 3.6.3.2 Primary Containment Oxygen Concentration LCO 3.6.3.2 The primary containment oxygen concentration shall be

< 4.0 volume percent.

APPLICABILITY:

MODES 1 and 2.

ACTIONS CONDITION REQUIRED ACTION A.

Primary containment A.1

- - - - - - - -NOTE- - - - - - - - -

oxygen concentration LCO 3.0.4.c is not within limit.

applicable.

Restore oxygen concentration to limit.

B.

Required Action and B.1 Be in MODE 3.

associated Completion Time not met.

SURVEILLANCE REQUIREMENTS SURVEILLANCE SR 3.6.3.2.1 Verify primary containment oxygen concentration is within limits.

PBAPS UN IT 2 3.6-33 within COMPLETION TIME 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> 12 hours FREQUENCY In accordance with the Surveillance Frequency Control Program.

Amendment No.

Primary Containment Oxygen Concentration 3.6.3.2 3.6 CONTAINMENT SYSTEMS 3.6.3.2 Primary Containment Oxygen Concentration LCO 3.6.3.2 The primary containment oxygen concentration shall be

< 4.0 volume percent.

APPLICABILITY:

MODES 1 and 2.

ACTIONS CONDITION REQUIRED ACTION A.

Primary containment A.1

- - - - - - - -NOTE- - - - - - - - -

oxygen concentration LCO 3.0.4.c is not within limit.

applicable.

Restore oxygen concentration to limit.

B.

Required Action and B.1 Be in MODE 3.

associated Completion Time not met.

SURVEILLANCE REQUIREMENTS SURVEILLANCE SR 3.6.3.2.1 Verify primary containment oxygen concentration is within limits.

PBAPS UN IT 3 3.6-33 within COMPLETION TIME 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> 12 hours FREQUENCY In accordance with the Surveillance Frequency Control Program.

Amendment No.

ATTACHMENT 4f QUAD CITIES NUCLEAR STATION, UNITS 1AND2 DOCKET NOS. 50-254 AND 50-265 RENEWED FACILITY OPERATING LICENSE NOS. DPR-29 AND DPR-30 REQUEST FOR TECHNICAL SPECIFICATION CHANGE RELATED TO THE ADOPTION OF TSTF-568 Quad Cities Proposed Technical Specifications Changes REVISED (CLEAN) TS PAGES 3.6.2.5-1 3.6.3.1-1

Drywell -t o-Suppress i on Chamber Differenti al Pressure 3.6.2. 5 3.6 CONTAI NM ENT SYSTE MS 3.6.2. 5 Drywell -t o-Suppress i on Chamber Di fferen ti al Pressure LCO 3.6.2. 5 The drywe ll pressure sha ll be ma i n t a i ned~ 1.0 ps i d above t he pressure of t he suppress i on chamber.

APP LI CAB ILITY:

MOD E 1 wit h THE RMA L POW ER> 15% RTP.

ACTI ONS COND IT ION REQUIR ED ACTI ON COM PLETION TI ME A.

Drywe l 1-t o-suppress i on A.1

- - - - - - - -NOTE - - - - - - - -

chamber di fferent i al LCO 3.0.4.c is pressure no t wit hi n app l i cab l e li mit.

Restore different i al 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> pressure to withi n li mit.

B.

Required Ac t ion and B.l Reduce THERMA L POW ER 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> assoc i at ed Comp l eti on to ~ 15% RTP.

Ti me no t met.

Quad Citi es 1 and 2 3.6.2.5 -1 Amendmen t No.

Pr imary Con t ai nmen t Oxygen Concen t ra ti on 3.6.3.1 3.6 CONTAI NM ENT SYSTE MS 3.6.3.1 Pr imary Con t ai nmen t Oxygen Concentra ti on LCO 3.6.3.1 The pr imary con t ai nmen t oxygen concen t ra ti on shall be

< 4.0 vo l ume percent.

APP LI CAB ILITY:

MOD ES 1 and 2.

ACTI ONS COND IT ION REQUIR ED ACTI ON A.

Pr imary conta i nmen t A.1

- - - - - - - -NOTE - - - - - - - -

oxygen concentration LCO 3.0.4.c is not wi th i n li mit.

app l i cab l e Restore oxygen concen t ra ti on t o wi th i n li mi t.

B.

Requ i red Act i on and B.1 Be i n MOD E 3.

assoc i at ed Comp l eti on Time not met.

SURV EILLANC E REQU IREMENTS SURV EILLANC E SR 3.6.3. 1.1 Ver i fy pr imary con t ai nment oxygen concentrat i on i s wi t hi n li mits.

COM PLETION TI ME 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> 12 hours FREQUENCY In accordance with t he Surve i llance Frequency Control Program Quad Citi es 1 and 2 3.6.3. 1-1 Amendmen t No.