RS-11-100, Dresden, Units 2 and 3, Updated Final Safety Analysis Report (Ufsar), Revision 9, Chapter 15.0, Accident and Transient Analysis

From kanterella
Jump to navigation Jump to search
Dresden, Units 2 and 3, Updated Final Safety Analysis Report (Ufsar), Revision 9, Chapter 15.0, Accident and Transient Analysis
ML11202A195
Person / Time
Site: Dresden  Constellation icon.png
Issue date: 06/29/2011
From:
Exelon Generation Co, Exelon Nuclear
To:
NRC/FSME
References
RS-11-100
Download: ML11202A195 (216)


Text

DRESDEN - UFSAR Rev. 7 June 2007 Figure 15.6-4: Layout of Intakes and Release Points N Station Chimney UNIT 3REACTO R UNIT 2 BUILDING TURBINE UNIT 3 MSIV Room BUILDING UNIT 2MSIV Room CR Intake 11RADWASTE BUILDING DBA Release PathsLOCA Station chimney and MSIV room CRDA Station chimney and MSIV room FHA Reactor building stack MSLB Steam cloud, transported over CR intake Reactor Building Stack