RS-13-171, Registration of Use of Cask to Store Spent Fuel

From kanterella
(Redirected from RS-13-171)
Jump to navigation Jump to search
Registration of Use of Cask to Store Spent Fuel
ML13193A058
Person / Time
Site: Limerick  
Issue date: 07/11/2013
From: Simpson P
Exelon Generation Co
To:
Document Control Desk, NRC/NMSS/SFST
References
RS-13-171
Download: ML13193A058 (3)


Text

n 10 CFR 72.212 RS-13-171 July 11,2013 ATTN: Document Control Desk Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 Limerick Generating Station, Units 1 and 2 Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352, 50-353, and 72-065

Subject:

Registration of Use of Cask to Store Spent Fuel In accordance with 10 CFR 72.212, "Conditions of general license issued under §72.210,"

paragraph (b)(2), Exelon Generation Company, LLC (EGC) is registering, with the NRC, the use of three casks under the general license to store spent fuel at Limerick Generating Station (LGS). The casks were placed into service with stored spent fuel on June 15, 2013, June 21, 2013, and June 28, 2013, respectively. This registration is required to be submitted within 30 days. Accordingly, this submittal is due by July 15, 2013.

The following information is provided in accordance with 10 CFR 72.212(b)(2).

Licensee Name:

Exelon Generation Company, LLC Licensee Address:

Limerick Generating Station 3146 Sanatoga Road Pottstown, PA 19464 Reactor License Numbers:

NPF-39 and NPF-85 Reactor Docket Numbers:

50-352, 50-353 Independent Spent Fuel Storage Installation Docket Number:

72-065 Contact Name and

Title:

P. R. Simpson Manager - Licensing

July 11,2013 U. S. Nuclear Regulatory Commission Page 2 Cask Certificate Number:

Cask Model Number:

HSM Model Number:

Service Date:

Cask Identification Number:

HSM Identification Number:

Service Date:

Cask Identification Number:

HSM Identification Number:

Service Date:

Cask Identification Number:

HSM Identification Number:

1004, Amendment 10 NUHOMS-61 BTH HSM 202 June 152013 LGS-61 BTH-1 -C-2-023 HSM-005 June 21, 2013 LGS-61 BTH-1-C-2-022 HSM-003 June 28 2013 LGS-61 BTH-1-C-2-021 HSM-001 In addition, this letter provides the results of the thermal performance assessment of the first Dry Storage Canister (DSC) placed into service. This information is required by Certificate of Compliance (CoC) No. 1004, Amendment No.10, Attachment A, "Technical Specifications" (TS) 1.1.7, "Special Requirements for First System in Place."

TS 1.1.7 also requires the submittal of the same information for subsequently loaded DSCs with higher heat loads. The attachment to this letter provides the information required by TS 1.1.7 for the three DSCs listed above. This information was obtained using LGS procedure ST-6-114-360-0, "Independent Spent Fuel Storage Installation (ISFSI) Technical Specification Testing."

Should you have any questions, please contact Mr. John L. Schrage at (630) 657-2821.

Attachment:

Thermal Performance Assessment Data, Limerick Generating Station, Independent Spent Fuel Storage Installation, 2013 Dry Cask Storage Campaign cc:

NRC Regional Administrator - Region I

Attachment Thermal Performance Assessment Data Limerick Generating Station Independent Spent Fuel Storage Installation 2013 Dry Cask Storage Campaign Dry Storage Canister Number LGS-61 BTH-1 -C-2-023 Horizontal Storage Module Number HSM-005 Maximum Allowable Heat Load 19.40 kW Actual Loaded Heat Load 14.10 kW Calculated Temperature Rise 44.000 F Measured Temperature Rise 23.40° F Dry Storage Canister Number LGS-61 BTH1-C-2-022 Horizontal Storage Module Number HSM-003 Maximum Allowable Heat Load 19.40 kW Actual Loaded Heat Load 14.46 kW Calculated Temperature Rise 45.00° F Measured Temperature Rise 13.95° F Dry Storage Canister Number LGS-61BTH1-C-2-021 Horizontal Storage Module Number HSM-001 Maximum Allowable Heat Load 19.40 kW Actual Loaded Heat Load 14.54 kW Calculated Temperature Rise 45.00° F Measured Temperature Rise 39.60° F