PNO-II-96-057, on 960814,licensee Reported Tampering on Three Hot Shutdown Panel Key Lock Switches.Tampering Involved Introduction of Foreign Matl Into Key Switches Disabling Use.Replacement of Affected Switches in Progress

From kanterella
(Redirected from PNO-II-96-057)
Jump to navigation Jump to search
PNO-II-96-057:on 960814,licensee Reported Tampering on Three Hot Shutdown Panel Key Lock Switches.Tampering Involved Introduction of Foreign Matl Into Key Switches Disabling Use.Replacement of Affected Switches in Progress
ML17229A002
Person / Time
Site: Saint Lucie  
Issue date: 08/14/1996
From: Landis K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
PNO-II-96-057, PNO-II-96-57, NUDOCS 9608150020
Download: ML17229A002 (2)


( 'A'1'!'(iUJC Y J.

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDE)

ACCESSION NBR:9608150020 DOC.DATE: 96/08/14 NOTARIZED: NO FACIL:50-335 St. Lucie Plant, Unit 1, Florida Power !'ight Co.

50-389 St. Lucie Plant, Unit 2, Florida Power a Light Co.

AUTH.NAME AUTHOR AFFILIATION LANDISFK.

Region 2 (Post 820201)

RECIP.NAME RECIPIENT AFFILIATION DOCKET 05000335 05000389

SUBJECT:

PNO-II-96-057:on 960814,licensee reported tampering on three hot shutdown panel key lock switches. Tampering involved introduction of foreign matl into key switches disabling use.Replacement of affected switches in progress.

DISTRIBUTION CODE:

IE34F COPIES RECEIVED:LTR 8-ENCL

(

SIZE:

TITLE: Preliminary Notification-Occurrence/Non-Routine Event/Safeguards NOTES:

Even C

RECIPIENT ID CODE/NAME INTERNAL: ACRS NRR/DISP/PIPB NUDOCS FULL TXT RES/DET/EIB RES/DRA/DEPY RES/DST DEPY RGN2 FILE 01 EXTERNAL'ITCO BRYCE F J H

NRC PDR COPIES LTTR ENCL RECIPIENT ID CODE/NAME LE C NRR DRPM/PERB OE DIR RES/DRA RES/DST RES/RPHEB NOAC COPIES LTTR ENCL D

U N

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE!

CONTACT THE DOCUMENT CONTROL DESKi ROOM OWFN SD-5(EXT. 415-2083)

TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR ENCL 16

August 14, 1996 PRELIMINARY NOTIFICATION OP EVENT OR UNUSUAL OCCURRENCE PNO-II-96-057 This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance.

The information is as initially received without verification or evaluation, and is basically all that is known by Region II staff in Atlanta, Georgia on this date.

~Pac9.lit Florida Power

& Light Co.

Saint Lucie 1

2 Jensen Beach, Florida Dockets:

50-335,50-389 Licensee Emer enc Classification X Notification of Unusual Event Alert Site Area Emergency General Emergency Not Applicable

Subject:

TAMPERING WITH KEY LOCK SWITCHES On August 14,

1996, the licensee reported tampering on three hot shutdown panel key lock switches (two on unit 2, one on unit 1).

The tampering involved introduction of foreign material (glue) into the key switches disabling their use.

The licensee declared a Notice of Unusual Event (NOUE) due to placing the facility in a state of security alert and has increased security measures.

A corporate security investigator and the FBI are onsite.

An investigation has been initiated.

Corrective actions involve the checking of all other key lock switches and key locked valves.

No other tampering has been identified as a result of the licensee's actions.

The affected switches did not operationally impact the plant.

Both units remain at 100 percent power.

Replacement of affected switches is in progress.

The Resident Inspectors are following the licensee's corrective actions.

Two Regional Security inspectors have been dispatched.

The licensee is issuing a press'elease.

Press interest is anticipated.

The state of Florida and local officials have been notified.

Contact:

K. LANDIS (404)331-5509 9608i50020 9'60814'DR XSE PNO-I E-96-057 PDR