PLA-1613, Monthly Operating Rept for Mar 1983

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for Mar 1983
ML20084M562
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 04/08/1983
From: Kenyon B, Kuczynski L
PENNSYLVANIA POWER & LIGHT CO.
To: Beebe M
NRC OFFICE OF RESOURCE MANAGEMENT (ORM)
References
PLA-1613, NUDOCS 8306020223
Download: ML20084M562 (6)


Text

^

~ '

ANN 4@ AVERAGE DAILY UNIT POWER LEVEL

.D L Cf) ...-

\

3 DOCKET NO. 50-387 L,.

e'u m ki 4

UNIT DATE one 4-8-83 COMPLETED BY L.A. Kuczynski RfC 6 TELEPHONE (717)S42-2181 MONTH March, 1983 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net) (MWe-Net)

I 1025 914 17 2 1024 gg 1023 3 1030 39 748 4 38 20 920 34 1057 5 21 6

546 30 22 7 671 0 23 8 614 24 0 9 1006 25 0 10 493 26 0 28 753 11 27 12 458 28 938 13 20 29 1052 14 64 916 30 .

15 291 33 789 16 708 i INSTRUCTIONS On this format, list the average daily unit power level in MWe Net for each day in the reporting month. Compute to l the nearest whole megawatt.

l (9/77) 830602O223 830408 PDR ADOCK 05000387 R PDR

, . N #4 s)$ j; . . . . ;

E L P' I IIIlM J '

OPERATING DATA REPORT 0 DOCKET NO. 50'-387 O 4s DATE 4-8-83 COMPLETED BY L. A. Kuczynski RIC sY TELEPHONE (717)542-2181 OPERATING STATUS Unit One Notes

1. Unit Name: Susquehanna 5 team Electric Station March, 1983
2. Reporting Period:

3293

3. Licensed Thermal Power (MWt):
4. Nameplate Rating (Gross MWe): 1280 x 0.9 = 1152
5. Design Electrical Rating (Net MWe): 1152 - 41 = 1111
6. Maximum Dependable Capacity (Gross MWe):
7. Maximum Dependable Capacity (Net MWe):
  • MDC to be determined
8. If Changes Occur in Capacity Ratings (Items Number 3 Thmugh 7) Since Last Report. Give Reasons:

None

9. Power Level To Which Restricted,if Any (Net MWe): None
10. Reasons For Restrictions,If Any: None

,t This Month Yr to.Date Cumulative

11. Hours in Reporting Period 744 2160 '3252.5
12. Number Of Hours Reactor Was Critical 584 1613.2 2543.2
13. Reactor Reserve Shutdown Hours 66.7 133 197.6
14. Hours Generator On.Line 522 1460.6 2313.2
15. Unit Reserve Shutdown Hours 0 0 0
16. Gross Thermal Energy Generated (MWH) 1,308,770 3,457,729 4,752,194
17. Gross Electrical Energy Generated (MWH) 431,350 1,150,070 1.494.490
18. Net Electrical Energy Generated (MWH) 411,352 _

1,092,852 1,414,157

19. Unit Service Factor - N/A
20. Unit Availability Factor N/A
21. Unit Capacity Factor (Using MDC Net) N/A
22. Unit Capacity Factor (Using DER Net) N/A
23. Unit Forced Outage Rate N/A
24. Shutdowns Scheduled Over Next 6 Months (Type. Date,and Duration of Each):

None

25. If Shut Down At End Of Report Period. Estimated Date of Startup:
26. Units in Test Status (Prior to Commercial Operation): Forecast Achieved INITIAL CRITICALITY 9-07-82 9-10-82 INITIAL ELECTRICITY 11-19-82 11-16-82 COMMERCIAL OPERATION 5-15-83 (4/77)

@7 , ,

O ff 50-387 L UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.

p UNIT NAME One g

Q DATE 4-8-83 COMPLETED BY Y A- Ku c 7=1< 4 7NIC Si REPORT MOsmi March. 1983 TELEPHONE (717)S42-2181

~

w.

- E E

, .! E };; }Y3 Licensee Eg {"'o Cause & Corrective No. Date o- 3g .c g 5 Event y gU8 Action to H

$% $ j pj g Report # mO g Prevent Recurrence 6 830304 S 41.3 B 3- N/A ZZ ZZZZZZ As part of scheduled startup testing, generator sync breaker was opened to simulate a load rejection. This caused a reactor Scram on turbine control valve fast closure.

7 830310 F 31.8 G 3 N/A Cll INSTRU All feedwater flow transmitters were valved out at one time, causing both recire. pumps to runback. This yielded a scram on high RPV water level. Personnel involved have been counseled.

8 830313 F 32 B 4 N/A IF INSTRU Power' reduction was initiated to facilitate the installation of additional loose parts monitoring sensors.

1 2 3 4 F: Forced Reason: Method: Exhibit G . Instructions S: Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance of Test 2-Manual Scram- Entry Sheets for Licensee C-Refueling 3 Automatic Scram. Event Report (LER) File (NUREG-D-Regulatory Restriction 4-Other (Explain) 0161)

E-Operator Training & License Examination F-Administrative 5 G-Operational Error (Explain) Exhibit I - Same Source (9/77) li-Other (Explain)

4gANN4 ' '

a P hflk 50-387 L L UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.

UNIT NAME One g 4-8-83

$@ N[ DATE L.A. Kuczynski COMPLETED BY

, #fC S REPORT MONT11 March , 1983 TEliPHONE (717)542-2181 e.

- E E No. Date g

.$ E 3g

};; }Y3

,s5 Licensee Event E r, gy {"3

, Cause & Corrective Action to i

y: gU H 5 j ;yj g Report # mV g Prevent Recurrence S

9 830319 S 0 B 4 N/A ZZ ZZZZZZ As part of scheduled startup testing, power reductions were carried out for the performance of a control rod sequence exchange.

10 830322 F 117 G 3 N/A IIG VALVEX Operator error allowed air to be injected into the reactor vessel via the condensate demineralizers.

This yielded a scram on main steam line high radiation. Procedure changes are planned.

I 2 3 4 F: Forced Reason: Method: Exhibit G-Instructions S: Scheduled A Equipment Failure (Explain) l-Manual for Preparation of Data B-Maintenance of Test 2-Manual Scram. Entry Slieets for Licensee C-Refueling 3-Automatic Scram. Event Report (LER) File (NUltEG-D-Regulatory Restriction 4-Other (Explain) 0161)

E-Operator Training & License Examination F-Administrative 5 G-Operational Error (Explain) Exhibit I - Same Source (9/77) II-Other (Explain)

=

r SUSQUEHANNA STEAM ELECTRIC STATION Docket Number 50-387 Date 4-8-83 Completed by L.A. Kuczynski Telephone (717)542-2181 March, 1983 Challenges to Main Steam Safety Relief Valves Af ter the scram of 3-22-83, safety relief valves "C" and "D" were opened manually to provide pressure control. They properly reseated.

Changes to the Offsite Dose Calculation Manual None.

Major Changes to Radioactive Water Treatment Systems None.

L l

l t

l

/

l l

.2 PP&L Pennsylvania Power & Light Company Two North Ninth Street

  • Allentown, PA 18101
  • 215 / 770-5151 Bruce D. Kenyon Vice President-Nuclear Operations 215/770-7502 APR 151983 Director, Data Automation &

Management Information Division Attention: Mr. M. R. Beebe Management Information Branch Office of Resource Management U.S. Nuclear Regulatory Commission Washington, D.C. 20555 SUSQUEHANNA STEAM ELECTRIC STATION MONTHLY OPERATING REPORT - MARCH 1983-ER 100450 FILE 841 PLA-1613 Docket No. 50-387

Dear Mr. Beebe:

The March 1983 monthly operating report for Susquehanna SES Unit 1 is attached.

Very truly yours,

\ h b 6VA_

B. D. Kenyon ,

Vice President-Nuclear Operations Attachment cc: Mr. James M. Allan INPO Records Center Acting Regional Administrator Suite 1500 Region I 1100 Circle 75 Parkway U.S. Nuclear Regulatory Commission Atlanta, Georgia 30339 631 Park Avenue King of Prussia, PA 19406 Director Mr. Thomas E. Pollog Office of Inspection and Enforcement Department of Environmental U.S. Nuclear Regulatory Commission Resources Washington, D.C. 20555 Bureau of Radiation Protection Attn: Document Control Desk (12 copies) P.O. Box 2053 Harrisburg, PA 17120 Mr. G. Rhoads - NRC Mr. R. Perch - NRC 4

-. .. ..