RS-05-170, Additional Information Related to Application of Alternative Radiological Source Term - Atmospheric Dispersion Coefficients

From kanterella
(Redirected from RS-05-170)
Jump to navigation Jump to search

Additional Information Related to Application of Alternative Radiological Source Term - Atmospheric Dispersion Coefficients
ML060040081
Person / Time
Site: Byron, Braidwood  
Issue date: 12/09/2005
From: Bauer J
Exelon Generation Co, Exelon Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RS-05-170
Download: ML060040081 (2)


Text

'144MMMW-

Exekn.

Exelon Generation www.exeloncorp.com Nuclear 4300 Winfield Road Warrenville, IL 60555 10 CFR 50.90 RS-05-170 December 9, 2005 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Braidwood Station, Units I and 2 Facility Operating License Nos. NPF-72 and NPF-77 NRC Docket Nos. STN 50-456 and STN 50-457 Byron Station, Units 1 and 2 Facility Operating License Nos. NPF-37 and NPF-66 NRC Docket Nos. STN 50-454 and STN 50-455

Subject:

Additional Information Related to Application of Alternative Radiological Source Term - Atmospheric Dispersion Coefficients

References:

(1) Letter from K. R. Jury (Exelon Generation Company, LLC) to NRC, "Request for License Amendment Related to Application of Alternative Radiological Source Term," dated February 15, 2005 (2)

Letter from J. A. Bauer (Exelon Generation Company, LLC) to NRC, "Additional Information Related to Application of Alternative Radiological Source Term - Dose Calculations," dated December 9, 2005 In Reference 1, Exelon Generation Company, LLC (EGC) requested an amendment to Appendix A Technical Specifications (TS), of Facility Operating License Nos. NPF-72, NPF-77, NPF-37, and NPF-66 for Braidwood Station, Units I and 2, and Byron Station, Units 1 and 2, respectively. The proposed amendment was requested to support application of an alternative source term methodology in accordance with 10 CFR 50.67, "Accident Source Term." During a conference call on December 1, 2005, NRC technical reviewers and EGC personnel discussed aspects of the Reference 1 submittal that required additional information to be provided to allow the NRC to complete its review. EGC agreed to provide the calculations associated with the implementation of the alternative radiological source term to the NRC. Reference 2 provided the associated dose calculations. This submittal transmits the associated onsite and offsite atmospheric dispersion coefficients calculation. The remainder of the NRC requests for additional information discussed during the December 1, 2005, conference call will be addressed in a separate submittal.

The information provided in this submittal does not affect the supporting analysis for the original license amendment request as described in Reference 1. No other information submitted with 4

l

December 9, 2005 U.S. Nuclear Regulatory Commission Page 2 Reference 1 is affected by this additional information. The No Significant Hazards Consideration and the Environmental Consideration provided in Attachment 1 of Reference 1 are not affected by this additional information.

EGC is providing the State of Illinois with a copy of this letter and its attachments to the designated State Official.

If you have any questions about this letter, please contact J. A. Bauer at (630) 657-2801.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 9th day of December 2005.

Respectfully, oseph A. Bauer Manager - Licensing

Attachment:

BYR04-050, BRW-04-0044-M, 'Calculation of Alternative Source Term Onsite and Offsite Atmospheric Dispersion Coefficients," Revision 1, dated November 30, 2004