NRC 2004-0053, To Reactor Vessel Closure Head Penetration Repair and Flaw Characterization Relief Requests MR 02-018-1, Revision 1 and MR 02-018-2, Revision 1

From kanterella
(Redirected from NRC 2004-0053)
Jump to navigation Jump to search
To Reactor Vessel Closure Head Penetration Repair and Flaw Characterization Relief Requests MR 02-018-1, Revision 1 and MR 02-018-2, Revision 1
ML050870337
Person / Time
Site: Point Beach  
Issue date: 05/15/2004
From: Vanmiddlesworth G
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
FOIA/PA-2004-0282, MR 02-018-1, Rev 1, MR 02-018-2, Rev 1, NRC 2004-0053
Download: ML050870337 (30)


Text

NMC Committed to Nuclear Excellen Point Beach Nuclear Plant Operated by Nuclear Management Company, LLC May 15, 2004 NRC 2004-0053 10 CFR 50.55a(a)(3)(i) 10 CFR 50.55a(g)(5)(iii)

U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Point Beach Nuclear Plant, Units 1 and 2 Dockets 50-266 License Nos. DPR-24 Supplement 1 to Reactor Vessel Closure Head Penetration Renair and Flaw Characterization Relief Requests MR 02-018-1, Revision 1 and MR 02-018-2, Revision I

Reference:

(1)

Letter from NMC to NRC dated May 13, 2004 (NRC 2004-0051)

(2)

NRC Safety Evaluation dated September 10, 2003 (3)

NRC Safety Evaluation dated September 24, 2003 In reference 1, Nuclear Management Company (NMC) LLC, licensee for Point Beach Nuclear Plant (PBNP), requested revision to the relief, granted in references 2 and 3, pertaining to reactor vessel closure head (RVCH) penetration repair and flaw characterization.

During a conference call between NRC staff and NMC personnel on May 15, 2004, the staff requested additional information in support of their review of Reference 1, regarding crack growth rates in addition to those documented in EPRI MRP-55, "Materials Reliability Program (MRP) Crack Growth Rates for Evaluating Primary Water Stress Corrosion Cracking (PWSCC) of Thick-Wall Alloy 600 Material." Enclosure 1 to this letter provides the additional information requested by the staff.

This submittal provides revised primary water stress corrosion cracking (PWSCC) crack growth correlations and fatigue crack growth calculations, for the repair and flaw characterization, where portions of the new pressure boundary weld overlap onto portions of the remnant J-groove weld. These correlations and calculations address hypothetical growth in Alloy 82 material as a conservative representation for Alloy 52.

The conclusion of the revised calculation shows that, even with the very conservative assumption of using Alloy 82 crack growth rates for Alloy 52 weld material, a hypothetical remnant weld crack will not grow through the repair weld ligament for 1.4 effective full power years (EFPY) of operation. Therefore, the hypothetical flaw could not progress sufficiently to go through the pressure boundary during the next Unit 1 operating cycle.

6590 Nuclear Road

  • Two Rivers, Wisconsin 54241 Vq Telephone: 920.755.2321

Document Control Desk Page 2 This submittal contains no new or revised regulatory commitments.

g~a<W/Va~lMiddlesworth/

Site Vice-President, Point each Nuclear Plant Nuclear Management Company, LLC

Enclosure:

I -

Structural Integrity Associates Calculation PBCH-09Q-302, Revision 2, Dated May 15, 2004 cc:

Project Manager, Point Beach Nuclear Plant, NRR, USNRC Regional Administrator, Region l1l, USNRC NRC Resident Inspector - Point Beach Nuclear Plant PSCW

ENCLOSURE I STRUCTURAL INTEGRITY ASSOCIATES CALCULATION PBCH-09Q-302, REVISION 2, DATED MAY 15, 2004 PWSCC CRACK GROWTH CORRELATIONS AND FATIGUE CRACK GROWTH CALCULATIONS FOR POINT BEACH UNIT I POINT BEACH NUCLEAR PLANT, UNIT I

l 9j FILE No.: PBCH-09Q-3@2 l

l STRUCTURAL CALCULATION l

INTEGRITY PACKAGE PROJECT No.: PBCH-09Q Associates, Inc.

l PROJECT NAME: Point Beach Unit I CRDM Top Head Analysis CLIENT: NMC Point Beach Nuclear Plant l

CALCULATION TITLE: PWSCC Crack Growth Correlations and Fatigue Crack Growth Calculations for Point Beach Unit I Project Mgr.

Preparer(s) &

Document Affected Approval Checker(s)

Revision Pages Revision Description Signature &

Signatures &

Date Date 0

1-7 Original Issue H. L. GUSTIN H. L. GUSTIN Al -A19 2/17/04 2/17/04 G. L. STEVENS 2/17/04 1

1-7 Incorporates actual overlap H. L. GUSTIN H. L. GUSTIN measurements for nozzle 26.

AI-A19 Appendix A is not affected.

i t

etA 5/12/04 5/12/04 MING QIN 5/12/04 2

1-8 Addresses hypothetical growth in Alloy H. L. GUSTIN H. L. GUSTIN 82 material, as a conservative Al-A19 representation for Alloy 52 5/15/04 RICCARDELLA 5/15/04 Page I of 8

--~n -. 11

1.0 STATEMENT OF PROBLEM Point Beach Unit I is proceeding with repair of RPV top head CRDM Nozzle 26 during the current, Spring 2004 refueling outage. Because of the steepness of this nozzle, and the relatively small head diameter and thickness, the standard Framatome repair process will result in a portion of the new attachment weld overlapping the original Alloy-82/182 weld over a portion of the circumference (see Figure 1).

In order to evaluate repair options for the Point Beach Unit I Top Head CRDM penetrations, this calculation evaluates the growth of hypothetical flaws in the original alloy 82/182 weld through the weld repair fusion line with the low alloy steel base material. Earlier revisions of this calculation assumed a crack growth rate applicable to Alloy-600 base metal. To respond to NRC comments received on the earlier calculation, the calculation is revised herein to incorporate crack growth rates applicable to Alloy 82 weld metal.

Note that the repair weld through which the hypothetical crack is assumed to be propagating is Alloy-52, which has generally been shown to be highly resistant to PWSCC cracking and crack growth. The only potential crack growth region is at the fusion line between the low alloy steel nozzle and the Alloy-52 weld metal, in which some dilution of the weld metal may occur. Both the Alloy-600 and Alloy-82 crack growth curves are believed to be conservative approximations of the expected crack growth rate in this dilution zone.

2.0 METHODOLOGY Stress intensity factors at the interface of the new, Alloy-52 repair weld and the original, Alloy-82/182 J-groove weld have been computed in Ref [5] assuming the entire original J-groove weld to be cracked. These K-levels are based on operating plus residual stresses resulting from the original J-groove weld plus the new repair weld, at normal operating conditions. The result K-levels are assumed to remain constant for the small amount of crack extension through the interface region, since the cracking will be confined to a narrow region of diluted material.

The resulting K-levels are then inserted into a stress corrosion crack growth law (see section 3.0 below) to determine the rate of crack propagation versus time, and to predict the time necessary for the assumed initial crack to grow through the new repair weld diluted zone and thus cause potential leakage during the upcoming fuel cycle.

File No.

PBCH-09Q-302 I

3.0 MATERIAL CRACK GROWTH RATE The industry has established a panel of experts on stress corrosion cracking to review available data on PWSCC growth in components such as the CRDM penetration tubes and associated nickel-based weld metals. The panel is comprised of international experts, including representatives from NRC research and its contractors. This panel has established a recommended crack growth law for Alloy-600 base material [1], and more recently a recommended crack growth curves for Alloy 82 and 182 weld metals [2]. The correlation of available crack growth data from

[2] is shown in Figure 2, normalized to a service temperature of 617 'F. The reported top head temperature for Point Beach Unit I is 5920F [7]. The crack growth rate is a strong function of temperature, and so to represent the Point Beach condition, it is necessary to adjust the Alloy-82 crack growth correlation for the lower temperature. References I and 2 also provide an activation energy equation for temperature adjustment of the crack growth curves.

For Alloy-82 weld material the PWSCC crack growth correlation reported in [2], adjusted to the Point Beach head temperature of 5920F is da/dt = 5.12 x 10.08 (K-Kh) 6 where:

da/dt = crack growth rate at temperature T in in/hr K

= crack tip stress intensity factor (ksilin)

Kth

= crack tip stress intensity factor threshold

= 0 (ksiq/in)

This correlation is applicable to evaluating the growth of ID connected flaws in Alloy 82 GTAWV weld material. Since the diluted zone being evaluated in this calculation is Alloy-52, also a GTAW welding process, the Alloy-82 curve is conservatively applied.

As noted above, the repair material is Alloy 52. Since chromium content has been shown to be a key contributor to nickel-based alloy PWSCC resistance, this material (Alloy 52, with a chromium content of 28-31%) will have significantly higher PWSCC resistance than will Alloy 600 (chromium content 14-17%) or its associated weld materials Alloy 182 (chromium content 13-17%) or Alloy 82 (chromium content 18-22 %). The lower chromium content of the Alloy -82 material is deemed sufficient to account for the potential effects of dilution of the Alloy-52 material in the interface region with the low alloy steel head.

Revision 0

1 2

Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page 3 of 8

4.0 CRACK GROWTH CALCULATIONS The objective of the calculation is to determine the time that would be required for a crack at the interface of the Alloy 52 repair material, the low alloy steel head material, and the underlying J-groove material to propagate parallel to the repair weld by a PWSCC mechanism through a distance defined by the repair weld ligament. If the time for such propagation is greater than the remaining service life of the head, no penetration of the pressure boundary due to such a crack would be predicted.

The above crack growth correlation was used with the SI program pc-CRACK [3] to perform PWSCC crack growth calculations. A hypothetical flaw was considered, which represents the bounds on geometries that may be encountered. This hypothetical flaw was a flaw in the axial-radial plane, across the entire remaining J-groove + butter. Such a flaw would be opened by hoop stresses, resulting in a tunnel crack under the repair weld.

PWSCC is driven by both applied and weld residual'stresses. -Based on analyses performed by Dominion Engineering [3], as summarized in another SI calculation [5], the normal operating stresses plus the weld residual stresses in the hoop direction can reasonably be represented by a constant through-wall stress intensity factor of 57 ksiVin, at the junction of the Alloy-52 repair weld and the low alloy steel head material.

The analysis assumed that the entire original J-groove weld material was degraded (cracked), so no credit was taken for any flaw initiation or growth time in the remaining J-groove material. Because a constant applied K is assumed, starting flaw size has no effect on crack growth rate.

The flaw located in the axial-radial plane (opened by hoop stresses) was determined to be the governing flaw case, since the applied plus residual stresses in the hoop direction are greater than those in the radial direction by a factor of two to four at the location of the postulated crack, based upon review of Dominion Engineering results [3] for nodes in this location. As a result, crack growth in a radial-circumferential plane would be slower by a comparable factor.

Nozzle 26 is being repaired during the Spring 2004 outage. The repair of this nozzle has a minimum remaining ligament of 0.5 inch [6]. The repair may also contain a weld root defect of 0.1 inch based on Framatome analyses. Both cases (with and without a postulated root defect) are considered here, with pc-CRACK results contained in Appendix A.

This analysis took no credit for the portion of the repair weld that overlapped the Alloy 182 material, and so as a result the repair weld ligament was considered to be reduced in length from the design value. The repair weld is Alloy 52 weld material applied by a GTAW process.

Revision 0

1 2

Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page 4 of 8

4.1 Fatigue crack growth Fatigue crack growth is driven by cyclic stresses. For the present case, the stress state for the assumed flaws is dominated by weld residual stresses (conservatively estimated as a constant 60 ksi) which are steady state secondary stresses. These residual stresses will not vary with heat-lup/cooldown and other plant cycles, and will therefore have only a limited effect on fatigue crack growth (that is, they will have some effect on R-ratio, but none on delta K values due to cyclic plant operation. For the limited period of remaining plant operation with the current vessel head (estimated at less than 100 heat-up/cooldown cycles, producing a cyclic stress of 20 ksi),

propagation of the hypothetical cracks considered herein by a fatigue mechanism is estimated at approximately 0.0002 inch, and is therefore considered negligible compared to PWSCC propagation discussed above. The pc-CRACK fatigue crack growth results are also included in Appendix A.

5.0 RESULTS The above analysis produces the following results. These results assume that an initial radial-axial flaw is present in the original J-groove weld, equal to the entire size of that weld. The growth is then calculated for the indicated remaining ligament length of potentially diluted Alloy-52 weld metal in the repair weld..

For the nozzle 26 repair (remaining ligament = 0.5 inch without an assumed root defect, or 0.4 inch with an assumed root defect), the time required for the assumed flaw to propagate through the remaining ligament is 1.73 EFPY (15200 EFPH) for the no root defect case, and 1.39 EFPY (12200 EFPH) for the root defect case. A crack would have to propagate through this remaining ligament before leakage and possible wastage of the vessel head material could occur.

The conclusion of this calculation is that, even with the very conservative assumption of using Alloy 82 crack growth rates for Alloy 52 weld material, a hypothetical remnant weld crack will not grow through the repair weld ligament for essentially all of the remaining cycle of operation before the reactor vessel head is replaced during the next scheduled refueling outage.

Revision 0

1 2

V Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page 5 of 8

6.0 REFERENCES

1. Materials Reliability Program, "Crack Growth Rates for Evaluating Primary Water Stress Corrosion Cracking (PWSCC) of Thick-Wall Alloy 600 Material," MRP-55, Revision 1, November 2002. EPRI Proprietary
2. Minutes of EPRI-MRP PWSCC Crack Growth Expert Panel Meeting, October 3, 2003 -

Gaithersburg, Maryland, EPRI Letter PWR-MRP 2003-38 by John Hickling, October 20, 2003.

MRP Proprietary.

3. Dominion Engineering, "Point Beach Unit I CRDM Nozzle Repair Weld Analysis" Calculation C-4430-00-2, Revision 1, SI File PBCH-09Q-204.
4. Structural Integrity Associates, pc-CRACK"m for Windows, version 3.1-98348.
5. Calculation, "Fracture Mechanics Evaluation of Point Beach Unit I Top Head CRDM 43.5 Degree Azimuth Penetration Weld Repair," PBCH-09Q-301, Revision 0.
6. E-mail from Brian Kemp (NMC) to Hal Gustin (SI) 5/12/04
7. Materials Reliability Program, "Interim Alloy 600 Safety Assessments for US PWR Plants, Part 2: Reactor Vessel Top Head penetrations," MRP-44, EPRI Report No. TP-1001491, Part 2, May 2001 Revision 0

1 2

Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page 6 of 8

Figure I - Illustration of Nozzle 26 Repair and Associated Overlap Region

.a>32 Revision 0

1 2

Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page 7 of 8

Figure 2-Alloy-82 and -182 Crack Growth Rate Correlations at 617 'F, from Reference [2]

1.0OE-03 1.OOE-04

' 1.00E-05 C,

1.00E-06 1.00E-07 0

10 20 30 40 50 60 70 80 K (ksl-InA.5)

Revision 0

1 2

Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page 8 of 8

APPENDIX A FLAW GROWTH CALCULATIONS: PC-CRACK OUTPUT Revision 0

1 2

VPreparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page Al of A19

tm pc-CRACK for Windows Version 3.1-98348 (C) Copyright '84 - '98 Structural Integrity Associates, Inc.

3315 Almaden Expressway, Suite 24 San Jose, CA 95118-1557 Voice: 408-978-8200 Fax:

408-978-8964 E-mail: pccrackgstructint.com Linear Elastic Fracture Mechanics Date: Thu May 13 15:05:22 2004 Input Data and Results File: ALLOY82.LFM

Title:

PBCH-09Q: PWSCC Calculation using Alloy 82 Load Cases:

Case ID: PWSCC --- K vs a Depth K

0.0000 57.0000 0.5000 57.0000 2.0000 57.0000 Stress Coefficients Case ID Co Cl C2 C3 Type PWSCC 0

0 0

0 Kvsa Crack Model: User Input K Versus Crack Size Crack Parameters:

Max. crack size:

1.0000


Stress Intensity Factor--------------------

Crack Case Size PWSCC 0.0200 57 0.0400 57 0.0600 57 0.0800 57 0.1000 57 0.1200 57 0.1400 57 0.1600 57 0.1800 57 0.2000 57 0.2200 57 0.2400 57 0.2600 57 0.2800 57 0.3000 57 0.3200 57 0.3400 57 0.3600 57 0.3800 57 0.4000 57 0.4200 57 0.4400 57 0.4600 57 0.4800 57 0.5000 57 0.5200 57 0.5400 57 0.5600 57 0.5800 57 0.6000 57 0.6200 57 0.6400 57 0.6600 57 0.6800 57

0.7000 57 0.7200 57 0.7400 57 0.7600 57 0.7800 57 0.8000 57 0.8200 57 0.8400 57 0.8600 57 0.8800 57 0.9000 57 0.9200 57 0.9400 57 0.9600 57 0.9800 57 1.0000 57 Crack Growth Laws:

Law ID: Alloy 82 Type: Corrosion Model: Paris da/dN = c * (dK)An where dK = Kmax - Kmin dK > Kthres Kmax<Klc Material parameters:

c= 5.1200e-008 n=

1.6000 Kthres=

0.0000 Material Fracture Toughness KIc:

Material ID: Alloy 52 Depth KIc I

I

0.0000 200.0000 0.5000 200.0000 2.0000 200.0000 Initial crack size=

0.0100 Max. crack size=

1.0000 Number of blocks=

I Print increment of block=

I Cycles Calc. Print Crk. Grw.

Subblock

/Time incre. incre. Law Mat.

Klc PWSCC 40000 100 100 Alloy 82 Alloy 52 Kmax Kmin Subblock Case ID Scale Factor Case ID Scale Factor PWSCC PWSCC 1.0000 Crack growth results:

Total Subblock Cycles Cycles DaDn Kmax Kmin DeltaK R

/DaDt

/Time /Time Da a a/thk Block:

I 100 100 4.03e+001 0.OOe+000 4.03e+001 0.00 1.90e-005 1.90e-003 0.0119 0.00 200 200 4.40e+001 0.OOe+000 4.40e+001 0.00 2.18e-005 2.18e-003 0.01407 -

247674372620288.00 300 300 4.78e+001 0.OOe+000 4.78e+001 0.00 2.49e-005 2.49e-003 0.01657 593.04 400 400 5.19e+001 0.OOe+000 5.19e+001 0.00 2.84e-005 2.84e-003 0.01941 -0.00 500 500 5.61e+001 0.OOe+000 5.61e+001 0.00 3.22e-005 3.22e-003 0.02263 -0.00 600 600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.02593 0.00 700 700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.02923 0.00 File No.

PBCH-09Q-302 Page A5 of A19 I

800 900 1000 1100 1200 1300 1400

,1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 3600 3700 3800 3900 4000 4100 4200 4300 4400 4500 4600 4700 4800 800 5.70e+001 900 5.70e+001 1000 5.70e+001 1100 5.70e+001 1200 5.70e+001 1300 5.70e+001 1400 5.70e+001 1500 5.70e+001 1600 5.70e+001 1700 5.70e+001 1800 5.70e+001 1900 5.70e+001 2000 5.70e+001 2100 5.70e+001 2200 5.70e+001 2300 5.70e+001 2400 5.70e+001 2500 5.70e+001 2600 5.70e+001 2700 5.70e+001 2800 5.70e+001 2900 5.70e+001 3000 5.70e+001 3100 5.70e+001 3200 5.70e+001 3300 5.70e+001 3400 5.70e+001 3500 5.70e+001 3600 5.70e+001 3700 5.70e+001 3800 5.70e+001 3900 5.70e+001 4000 5.70e+001 4100 5.70e+001 4200 5.70e+001 4300 5.70e+001 4400 5.70e+001 4500 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.0Oe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.03253 0.00 0.00 3.30e-005 3.30e-003 0.03583 0.00 0.00 3.30e-005 3.30e-003 0.03913 0.00 0.00 3.30e-005 3.30e-003 0.04244 0.00 0.00 3.30e-005 3.30e-003 0.04574 0.00 0.00 3.30e-005 3.30e-003 0.04904 0.00 0.00 3.30e-005 3.30e-003 0.05234'0.00 0.00 3.30e-005 3.30e-003 0.05564 0.00 0.00 3.30e-005 3.30e-003 0.05894 0.00 0.00 3.30e-005 3.30e-003 0.06224 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.06554 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.06885 0.00 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+00 1 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOc+000 5.70c+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.00e+000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.07215 0.00 0.00 3.30e-005 3.30e-003 0.07545 0.00 0.00 3.30e-005 3.30e-003 0.07875 0.00 0.00 3.30e-005 3.30e-003 0.08205 0.00 0.00 3.30e-005 3.30e-003 0.08535 0.00 0.00 3.30e-005 3.30e-003 0.08865 0.00 0.00 3.30e-005 3.30e-003 0.09195 0.00 0.00 3.30e-005 3.30e-003 0.09525 0.00 0.00 3.30e-005 3.30e-003 0.09856 0.00 0.00 3.30e-005 3.30e-003 0.1019 0.00 0.00 3.30e-005 3.30e-003 0.1052 0.00 0.00 3.30e-005 3.30e-003 0.1085 0.00 0.00 3.30e-005 3.30e-003 0.1118 0.00 0.00 3.30e-005 3.30e-003 0.1151 0.00 0.00 3.30e-005 3.30e-003 0.1184 0.00 0.00 3.30e-005 3.30e-003 0.1217 0.00 0.00 3.30e-005 3.30e-003 0.125 0.00 0.00 3.30e-005 3.30e-003 0.1283 0.00 0.00 3.30e-005 3.30e-003 0.1316 0.00 0.00 3.30e-005 3.30e-003 0.1349 0.00 0.00 3.30e-005 3.30e-003 0.1382 0.00 0.00 3.30e-005 3.30e-003 0.1415 0.00 0.00 3.30e-005 3.30e-003 0.1448 0.00 0.00 3.30e-005 3.30e-003 0.1481 0.00 0.00 3.30e-005 3.30e-003 0.1514 0.00 0.00 3.30e-005 3.30e-003 0.1547 0.00 4600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.158 0.00 4700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.1613 0.00 4800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.1646 0.00 Revision 0

1 2

Preparer/Date HLG 2/17/04 HLG 5/12104 HLG 5/15/04 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page A6 of A19

4900 5000 5100 5200 5300 5400 I

5500 5600 5700 5800 5900 6000 6100 6200 6300 6400 6500 4900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.1679 0.00 5000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.1712 0.00 5100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.1745 0.00 5200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.1778 0.00 5300 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.1811 0.00 5400 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.1844 0.00 5500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.1877 0.00 5600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.191 0.00 5700 5.70e+001 5800 5.70e+001 5900 5.70e+001 6000 5.70e+001 6100 5.70e+001 6200 5.70e+001 0.OOe+000 5.70e+00l 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001

.0OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.1943 0.00 0.00 3.30e-005 3.30e-003 0.1976 0.00 0.00 3.30e-005 3.30e-003 0.2009 0.00 0.00 3.30e-005 3.30e-003 0.2042 0.00 0.00 3.30e-005 3.30e-003 0.2075 0.00 0.00 3.30e-005 3.30e-003 0.2108 0.00 0.00 3.30e-005 3.30e-003 0.2141 0.00 0.00 3.30e-005 3.30e-003 0.2174 0.00 0.00 3.30e-005 3.30e-003 0.2207 0.00 6300 5.70e+001 0.OOe+000 5.70e+001 6400 5.70e+001 0.OOe+000 5.70e+001 6500 5.70e+001 0.OOe+000 5.70e+001 6600 6600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.224 0.00 6700 6800 6900 7000 7100 7200 7300 7400 7500 7600 7700 7800 7900 8000 8100 8200 8300 8400 8500 8600 8700 8800 8900 6700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2273 0.00

,6800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2306 0.00 6900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2339 0.00 7000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2372 0.00 7100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2405 0.00 7200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2438 0.00 7300 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2471 0.00 7400 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2504 0.00 7500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2537 0.00 7600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.257 0.00 7700 5.70e+001 7800 5.70e+001 7900 5.70e+001 8000 5.70e+001 8100 5.70e+001 8200 5.70e+001 8300 5.70e+001 8400 5.70e+001 8500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2603 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2636 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2669 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2702 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2735 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2768 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2801 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2834 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2867 0.00 8600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.29 0.00 8700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2933 0.00 8800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2966 0.00 8900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.2999 0.00 Revision 0

1 2

V Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page A7 of A19

9000 9100 9200 9300 9400 9500 9600 9700 9800 9900 10000 10100 10200 10300 10400 10500 10600 10700 10800 10900 11000 11100 11200 11300 11400 11500 11600 11700 11800 11900 12000 12100 12200 12300 12400 12500 12600 12700 12800 12900 13000 9000 5.70e+001 0.OOe+000 5.70e+001 9100 5.70e+001 9200 5.70e+001 9300 5.70e+001 9400 5.70e+001 9500 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3032 0.00 0.00 3.30e-005 3.30e-003 0.3065 0.00 0.00 3.30e-005 3.30e-003 0.3098 0.00 0.00 3.30e-005 3.30e-003 0.3131 0.00 0.00 3.30e-005 3.30e-003 0.3164 0.00 0.00 3.30e-005 3.30e-003 0.3197 0.00 0.00 3.30e-005 3.30e-003 0.323 0.00 9600 5.70e+001 0.OOe+000 5.70e+001 9700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3263 0.00 9800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3296 0.00 9900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3329 0.00 10000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3362 0.00 10100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3395 0.00 10200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3428 0.00 10300 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3461 0.00 10400 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3494 0.00 10500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3527 0.00 10600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.356 0.00 10700 5.70e+001 10800 5.70e+001 10900 5.70e+001 11000 5.70e+001 11100 5.70e+001 11200 5.70e+001 11300 5.70e+001 11400 5.70e+001 11500 5.70e+001 11600 5.70e+001 11700 5.70e+001 11800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3593 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3627 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.366 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3693 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3726 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3759 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3792 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3825 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3858 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3891 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3924 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.3957 0.00 11900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.399 0.00 12000 5.70e+001 12100 5.70e+001 12200 5.70e+001 12300 5.70e+001 12400 5.70e+001 12500 5.70e+001 12600 5.70e+001 12700 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4023 0.00 0.00 3.30e-005 3.30e-003 0.4056 0.00 0.00 3.30e-005 3.30e-003 0.4089 0.00 0.00 3.30e-005 3.30e-003 0.4122 0.00 0.00 3.30e-005 3.30e-003 0.4155 0.00 0.00 3.30e-005 3.30e-003 0.4188 0.00 0.00 3.30e-005 3.30e-003 0.4221 0.00 0.00 3.30e-005 3.30e-003 0.4254 0.00 0.00 3.30e-005 3.30e-003 0.4287 0.00 0.00 3.30e-005 3.30e-003 0.432 0.00 12800 5.70e+001 0.OOe+000 5.70e+001 12900 5.70e+001 0.OOe+000 5.70e+001 13000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4353 0.00 Revision 0

1 2

V Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page A8 of A19

13100 13200 13300 13400 13500 13600 13700 13800 13900 14000 14100 14200 14300 14400 14500 14600 14700 14800 14900 15000 15100 15200 15300 15400 15500 15600 15700 13100 5.70e+001 0.OOe+000 5.70e+001 13200 5.70e+001 0.00e+000 5.70e+001 13300 5.70e+001 0.OOe+000 5.70e+001 13400 5.70e+001 0.OOe+000 5.70e+001 13500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4386 0.00 0.00 3.30e-005 3.30e-003 0.4419 0.00 0.00 3.30e-005 3.30e-003 0.4452 0.00 0.00 3.30e-005 3.30e-003 0.4485 0.00 0.00 3.30e-005 3.30e-003 0.4518 0.00 13600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4551 13700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4584 13800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4617 13900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.465 0.00 0.00 0.00 0.00 14000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4683 0.00 14100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4716 0.00 14200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4749 0.00 14300 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4782 0.00 14400 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4815 0.00 14500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4848 0.00 14600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4881 0.00 14700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4914 0.00 14800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.4947 0.00 14900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003.0.498 0.00 15000 5.70e+001 0.OOe+000 5.70e+001 15100 5.70e+001 0.OOe+000 5.70e+001 15200 5.70e+001 0.OOe+000 5.70e+001 15300 5.70e+001 0.OOe+000 5.70e+001 15400 5.70e+001 0.OOe+000 5.70e+001 15500 5.70e+001 0.OOe+000 5.70e+001 15600 5.70e+001 0.OOe+000 5.70e+001 15700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.5013 0.00 0.00 3.30e-005 3.30e-003 0.5046 0.00 0.00 3.30e-005 3.30e-003 0.5079 0.00 0.00 3.30e-005 3.30e-003 0.5112 0.00 0.00 3.30e-005 3.30e-003 0.5145 0.00 0.00 3.30e-005 3.30e-003 0.5178 0.00 0.00 3.30e-005 3.30e-003 0.5211 0.00 0.00 3.30e-005 3.30e-003 0.5244 0.00 15800 15800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.5277 0.00 15900 15900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.531 0.00 16000 16100 16200 16300 16400 16500 16600 16700 16800 16900 17000 17100 16000 5.70e+001 16100 5.70c+001 16200 5.70e+001 16300 5.70e+001 16400 5.70e+001 16500 5.70e+001 16600 5.70e+001 16700 5.70e+001 16800 5.70e+001 16900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.5343 0.00 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.5376 0.00 0.00 3.30e-005 3.30e-003 0.5409 0.00 0.00 3.30e-005 3.30e-003 0.5442 0.00 0.00 3.30e-005 3.30e-003 0.5475 0.00 0.00 3.30e-005 3.30e-003 0.5508 0.00 0.00 3.30e-005 3.30e-003 0.5541 0.00 0.00 3.30e-005 3.30e-003 0.5574 0.00 0.00 3.30e-005 3.30e-003 0.5607 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.564 0.00 17000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.5673 0.00 17100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.5706 0.00 Revision 0

1 2

Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 Checker/Date GLS 2117/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page A9 of A19

17200 17300 17400 17500 17600 17700 17800 17900 18000 18100 18200 18300 18400 18500 18600 18700 18800 18900 19000 19100 19200 19300 19400 19500 19600 19700 19800 19900 20000 20100 20200 20300 20400 20500 20600 20700 20800 20900 21000 17200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.5739 0.00 17300 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.5772 0.00 17400 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.5805 0.00 17500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.5838 0.00 17600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.5871 0.00 17700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.5904 0.00 17800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.5937 0.00 17900 5.70e+001 0.00e+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.597 0.00 18000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6003 0.00 18100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6036 0.00 18200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6069 0.00 18300 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6102 0.00 18400 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6135 0.00 18500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6168 0.00 18600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6201 0.00 18700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6234 0.00 18800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6267 0.00 18900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.63 0.00 19000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6333 0.00 19100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6366 0.00 19200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.64 0.00 19300 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6433 0.00 19400 5.70e+001 19500 5.70e+001 19600 5.70e+001 19700 5.70e+001 19800 5.70e+001 19900 5.70e+001 20000 5.70e+001 20100 5.70e+001 20200 5.70e+001 20300 5.70e+001 20400 5.70e+001 20500 5.70e+001 20600 5.70e+001 20700 5.70e+001 20800 5.70e+001 20900 5.70e+001 21000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6466 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6499 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6532 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6565 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6598 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6631 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6664 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6697 0.00 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.673 0.00 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.6763 0.00 0.00 3.30e-005 3.30e-003 0.6796 0.00 0.00 3.30e-005 3.30e-003 0.6829 0.00 0.00 3.30e-005 3.30e-003 0.6862 0.00 0.00 3.30e-005 3.30e-003 0.6895 0.00 0.00 3.30e-005 3.30e-003 0.6928 0.00 0.00 3.30e-005 3.30e-003 0.6961 0.00 0.00 3.30e-005 3.30e-003 0.6994 0.00 21100 21100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7027 0.00 21200 21200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.706 0.00 Revision 0

1 2

Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page AIO of A19

21300 21400 21500 21600 21700 21800 21900 22000 22100 22200 22300 22400 22500 22600 22700

22800, 22900 23000 23100 23200 23300 23400 23500 23600 23700 23800 23900 24000 24100 24200 24300 24400 24500 24600 24700 24800 24900 25000 25100 25200 21300 5.70e+001 0.OOe+000 5.70e+001 21400 5.70e+001 0.OOe+000 5.70e+001 21500 5.70e+001 0.OOe+000 5.70e+001 21600 5.70e+001 0.OOe+000 5.70e+001 21700 5.70e+001 0.OOe+000 5.70e+001 21800 5.70e+001 0.OOe+000 5.70e+001 21900 5.70e+001 0.OOe+000 5.70e+001 22000 5.70e+001 0.OOe+000 5.70e+001 22100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7093 0.00 0.00 3.30e-005 3.30e-003 0.7126 0.00 0.00 3.30e-005 3.30e-003 0.7159 0.00 0.00 3.30e-005 3.30e-003 0.7192 0.00 0.00 3.30e-005 3.30e-003 0.7225 0.00 0.00 3.30e-005 3.30e-003 0.7258 0.00 0.00 3.30e-005 3.30e-003 0.7291 0.00 0.00 3.30e-005 3.30e-003 0.7324 0.00 0.00 3.30e-005 3.30e-003 0.7357 0.00 22200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.739 0.00 22300 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7423 0.00 22400 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7456 0.00 22500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7489 0.00 22600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7522 0.00 22700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7555 0.00 22800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7588 0.00 22900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7621 0.00 23000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7654 0.00 23100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7687 0.00 23200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.772 0.00 23300 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7753 0.00 23400 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7786 0.00 23500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7819 0.00 23600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7852 0.00 23700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7885 0.00 23800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7918 0.00 23900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7951 0.00 24000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.7984 0.00 24100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8017 0.00 24200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.805 0.00 24300 5.70e+001 24400 5.70e+001 24500 5.70e+001 24600 5.70e+001 24700 5.70e+001 24800 5.70e+001 24900 5.70e+001 25000 5.70e+001 25100 5.70e+001 25200 5.70e+001 0.Oe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.OOe+000 5.70e+001 0.0Oe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8083 0.00 0.00 3.30e-005 3.30e-003 0.8116 0.00 0.00 3.30e-005 3.30e-003 0.8149 0.00 0.00 3.30e-005 3.30e-003 0.8182 0.00 0.00 3.30e-005 3.30e-003 0.8215 0.00 0.00 3.30e-005 3.30e-003 0.8248 0.00 0.00 3.30e-005 3.30e-003 0.8281 0.00 0.00 3.30e-005 3.30e-003 0.8314 0.00 0.00 3.30e-005 3.30e-003 0.8347 0.00 0.00 3.30e-005 3.30e-003 0.838 0.00 25300 25300 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8413 0.00 Revision 0

1 2

Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 GChecker/Date LS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page All of A19

25400 25400 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8446 0.00 25500 25500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8479 0.00 25600 25600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8512 0.00 25700 25700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e.003 0.8545 0.00 25800 25800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8578 0.00 25900 25900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8611 0.00 26000 26000 5.70e+001 0.00e+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8644 0.00 26100 26100 5.70e+001 0.00e+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8677 0.00 26200 26200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.871 0.00 26300 26300 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8743 0.00 26400 26400 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8776 0.00 26500 26500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8809 0.00 26600 26600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8842 0.00 26700 26700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8875 0.00 26800 26800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8908 0.00 26900 26900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8941 0.00 27000 27000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.8974 0.00 27100 '27100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9007 0.00 27200 27200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.904 0.00 27300 27300 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9073 0.00 27400 27400 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9106 0.00 27500 27500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.914 0.00 27600 27600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9173 0.00 27700 27700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9206 0.00 27800 27800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9239 0.00 27900 27900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9272 0.00 28000 28000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9305 0.00 28100 28100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9338 0.00 28200 28200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9371 0.00 28300 28300 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9404 0.00 28400 28400 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9437 0.00 28500 28500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.947 0.00 28600 28600 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9503 0.00 28700 28700 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9536 0.00 28800 28800 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9569 0.00 28900 28900 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9602 0.00 29000 29000 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9635 0.00 29100 29100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9668 0.00 29200 29200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9701 0.00 29300 29300 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9734 0.00 29400 29400 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9767 0.00 Revision 0

1 2

Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page A12 of A19

29500 29500 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.98 0.00 29600 29600 5.70e+001 0.00e+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9833 0.00 29700 29700 5.70e+001 0.00e+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9866 0.00 29800 29800 5.70e+001 0.00e+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9899 0.00 29900 29900 5.70e+001 O.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9932 0.00 30000 30000 5.70e+00I 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9965 0.00 30100 30100 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 0.9998 0.00 30200 30200 5.70e+001 0.OOe+000 5.70e+001 0.00 3.30e-005 3.30e-003 1.003 0.00 Crack size exceeded 1.0000 at cycle/time 30200 End of pc-CRACK Output I

tm pc-CRACK for Windows Version 3.1-98348 (C) Copyright '84 - '98 Structural Integrity Associates, Inc.

3315 Almaden Expressway, Suite 24 San Jose, CA 95118-1557 Linear Elastic Fracture Mechanics ate: Mon Feb 09 10:59:19 2004 nput Data and Results File: PB I FCG.LFM tie: PBCH-09Q-302: Point Beach Unit I Fatigue Crack Growth oad Cases:

Stress Coefficients ase ID Co Cl C2 C3 Type Residual 60 0

0 0 Coeff perating 20 0

0 0 Coeff


Through Wall Stresses for Load Cases With Stress Coeff-----

Wall Case Case Depth Residual Operating 0.0000 60 20 0.1000 60 20 0.2000 60 20 0.3000 60 20 0.4000 60 20 0.5000 60 20 0.6000 60 20 0.7000 60 20 0.8000 60 20 0.9000 60 20 1.0000 60 20

-rack Model: Single Edge Cracked Plate rack Parameters:

I

Plate width:

2.0000 ax. crack size:

1.0000

.Stress Intensity Factor-------------------

Crack Case Case Size Residual Operating 0.0200 16.2806 5.42685 0.0400 23.1837 7.7279 0.0600 28.5895 9.52983 0.0800 33.2379 11.0793 0.1000 37.4133 12.4711 0.1200 41.2605 13.7535 0.1400 44.8649 14.955 0.1600 48.2816 16.0939 0.1800 51.5488 17.1829 0.2000 54.6939 18.2313 0.2200

.58.4858 19.4953 0.2400 62.2586 20.7529 0.2600 66.021 22.007 0.2800 69.7794 23.2598 0.3000 73.5391 24.513 0.3200 77.3044 25.7681 0.3400 81.0788 27.0263 0.3600 84.8651 28.2884 0.3800 88.6656 29.5552 0.4000 92.4824 30.8275 0.4200 97.0061 32.3354 0.4400 101.582 33.8605 0.4600 106.209 35.4029 0.4800 110.888 36.9626 0.5000 115.618 38.5394 0.5200 120.4 40.1334 0.5400 125.234 41.7446 0.5600 130.118 43.3727 0.5800 135.054 45.0179 0.6000 140.04 46.6799 0.6200 146.332 48.7773 0.6400 152.715 50.9049 0.6600 159.186 53.0621 0.6800 165.746 55.2486 0.7000 172.392 57.464 0.7200 179.124 59.7079 0.7400 185.94 61.98 0.7600 192.84 64.2799 0.7800 199.822 66.6073 0.8000 206.886 68.9619 Revision 0

1 2

Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No..

PBCH-09Q-302 Page A15 of A19

0.8200 216.919 72.3064 0.8400 227.102 75.7008 0.8600 237.433 79.1444 0.8800 247.91 82.6366 0.9000 258.53 86.1767 0.9200 269.292 89.7641 0.9400 280.195 93.3982 0.9600 291.235 97.0783 0.9800 302.412 100.804 1.0000 313.724 104.575 rack Growth Laws:

Law ID: Alloy 52 Model: ASME Section Xi - austenitic stainless steel in air environment dadN = C* I O^F

  • S
  • dKl3.3 here S 1.0 forR<0

= 1.0 + 1.8 *R for0<R<0.79

= -43.5 + 57.97

  • R for 0.79 < R < 1 F = code specified function of temperature dK = Kmax - Kmin R = Kmin / Kmax here:

C

  • lO^F = 1.9352e-010 is for the currently selected units of:

force: kip length: inch temperature: 592.0000 Fahrenheit faterial Fracture Toughness KIc:

Material ID: Alloy 52 Depth Klc 0.0000 200.0000 0.5000 200.0000 2.0000 200.0000 Initial crack size=

0.1000 Max. crack size=

1.0000

Number of blocks=

I Print increment of block=

I Cycles Calc. Print Crk. Grw.

Mat.

Subblock,

/Time incre. incre. Law Klc FCG 1000 10 10 Alloy52 Alloy 52 1

Kmax Kmin ubblock Case ID Scale Factor Case ID Scale Factor CG Residual 1.0000 Residual 1.0000 Operating 1.0000 rack growth results:

Total Subblock Cycles Cycles DaDn

/Time ITime Kmax Kmin DeltaK R

/DaDt Da a

a'thk Block:

I 10 10 4.99e+001 3.74e+001 1.25e+001 0.75 1.88e-006 1.88e-005 0.1 0.05 20 20 4.99e+001 3.74e+001 1.25c+001 0.75 1.88e-006 1.88e-005 0.1 0.05 30 30 4.99e+001 3.74e+001 1.25e+001 0.75 1.88e-006 1.88e-005 0.1001 0.05 40 40 4.99e+001 3.74e+001 1.25e+001 0.75 1.88e-006 1.88e-005 0.1001 0.05 50 50 4.99e+001 3.74e+001 1.25e+001 0.75 1.88e-006 1.88e-005 0.1001 0.05 60 60 4.99e+001 3.74e+001 1.25e+001 0.75 1.88e-006 1.88e-005 0.1001 0.05 70 70 4.99e+001 3.74e+001 1.25e+001 0.75 1.88e-006 1.88e-005 0.1001 0.05 80 80 4.99e+001 3.74e+001 1.25e+001 0.75 1.88e-006 1.88e-005 0.1002 0.05 90 90 4.99e+001 3.74e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1002 0.05 100 100 4.99e+001 3.74e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1002 0.05 110 110 4.99e+00I 3.74e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1002 0.05 120 1204.99e+001 3.75e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1002 0.05 130 1304.99e+001 3.75e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1002 0.05 140 1404.99e+001 3.75e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1003 0.05 150 150 5.00e+001 3.75e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1003 0.05 160 160 5.00e+001 3.75e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1003 0.05 170 170 5.00e+001 3.75e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1003 0.05 180 180 5.00c+001 3.75e+001 1.25e+00l 0.75 1.89e-006 1.89e-005 0.1003 0.05 190 190 5.00e+001 3.75e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1004 0.05 200 200 5.00e+001 3.75e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1004 0.05 210 210 5.00c+001 3.75e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1004 0.05 220 220 5.00e+001 3.75e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1004 0.05 230 230 5.00e+001 3.75e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1004 0.05 240 240 5.00e+001 3.75e+001 1.25e+001 0.75 1.89e-006 1.89e-005 0.1005 0.05 250 250 5.00e+001 3.75e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1005 0.05 Revision 0

1 2

V Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page A17 of A19

260 260 5.OOe+001 3.75e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1005 0.05 270 270 5.00e+001 3.75e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1005 0.05 280 280 5.OOe+001 3.75e+001 1.25e+001 0.75 1.90c-006 1.90e-005 0.1005 0.05 290 290 5.00c+001 3.75e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1005 0.05 300 300 5.00e+001 3.75e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1006 0.05 310 310 5.00e+001 3.75e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1006 0.05 320 320 5.00e+001 3.75e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1006 0.05 330 330 5.OOe+001 3.75e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1006 0.05 340 340 5.00c+001 3.75e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1006 0.05 350 350 5.00e+001 3.75e+001 1.25e+001 0.75 1.90e.006 1.90e-005 0.1007 0.05 360 360 5.01ee+001 3.75e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1007 0.05 370 370 5.01e+001 3.75e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1007 0.05 380 380 5.01e+001 3.75e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1007 0.05 390 390 5.01e+001 3.76e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1007 0.05 400 400 5.01e+001 3.76e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1008 0.05 410 410 5.Ole+001 3.76e+001 1.25e+001 0.75 1.90e-006 1.90e-005 0.1008 0.05 420 420 5.01e+001 3.76e+001 1.25e+001 0.75 1.91e-006 1.91e-005 0.1008 0.05 430 430 5.01e+001 3.76e+001 1.25e+001 0.75 1.91e-006 1.91e-005 0.1008 0.05 440 440 5.01e+001 3.76e+001 1.25e+001 0.75 1.91e.006 1.91e-005 0.1008 0.05 450 450 5.01e+001 3.76e+001 1.25e+001 0.75 1.91e.006 1.9le-005 0.1009 0.05 460 460 5.01e+001 3.76e+001 1.25e+001 0.75 1.91e-006 1.91e-005 0.1009 0.05 470 470 5.01e+001 3.76e+001 1.25e+001 0.75 1.91e-006 I.91e-005 0.1009 0.05 480 480 5.01e+001 3.76e+001 1.25e+001 0.75 1.91e-006 1.91e-005 0.1009 0.05 490 490 5.01e+001 3.76e+001 1.25e+001 0.75 1.91e-006 1.91e-005 0.1009 0.05 500 500 5.01e+001 3.76e+001 1.25e+001 0.75 1.91e-006 1.91e-005 0.1009 0.05 510 510 5.01e+001 3.76e+001 1.25e+001 0.75 1.91e-006 1.91e-005 0.101 0.05 520 520 5.01e+001 3.76e+001 1.25e+001 0.75 1.91e-006 I.91e-005 0.101 0.05 530 530 5.01e+001 3.76e+001 1.25e+001 0.75 1.91e-006 1.91e-005 0.101 0.05 540 540 5.Ole+001 3.76e+001 1.25e+001 0.75 1.91e-006 1.91e-005 0.101 0.05 550 550 5.01e+001 3.76e+001 1.25e+001 0.75 1.91e-006 1.91e-005 0.101 0.05 560 560 5.02e+001 3.76e+001 1.25e+001 0.75 1.91e-006 1.91e-005 0.1011 0.05 570 570 5.02e+001 3.76e+001 1.25e+001 0.75 1.91e-006 1.91e-005 0.1011 0.05 580 580 5.02e+001 3.76e+001 1.25e+001 0.75 1.92e-006 1.92e-005 0.1011 0.05 590 590 5.02e+001 3.76e+001 1.25e+001 0.75 1.92e-006 1.92e-005 0.1011 0.05 600 600 5.02e+001 3.76e+001 1.25e+001 0.75 1.92e-006 1.92e-005 0.1011 0.05 610 610 5.02e+001 3.76e+001 1.25e+001 0.75 1.92e-006 1.92e-005 0.1012 0.05 620 620 5.02e+001 3.76e+001 1.25e+001 0.75 1.92e-006 1.92e-005 0.1012 0.05 630 630 5.02e+001 3.76e+001 1.25e+001 0.75 1.92e-006 1.92e-005 0.1012 0.05 640 640 5.02e+001 3.76e+001 1.25e+001 0.75 1.92e-006 1.92e-005 0.1012 0.05 650 650 5.02e+001 3.76e+001 1.25e+001 0.75 1.92e-006 1.92e-005 0.1012 0.05 660 660 5.02e+001 3.77c+001 1.26e+001 0.75 1.92e-006 1.92e-005 0.1013 0.05 670 670 5.02e+001 3.77e+001 1.26e+001 0.75 1.92e-006 1.92e-005 0.1013 0.05 680 680 5.02e+001 3.77e+001 1.26e+001 0.75 1.92e-006 1.92e-005 0.1013 0.05 690 690 5.02e+001 3.77e+001 1.26e+001 0.75 1.92e-006 1.92e-005 0.1013 0.05 700 700 5.02e+001 3.77e+001 1.26e+001 0.75 1.92e-006 1.92e-005 0.1013 0.05 710 710 5.02e+001 3.77e+001 1.26e+001 0.75 1.92e-006 1.92e-005 0.1014 0.05 720 720 5.02e+001 3.77e+001 1.26e+001 0.75 1.92e-006 1.92e-005 0.1014 0.05 730 730 5.02e+001 3.77e+001 1.26e+001 0.75 1.92e-006 1.92e-005 0.1014 0.05 740 740 5.02e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1014 0.05 Revision 0

1 1

2 V Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5115104 Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page A18 of A19

750 760 770 780 790 800 810 820 830 840 850 860 870 880 890 900 910 920 930 940 950 960 970 980 990 1000 750 5.02e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1014 0.05 760 5.03e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1014 0.05

.770 5.03e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1015 0.05 780 5.03e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1015 0.05 790 5.03e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1015 0.05 800 5.03e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1015 0.05 810 5.03e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1015 0.05 820 5.03e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1016 0.05 830 5.03e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1016 0.05 840 5.03e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1016 0.05 850 5.03e+001 3.77c+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1016 0.05 860 5.03e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1016 0.05 870 5.03e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1017 0.05 880 5.03e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1017 0.05 890 5.03e+001 3.77e+001 1.26e+001 0.75 1.93e-006 1.93e-005 0.1017 0.05 900 5.03e+001 3.77e+001 1.26e+001 0.75 1.94e-006 1.94e-005 0.1017 0.05 910 5.03e+001 3.77e+001 1.26e+001 0.75 1.94e-006 1.94e-005 0.1017 0.05 920 5.03e+001 3.77e+001 1.26e+001 0.75 1.94e-006 1.94c-005 0.1018 0.05 930 5.03e+001 3.78e+001 1.26e+001 0.75 1.94e-006 1.94e-005 0.1018 0.05 940 5.03e+001 3.78e+001 1.26e+001 0.75 1.94e-006 1.94e-005 0.1018 0.05 950 5.03e+001 3.78e+001 1.26e+001 0.75 1.94e-006 1.94e-005 0.1018 0.05 960 5.03e+001 3.78e+001 1.26c+001 0.75 1.94e-006 1.94e-005 0.1018 0.05 970 5.04e+001 3.78e+001 1.26e+001 0.75 1.94e-006 1.94e-005 0.1019 0.05 980 5.04e+001 3.78e+001 1.26e+001 0.75 1.94e-006 1.94e-005 0.1019 0.05 990 5.04e+001 3.78e+001 1.26e+001 0.75 1.94e-006 1.94e-005 0.1019 0.05 1000 5.04e4001 3.78e+001 1.26e+001 0.75 1.94e-006 1.94e-005 0.1019 0.05 End of pc-CRACK Output Revision 0

1 2

Preparer/Date HLG 2/17/04 HLG 5/12/04 HLG 5/15/04 I

Checker/Date GLS 2/17/04 MQ 5/12/04 PCR 5/15/04 File No.

PBCH-09Q-302 Page A19 of A19