3535 Colonnade Parkway Birmingham, AL 35243 205 992 5000 tel Regulatory Affairs March 20, 2025 Docket No.:
50-366 NL-25-0068 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Edwin I. Hatch Nuclear Plant - Unit 2 Cycle 29 Core Operating Limits Report Version 1 Ladies and Gentlemen:
In accordance with Technical Specification 5.6.5.d., Southern Nuclear Operating Company (SNC) submits the enclosed Core Operating Limits Report (COLR), for Edwin I. Hatch Nuclear Plant (HNP) Unit 2 Cycle 29.
The enclosed documentation contains proprietary information as defined by 10 CFR 2.390.
Global Nuclear Fuel (GNF), as the owner of the proprietary information, has executed the enclosed affidavit, which identifies that the enclosed proprietary information has been handled and classified as proprietary, is customarily held in confidence, and has been withheld from public disclosure. The proprietary information was provided to SNC in a GNF transmittal that is referenced by the affidavit. The proprietary information has been faithfully reproduced in the enclosed documentation, such that the affidavit remains applicable. GNF hereby requests that the proprietary information provided in Enclosure 1 to this letter be withheld from public disclosure in accordance with the provisions of 10 CFR 2.390 and 9.17. A non-proprietary version of the COLR is provided as Enclosure 2 to this letter. The affidavit is also provided in to this letter and identifies that the designated information has been handled and classified as proprietary to GNF.
This letter contains no NRC commitments. If you have any questions, please contact Ryan Joyce at 205.992.6468.
Respectfully submitted, Jamie M. Coleman Regulatory Affairs Director JMC/agq/cbg to this letter contains Proprietary Information to be withheld from public disclosure per 10 CFR 2.390. When separated from Enclosure 1 this transmittal document is decontrolled.
U. S. Nuclear Regulatory Commission NL-25-0068 Page 2 of 2
Enclosures:
- 1. HNP Unit 2 Cycle 29 Core Operating Limits Report Version 1 PROPRIETARY INFORMATION and Global Nuclear Fuel - Americas Affidavit
- 2. HNP Unit 2 Cycle 29 Core Operating Limits Report Version 1 NON-PROPRIETARY INFORMATION Cc:
Regional Administrator, Region ll NRR Project Manager - Hatch Senior Resident Inspector - Hatch RTYPE: CHA02.004
Edwin I. Hatch Nuclear Plant - Unit 2 Cycle 29 Core Operating Limits Report Version 1 to NL-25-0068 HNP Unit 2 Cycle 29 Core Operating Limits Report Version 1 NON-PROPRIETARY INFORMATION
Non-Proprietary Information
[Guidance on use of this document is included as hidden text at the end of the document]
SOUTHERN NUCLEAR OPERATING COMPANY EDWIN I. HATCH NUCLEAR PLANT Unit 2 Cycle 29 CORE OPERATING LIMITS REPORT Version 1
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 2
TABLE OF CONTENTS Section Title Page 1.0 Introduction 8
2.0 APLHGR Operating Limits 14 3.0 MCPR Operating Limits 16 4.0 LHGR Operating Limits 56 5.0 Operating Pressure Limits 64 6.0 References 68
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 3
TABLES Table No.
Title Page 1-1 System Operability Requirements 9
1-2 Equipment Requirements 10 1-3 Equipment Condition In/Out of Service Limitations 12 1-4 Exposure Definitions 13 3-1 Cycle-Specific MCPR Safety Limit 19 3-2 Power-Dependent MCPR Limit (MCPRp) Operating Flexibility Options (for Core Power 28% of Rated) 19 3-3 Power-Dependent MCPR Limit Multiplier (Kp) Operating Flexibility Options (for Core Power > 28% of Rated) 20 3-4 Rated-Power OLMCPR Operating Flexibility Options 21 4-1 Rated-Power LHGR Limits versus Peak Pellet Exposure 57 4-2 Power-Dependent LHGR Limit Multiplier (LHGRFACP) Operating Flexibility Options 58 5-1 Pressure-Dependent Operating Flexibility Options 67 5-2 MFLCPR and MFLPD Limits versus Operating Pressure Regions 67
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 4
FIGURES Figure No.
Title Page 2-1 APLHGR Limits versus Average Planar Exposure 15 3-1 Flow-Dependent MCPR Limit (MCPRF) versus Core Flow 23 3-2A Power-Dependent MCPR Limit (MCPRP) versus Core Power 24 3-2B Power-Dependent MCPR Limit (MCPRP) versus Core Power (Main Turbine Bypass System Inoperable) 25 3-3A Power-Dependent MCPR Limit Multiplier (KP) versus Core Power 26 3-3B Power-Dependent MCPR Limit Multiplier (KP) versus Core Power (Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service) 27 3-4A-1 Rated-Power TLO MCPR Limits versus Average SCRAM Time 28 3-4A-2 Rated-Power TLO MCPR Limits versus Average SCRAM Time (Main Turbine Bypass System Inoperable) 29 3-4A-3 Rated-Power TLO MCPR Limits versus Average SCRAM Time (EOC-RPT System Inoperable) 30 3-4A-4 Rated-Power TLO MCPR Limits versus Average SCRAM Time (Main Turbine Bypass System Inoperable &
EOC-RPT System Inoperable) 31 3-4A-5 Rated-Power TLO MCPR Limits versus Average SCRAM Time (Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service) 32
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 5
Figure No.
Title Page 3-4A-6 Rated-Power TLO MCPR Limits versus Average SCRAM Time
([Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service] &
Main Turbine Bypass System Inoperable) 33 3-4A-7 Rated-Power TLO MCPR Limits versus Average SCRAM Time
([Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service] &
EOC-RPT System Inoperable) 34 3-4A-8 Rated-Power TLO MCPR Limits versus Average SCRAM Time
([Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service] &
Main Turbine Bypass System Inoperable &
EOC-RPT System Inoperable) 35 3-4A-9 Rated-Power TLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service) 36 3-4A-10 Rated-Power TLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service &
Main Turbine Bypass System Inoperable) 37 3-4A-11 Rated-Power TLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service & EOC-RPT System Inoperable) 38 3-4A-12 Rated-Power TLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service &
Main Turbine Bypass System Inoperable &
EOC-RPT System Inoperable) 39 3-4B-1 Rated-Power SLO MCPR Limits versus Average SCRAM Time 40 3-4B-2 Rated-Power SLO MCPR Limits versus Average SCRAM Time (Main Turbine Bypass System Inoperable) 41 3-4B-3 Rated-Power SLO MCPR Limits versus Average SCRAM Time (EOC-RPT System Inoperable) 42
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 6
Figure No.
Title Page 3-4B-4 Rated-Power SLO MCPR Limits versus Average SCRAM Time (Main Turbine Bypass System Inoperable &
EOC-RPT System Inoperable) 43 3-4B-5 Rated-Power SLO MCPR Limits versus Average SCRAM Time (Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service) 44 3-4B-6 Rated-Power SLO MCPR Limits versus Average SCRAM Time
([Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service] &
Main Turbine Bypass System Inoperable) 45 3-4B-7 Rated-Power SLO MCPR Limits versus Average SCRAM Time
([Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service] &
EOC-RPT System Inoperable) 46 3-4B-8 Rated-Power SLO MCPR Limits versus Average SCRAM Time
([Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service] &
Main Turbine Bypass System Inoperable &
EOC-RPT System Inoperable) 47 3-4B-9 Rated Power SLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service) 48 3-4B-10 Rated Power SLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service &
Main Turbine Bypass System Inoperable) 49 3-4B-11 Rated Power SLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service & EOC-RPT System Inoperable) 50 3-4B-12 Rated Power SLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service &
Main Turbine Bypass System Inoperable &
EOC-RPT System Inoperable) 51
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 7
Figure No.
Title Page 3-5A High Worth Scram Rod Set - A1 Configuration 52 3-5B High Worth Scram Rod Set - A2 Configuration 53 3-5C High Worth Scram Rod Set - B1a Configuration 54 3-5D High Worth Scram Rod Set - B1b Configuration 55 4-1 Flow-Dependent LHGR Limit Multiplier (LHGRFACF) versus Core Flow 59 4-2A Power-Dependent LHGR Limit Multiplier (LHGRFACP) versus Core Power 60 4-2B Power-Dependent LHGR Limit Multiplier (LHGRFACP) versus Core Power (Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service) 61 4-2C Power-Dependent LHGR Limit Multiplier (LHGRFACP) versus Core Power (High Pressure Feedwater Heaters Out of Service) 62 4-3 Rated-Power LHGR Limit versus Peak Pellet Exposure 63 5-1 Licensed Regions of Operating Dome Pressure versus Core Power 66
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 8
tabcount 1. tablecount figcount 1. figurecount
1.0 INTRODUCTION
The Core Operating Limits Report (COLR) for Plant Hatch Unit 2 Cycle 29 is prepared in accordance with the requirements of Technical Specification 5.6.5. The core operating limits presented herein were developed using NRC-approved methods (Reference 1). This reload includes the GNF3 fuel type (Reference 2). Results from the associated reload analyses for the fuel in Unit 2 Cycle 29 are documented in References 3 through 5.
GNF3 fuel limits in this report are applicable to GNF3 demonstration bundles with aluminosilicate dopant (ASD) fuel (References 3, 4, and 6).
The following core operating limits are included in this report:
- a. Average Planar Linear Heat Generation Rate (APLHGR) - Technical Specification 3.2.1
- b. Minimum Critical Power Ratio (MCPR) - Technical Specification 3.2.2
- c. Linear Heat Generation Rate (LHGR) - Technical Specification 3.2.3 This report also includes limits on the Maximum Fraction of Limiting Critical Power Ratio (MFLCPR) and Maximum Fraction of Limiting Power Density (MFLPD) thermal limit ratios, which may be used in conjunction with the standard core operating limits to allow operation with dome pressure down to 40 psi below nominal.
Related system operability requirements are defined in Table 1-1. Other equipment requirements which must be satisfied for operating limits included in this report to remain applicable are defined in Table 1-2.
Operating limit flexibility options are provided for various equipment in/out of service conditions, dependent on the number of operating recirculation loops, operability of the main turbine bypass system, operability of the End-of-Cycle Recirculation Pump Trip (EOC-RPT) system, status of the main turbine pressure regulator system, status of the moisture separator reheaters, configuration of the high pressure feedwater heaters, and configuration of High Worth Scram Rods (HWSRs). Plant operational limitations associated with specific equipment in/out of service combinations are defined in Table 1-3.
Operating limits are presented in this report as a function of core power, core flow, average scram time, and exposure. These limits are not a function of feedwater temperature. Cycle exposure intervals used in the presentation of limits in this report are defined in Table 1-4.
Operating limits between tabulated values presented in this report are based on linear interpolation.
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 9
TABLE 1-1 System Operability Requirements System Operability Requirement Main Turbine Bypass System Operable (Technical Specification 3.7.7)
At least two bypass valves must be operable
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 10 TABLE 1-2 Equipment Requirements Equipment Requirement Recirculation Flow Control System The maximum achievable core flow on the highest licensed rod line must be limited to less than 112% of rated core flow Turbine Power/Load Unbalance Trip Logic When operating at greater than 55% core thermal power, the turbine Power/Load Unbalance (PLU) trip logic must be functional Feedwater Heaters For any 4th stage feedwater heater configuration off-normal at greater than 43%
core thermal power, High Pressure Feedwater Heaters Out of Service limits must be applied (Unless explicit analysis is performed by BWR Fuel Engineering to demonstrate equipment configuration precludes the Severe Loss of Feedwater Heating event)
APRM System The Oscillation Power Range Monitor (OPRM) Period Based Detection Algorithm (PBDA) amplitude trip setpoint must be set equal to 1.15
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 11 TABLE 1-2 (continued)
Equipment Requirements Equipment Requirement High Worth Scram Rod (HWSR)
An individual High Worth Scram Rod must satisfy the following conditions to be valid for thermal operating limit improvements:
Correspond to a licensed HWSR pattern, as defined in Figure 3-5 series Control rod is inserted to a licensed HWSR notch location, as defined in Figure 3-5 series All diagonal-adjacent and face-adjacent control rods are fully withdrawn as defined by the Figure 3-5 series exclusion regions (Unless explicit analysis is performed by BWR Fuel Engineering to demonstrate thermal limit requirements can still be met)
Control rod scram time is within the scram time requirements specified in Section 3.2 in accordance with Technical Specification Table 3.1.4-1 Moisture Separator Reheaters (MSRs)
When operating above 65% core thermal power, if one or more 2nd stage Moisture Separator Reheater is removed from service or the steam flow path to one or more 2nd stage MSR is potentially reduced relative to normal operation, MSR out of service limits must be applied
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 12 TABLE 1-3 Equipment Condition In/Out of Service Limitations Condition Limitation Single-Loop Operation (SLO)
- Core power must be 2000 MWth
- Core flow must be 55% of rated Main Turbine Bypass System Inoperable OR Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c OR Moisture Separator Reheaters Out of Service OR High Pressure Feedwater Heaters Out of Service Dome pressure must be within +/- 10 psi of nominal, as defined in Figure 5-1 High Pressure Feedwater Heaters Out of Service &
Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c, simultaneously OR High Pressure Feedwater Heaters Out of Service &
Moisture Separator Reheaters Out of Service, simultaneously No core operating limits available (Technical Specifications Required Actions 3.2.2 and 3.2.3 must be entered)
High Worth Scram Rods In Service
- The core must be operating with a set of four (4) valid High Worth Scram Rods (as defined in Table 1-2)
- The Main Turbine Pressure Regulator System Status must be in TLCO 3.3.13.a or TLCO 3.3.13.b
- Moisture Separator Reheaters must be In Service Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c OR Moisture Separator Reheaters Out of Service High Worth Scram Rods In Service core operating limits are NOT applicable
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 13 TABLE 1-4 Exposure Definitions Exposure Label Definition Cycle Exposure BOC Beginning of Cycle Exposure 0 MWd/ST MID1 Cycle Breakpoint Exposure for the Cycle Specific MCPR Safety Limit 7500 MWd/ST MOC1 First Middle of Cycle Exposure EOR - 5500 MWd/ST MOC2 Second Middle of Cycle Exposure EOR - 2000 MWd/ST EOR End of Rated Exposure Projected exposure at end of rated power with all control rods out, rated core flow, and rated feedwater temperature EOC End of Cycle Exposure Exposure at cycle shutdown
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 14 tabcount 2. tablecount figcount 2. figurecount 2.0 APLHGR OPERATING LIMITS For both two loop operation (TLO) and single loop operation (SLO), the APLHGR operating limit for each six inch axial segment of each fuel assembly in the core is the APLHGR limit defined in Figure 2-1.
No flow dependent or power dependent APLHGR limit multipliers (MAPFACF or MAPFACP) are required. For SLO, no unique limit on MAPFACF or MAPFACP is required.
These limits apply to operation over the full range of licensed dome pressure regions shown in Figure 5-1.
(Technical Specification 3.2.1)
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 15 FIGURE 2-1 APLHGR Limits versus Average Planar Exposure Average Planar Exposure (GWd/ST) 0.00 14.36 21.22 13.01 40.82 10.75 57.60 8.00 63.50 6.00 APLHGR Limit (kW/ft) 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 APLHGR Limit (kW/ft)
Average Planar Exposure (GWd/ST)
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 16 tabcount 3. tablecount figcount 3. figurecount 3.0 MCPR OPERATING LIMITS The MCPR operating limit (OLMCPR) for each licensed equipment in or out of service operating flexibility combination is a function of core power, core flow, average scram time, and cycle exposure.
The cycle-specific MCPR safety limits are specified in Table 3-1.
For both two loop operation (TLO) and single loop operation (SLO), the OLMCPR is determined as follows:
- a. For 24% core power 28%, the greater of either:
- 2) The power-dependent MCPR limit, MCPRP, as determined by Table 3-2.
- b. For core power > 28%, the greater of either:
- 1) MCPRF, as determined by Figure 3-1, OR
- 2) The product of the power-dependent MCPR limit multiplier (KP), as determined by Table 3-3, and the scram-time dependent rated-power OLMCPR, as determined by Table 3-4.
The scram-time dependent value of used to determine the rated-power OLMCPR is calculated in accordance with Section 3.1. For High Worth Scram Rods In Service operation, Section 3.2 is also applicable to determine the value of.
Limits for operation with High Worth Scram Rods In Service apply to operation with four valid individual High Worth Scram Rods (HWSRs), as defined in Table 1-3. The licensed sets of HWSRs are defined in the Figure 3-5 series. Individual credited HWSRs must meet the equipment requirements defined in Table 1-2 to be considered valid for thermal operating limit credit. During transition between two HWSR sets defined in the Figure 3-5 series, it is acceptable to continue to credit thermal limits for HWSRs In Service, provided that a minimum of four HWSRs from any of the licensed HWSR sets remain in service at all times.
The limits presented in this section apply to operation with vessel dome pressure within
+/- 10 psi of nominal pressure, as defined by the Region I pressure band shown in Figure 5-1.
With Standard Equipment In Service, with the EOC-RPT System Inoperable, and/or with High Worth Scram Rods In Service, operation with vessel dome pressure down to 40 psi below nominal is licensed provided the additional restrictions identified in Section 5.0 are applied with the OLMCPR defined in this section.
(Technical Specification 3.2.2)
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 17 3.1.
AVERAGE SCRAM TIME REQUIREMENTS In the 3-4A and 3-4B figures, Option A scram time rated-power OLMCPRs correspond to
= 1.0, where is determined from scram time measurements performed in accordance with Technical Specifications 3.1.4 Surveillance Requirement(s). Option B values correspond to
= 0.0. For scram times between Option A and Option B, the rated-power OLMCPR is linearly dependent on. If has not been determined, Option A limits must be used.
The average scram time of the control rods,, is defined as:
= 0, OR B
A B
ave
, whichever is greater.
where:
A
= 1.08 sec (Technical Specification 3.1.4, Table 3.1.4-1, scram time limit to notch 36).
B
=
2 1
n 1
i i
1 N
N
1.65
+
=
where:
= 0.822 sec (mean scram time to notch 36 used in the transient analysis).
= 0.018 sec (standard deviation of ).
1 N = total number of control rods measured in the first surveillance test performed at the beginning of cycle (Technical Specifications SR 3.1.4.1).
n = number of surveillance tests performed to date in the cycle.
i N = number of control rods measured in the ith surveillance test.
ave
=
=
=
n 1
i i
n 1
i i
i N
N where:
i = average scram time to notch 36 of all rods in the ith surveillance test.
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 18 3.2.
HIGH WORTH SCRAM ROD SCRAM TIME REQUIREMENTS For High Worth Scram Rods In Service operation, the value of used to determine the MCPR limit is the greater of either:
- a. The average scram time of the control rods,, as defined in Section 3.1, OR
- b. The maximum of the individually calculated values of for the credited High Worth Scram Rods.
If individually calculated values of for all credited High Worth Scram Rods have not been determined, then non-HWSR limits must be used.
The value of for an individual High Worth Scram Rod is defined as:
= 0, OR HWSR - B A - B
, whichever is greater.
where:
A = as defined in Section 3.1.
B = as defined in Section 3.1.
HWSR = most recent measurement of the individual rod scram time from notch 48 to notch 36 (in seconds).
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 19 TABLE 3-1 Cycle-Specific MCPR Safety Limit Exposure Range Two Loop Operation Single Loop Operation BOC to MID1 1.07 1.08 MID1 to EOC 1.08 1.10 TABLE 3-2 Power-Dependent MCPR Limit (MCPRp) Operating Flexibility Options (for Core Power 28% of Rated)
Equipment In/Out of Service Figure #
Main Turbine Bypass System Operable Yes 3-2A No 3-2B
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 20 TABLE 3-3 Power-Dependent MCPR Limit Multiplier (Kp) Operating Flexibility Options (for Core Power > 28% of Rated)
Equipment In/Out of Service Figure #
Main Turbine Pressure Regulator System Status in TLCO 3.3.13.a or TLCO 3.3.13.b AND Moisture Separator Reheaters In Service Yes 3-3A No 3-3B
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 21 TABLE 3-4 Rated-Power OLMCPR Operating Flexibility Options Equipment In/Out of Service Figure #
TLO SLO Standard Equipment In Service 3-4A-1 3-4B-1 Main Turbine Bypass System Inoperable 3-4A-2 3-4B-2 EOC-RPT System Inoperable 3-4A-3 3-4B-3 Main Turbine Bypass System Inoperable AND EOC-RPT System Inoperable 3-4A-4 3-4B-4 Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service 3-4A-5 3-4B-5 Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service AND Main Turbine Bypass System Inoperable 3-4A-6 3-4B-6 EOC-RPT System Inoperable 3-4A-7 3-4B-7 Main Turbine Bypass System Inoperable AND EOC-RPT System Inoperable 3-4A-8 3-4B-8 High Worth Scram Rods In Service 3-4A-9 3-4B-9 High Worth Scram Rods In Service AND Main Turbine Bypass System Inoperable 3-4A-10 3-4B-10 EOC-RPT System Inoperable 3-4A-11 3-4B-11 Main Turbine Bypass System Inoperable AND EOC-RPT System Inoperable 3-4A-12 3-4B-12
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 22 TABLE 3-4 (continued)
Rated-Power OLMCPR Operating Flexibility Options Equipment In/Out of Service Figure #
TLO SLO High Pressure Feedwater Heaters Out of Service 3-4A-1 3-4B-1 High Pressure Feedwater Heaters Out of Service AND Main Turbine Bypass System Inoperable 3-4A-2 3-4B-2 EOC-RPT System Inoperable 3-4A-3 3-4B-3 Main Turbine Bypass System Inoperable AND EOC-RPT System Inoperable 3-4A-4 3-4B-4 High Pressure Feedwater Heaters Out of Service AND High Worth Scram Rods In Service 3-4A-9 3-4B-9 High Pressure Feedwater Heaters Out of Service AND High Worth Scram Rods In Service AND Main Turbine Bypass System Inoperable 3-4A-10 3-4B-10 EOC-RPT System Inoperable 3-4A-11 3-4B-11 Main Turbine Bypass System Inoperable AND EOC-RPT System Inoperable 3-4A-12 3-4B-12
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 23 FIGURE 3-1 Flow-Dependent MCPR Limit (MCPRF) versus Core Flow Flow (% of Rated)
MCPRF (TLO) 30.0 1.58 93.5 1.20 110.0 1.20 MCPRF(SLO) = MCPRF(TLO) + 0.03 1.10 1.20 1.30 1.40 1.50 1.60 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 Flow-Dependent MCPR Limit (MCPRF)
Core Flow (% of Rated)
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 24 FIGURE 3-2 figurecount FIGURE 3-2A Power-Dependent MCPR Limit (MCPRP) versus Core Power Flow (% of Rated)
Power (% of Rated)
MCPRP (TLO) 24.0 2.40 28.0 2.35 24.0 2.35 28.0 2.35 60.0
< 60.0 MCPRP(SLO) = MCPRP(TLO) + 0.03 2.30 2.40 2.50 2.60 2.70 2.80 24.0 28.0 Power-Dependent MCPR Limit (MCPRP)
Core Power (% of Rated)
Flow 60%
Flow < 60%
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 25 FIGURE 3-2B Power-Dependent MCPR Limit (MCPRP) versus Core Power (Main Turbine Bypass System Inoperable)
Flow (% of Rated)
Power (% of Rated)
MCPRP (TLO) 24.0 2.72 28.0 2.71 24.0 2.64 28.0 2.45 60.0
< 60.0 MCPRP(SLO) = MCPRP(TLO) + 0.03 2.30 2.40 2.50 2.60 2.70 2.80 24.0 28.0 Power-Dependent MCPR Limit (MCPRP)
Core Power (% of Rated)
Flow 60%
Flow < 60%
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 26 FIGURE 3-3 figurecount FIGURE 3-3A Power-Dependent MCPR Limit Multiplier (KP) versus Core Power KP (TLO/SLO)
> 28.0 1.453 40.0 1.318 55.0 1.254
> 55.0 1.150 60.0 1.150 65.0 1.131 85.0 1.060 100.0 1.000 Power (% of Rated) 28 30.0 40.0 50.0 55 60.0 70.0 80.0 90.0 100.0 1.000 1.100 1.200 1.300 1.400 1.500 28.0 Power-Dependent MCPR Limit Multiplier (KP)
Core Power (% of Rated)
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 27 FIGURE 3-3B Power-Dependent MCPR Limit Multiplier (KP) versus Core Power (Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service)
KP (TLO/SLO)
> 28.0 1.453 40.0 1.321 60.0 1.283 85.0 1.195
> 85.0 1.066 100.0 1.000 Power (% of Rated) 28 30.0 40.0 50.0 60.0 70.0 80.0 85 90.0 100.0 1.000 1.100 1.200 1.300 1.400 1.500 28.0 Power-Dependent MCPR Limit Multiplier (KP)
Core Power (% of Rated)
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 28 FIGURE 3-4 figurecount FIGURE 3-4A figurecount FIGURE 3-4A-1 Rated-Power TLO MCPR Limits versus Average SCRAM Time
= 0.0
= 1.0 1.31 1.44 1.37 1.51 1.37 1.51 Rated OLMCPR(TLO)
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC Exposure Range 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 29 FIGURE 3-4A-2 Rated-Power TLO MCPR Limits versus Average SCRAM Time (Main Turbine Bypass System Inoperable)
= 0.0
= 1.0 1.36 1.49 1.39 1.55 1.40 1.56 Exposure Range MOC2 - EOC BOC - MOC1 Rated OLMCPR(TLO)
MOC1 - MOC2 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 30 FIGURE 3-4A-3 Rated-Power TLO MCPR Limits versus Average SCRAM Time (EOC-RPT System Inoperable)
= 0.0
= 1.0 1.33 1.52 1.37 1.56 1.40 1.59 MOC1 - MOC2 MOC2 - EOC BOC - MOC1 Exposure Range Rated OLMCPR(TLO) 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 31 FIGURE 3-4A-4 Rated-Power TLO MCPR Limits versus Average SCRAM Time (Main Turbine Bypass System Inoperable
& EOC-RPT System Inoperable)
= 0.0
= 1.0 1.36 1.54 1.40 1.58 1.45 1.63 Exposure Range Rated OLMCPR(TLO)
MOC2 - EOC MOC1 - MOC2 BOC - MOC1 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 32 FIGURE 3-4A-5 Rated-Power TLO MCPR Limits versus Average SCRAM Time (Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service)
= 0.0
= 1.0 1.33 1.47 1.39 1.53 1.39 1.53 MOC1 - MOC2 MOC2 - EOC BOC - MOC1 Exposure Range Rated OLMCPR(TLO) 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 33 FIGURE 3-4A-6 Rated-Power TLO MCPR Limits versus Average SCRAM Time
([Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service]
& Main Turbine Bypass System Inoperable)
= 0.0
= 1.0 1.36 1.51 1.41 1.57 1.42 1.58 BOC - MOC1 MOC1 - MOC2 MOC2 - EOC Exposure Range Rated OLMCPR(TLO) 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 34 FIGURE 3-4A-7 Rated-Power TLO MCPR Limits versus Average SCRAM Time
([Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service]
& EOC-RPT System Inoperable)
= 0.0
= 1.0 1.35 1.54 1.39 1.58 1.43 1.62 Exposure Range Rated OLMCPR(TLO)
MOC2 - EOC MOC1 - MOC2 BOC - MOC1 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 35 FIGURE 3-4A-8 Rated-Power TLO MCPR Limits versus Average SCRAM Time
([Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service]
& Main Turbine Bypass System Inoperable
& EOC-RPT System Inoperable)
= 0.0
= 1.0 1.38 1.56 1.42 1.60 1.48 1.66 BOC - MOC1 MOC1 - MOC2 MOC2 - EOC Rated OLMCPR(TLO)
Exposure Range 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 36 FIGURE 3-4A-9 Rated-Power TLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service)
= 0.0
= 1.0 1.31 1.44 1.35 1.49 1.35 1.49 Exposure Range Rated OLMCPR(TLO)
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 37 FIGURE 3-4A-10 Rated-Power TLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service
& Main Turbine Bypass System Inoperable)
= 0.0
= 1.0 1.36 1.49 1.38 1.54 1.39 1.54 Exposure Range Rated OLMCPR(TLO)
BOC - MOC1 MOC2 - EOC MOC1 - MOC2 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 38 FIGURE 3-4A-11 Rated-Power TLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service
& EOC-RPT System Inoperable)
= 0.0
= 1.0 1.33 1.52 1.35 1.54 1.35 1.54 Exposure Range Rated OLMCPR(TLO)
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 39 FIGURE 3-4A-12 Rated-Power TLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service
& Main Turbine Bypass System Inoperable
& EOC-RPT System Inoperable)
= 0.0
= 1.0 1.36 1.54 1.40 1.58 1.41 1.61 Exposure Range Rated OLMCPR(TLO)
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 40 FIGURE 3-4B figurecount FIGURE 3-4B-1 Rated-Power SLO MCPR Limits versus Average SCRAM Time
= 0.0
= 1.0 1.42 1.47 1.42 1.54 1.42 1.54 Rated OLMCPR(SLO)
BOC - MOC1 Exposure Range MOC1 - MOC2 MOC2 - EOC 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 41 FIGURE 3-4B-2 Rated-Power SLO MCPR Limits versus Average SCRAM Time (Main Turbine Bypass System Inoperable)
= 0.0
= 1.0 1.42 1.52 1.42 1.58 1.43 1.59 Rated OLMCPR(SLO)
Exposure Range BOC - MOC1 MOC1 - MOC2 MOC2 - EOC 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 42 FIGURE 3-4B-3 Rated-Power SLO MCPR Limits versus Average SCRAM Time (EOC-RPT System Inoperable)
= 0.0
= 1.0 1.42 1.55 1.42 1.59 1.43 1.62 Exposure Range Rated OLMCPR(SLO)
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 43 FIGURE 3-4B-4 Rated-Power SLO MCPR Limits versus Average SCRAM Time (Main Turbine Bypass System Inoperable
& EOC-RPT System Inoperable)
= 0.0
= 1.0 1.42 1.57 1.43 1.61 1.48 1.66 Exposure Range Rated OLMCPR(SLO)
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 44 FIGURE 3-4B-5 Rated-Power SLO MCPR Limits versus Average SCRAM Time (Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service)
= 0.0
= 1.0 1.42 1.50 1.42 1.56 1.42 1.56 Exposure Range Rated OLMCPR(SLO)
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 45 FIGURE 3-4B-6 Rated-Power SLO MCPR Limits versus Average SCRAM Time
([Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service]
& Main Turbine Bypass System Inoperable)
= 0.0
= 1.0 1.42 1.54 1.44 1.60 1.45 1.61 Exposure Range Rated OLMCPR(SLO)
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 46 FIGURE 3-4B-7 Rated-Power SLO MCPR Limits versus Average SCRAM Time
([Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service]
& EOC-RPT System Inoperable)
= 0.0
= 1.0 1.42 1.57 1.42 1.61 1.46 1.65 Exposure Range Rated OLMCPR(SLO)
BOC - MOC1 MOC2 - EOC MOC1 - MOC2 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 47 FIGURE 3-4B-8 Rated-Power SLO MCPR Limits versus Average SCRAM Time
([Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service]
& Main Turbine Bypass System Inoperable
& EOC-RPT System Inoperable)
= 0.0
= 1.0 1.42 1.59 1.45 1.63 1.51 1.69 Rated OLMCPR(SLO)
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC Exposure Range 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 48 FIGURE 3-4B-9 Rated Power SLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service)
= 0.0
= 1.0 1.42 1.47 1.42 1.52 1.42 1.52 Exposure Range Rated OLMCPR(SLO)
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 49 FIGURE 3-4B-10 Rated Power SLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service
& Main Turbine Bypass System Inoperable)
= 0.0
= 1.0 1.42 1.52 1.42 1.57 1.42 1.57 Exposure Range Rated OLMCPR(SLO)
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 50 FIGURE 3-4B-11 Rated Power SLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service
& EOC-RPT System Inoperable)
= 0.0
= 1.0 1.42 1.55 1.42 1.57 1.42 1.57 Exposure Range Rated OLMCPR(SLO)
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 51 FIGURE 3-4B-12 Rated Power SLO MCPR Limits versus Average SCRAM Time (High Worth Scram Rods In Service
& Main Turbine Bypass System Inoperable
& EOC-RPT System Inoperable)
= 0.0
= 1.0 1.42 1.57 1.43 1.61 1.44 1.64 MOC1 - MOC2 MOC2 - EOC Exposure Range Rated OLMCPR(SLO)
BOC - MOC1 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.30 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 0.0 0.2 0.4 0.6 0.8 1.0 MCPR Limit MCPR Limit
BOC - MOC1 MOC1 - MOC2 MOC2 - EOC
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 52 FIGURE 3-5 figurecount FIGURE 3-5A High Worth Scram Rod Set - A1 Configuration 02 06 10 14 18 22 26 30 34 38 42 46 50 51 51 47 47 43 43 39
+
+
39 35 35 31 31 27 27 23 23 19 19 15
+
+
15 11 11 07 07 03 03 02 06 10 14 18 22 26 30 34 38 42 46 50 Licensed High Worth Scram Rod:
+
High Worth Scram Rod Exclusion Region:
Maximum High Worth Scram Rod Depth (Notch):
32 Minimum High Worth Scram Rod Depth (Notch):
36 Licensed HWSR Coordinates (IX-JY) 14-15 14-39 38-15 38-39 Notch 00 02 04 06 08 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Notch HWSR Depths Inserted Withdrawn Licensed
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 53 FIGURE 3-5B High Worth Scram Rod Set - A2 Configuration 02 06 10 14 18 22 26 30 34 38 42 46 50 51 51 47 47 43
+
43 39 39 35 35 31 31 27
+
+
27 23 23 19 19 15 15 11
+
11 07 07 03 03 02 06 10 14 18 22 26 30 34 38 42 46 50 Licensed High Worth Scram Rod:
+
High Worth Scram Rod Exclusion Region:
Maximum High Worth Scram Rod Depth (Notch):
32 Minimum High Worth Scram Rod Depth (Notch):
36 Licensed HWSR Coordinates (IX-JY) 10-27 26-11 26-43 42-27 Notch 00 02 04 06 08 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Notch HWSR Depths Inserted Withdrawn Licensed
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 54 FIGURE 3-5C High Worth Scram Rod Set - B1a Configuration 02 06 10 14 18 22 26 30 34 38 42 46 50 51 51 47 47 43 43 39 39 35 35 31
+
+
31 27 27 23
+
+
23 19 19 15 15 11 11 07 07 03 03 02 06 10 14 18 22 26 30 34 38 42 46 50 Licensed High Worth Scram Rod:
+
High Worth Scram Rod Exclusion Region:
Maximum High Worth Scram Rod Depth (Notch):
32 Minimum High Worth Scram Rod Depth (Notch):
36 Licensed HWSR Coordinates (IX-JY) 10-31 10-23 42-31 42-23 Notch 00 02 04 06 08 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Notch HWSR Depths Inserted Withdrawn Licensed
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 55 FIGURE 3-5D High Worth Scram Rod Set - B1b Configuration 02 06 10 14 18 22 26 30 34 38 42 46 50 51 51 47 47 43 43 39
+
+
39 35 35 31 31 27 27 23 23 19 19 15
+
+
15 11 11 07 07 03 03 02 06 10 14 18 22 26 30 34 38 42 46 50 Licensed High Worth Scram Rod:
+
High Worth Scram Rod Exclusion Region:
Maximum High Worth Scram Rod Depth (Notch):
32 Minimum High Worth Scram Rod Depth (Notch):
36 Licensed HWSR Coordinates (IX-JY) 10-39 10-15 42-39 42-15 Notch 00 02 04 06 08 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Notch HWSR Depths Inserted Withdrawn Licensed
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 56 tabcount 4. tablecount figcount 4. figurecount 4.0 LHGR OPERATING LIMITS The LHGR operating limit for each licensed equipment in or out of service operating flexibility combination is independent of average scram time, and is a function of fuel rod type, core power, core flow, cycle exposure, and pellet exposure.
For both two loop operation (TLO) and single loop operation (SLO), the LHGR operating limit for each six inch axial segment of each fuel rod in the core is the applicable rated-power, rated-flow LHGR limit taken from Table 4-1 multiplied by the smaller of either:
- b. The power-dependent LHGR limit multiplier, LHGRFACP, as determined by Table 4-2.
Table 4-1 shows the exposure-dependent LHGR limits as a function of initial gadolinia concentration in a six inch segment of a fuel rod. Figure 4-3 shows the LHGR limits for both UO2 fuel segments and for fuel segments with the highest initial Gd (Gd2O3) concentrations.
These limits apply to operation with vessel dome pressure within +/- 10 psi of nominal pressure, as defined by the Region I pressure band shown in Figure 5-1. With Standard Equipment In Service, with the EOC-RPT System Inoperable, and/or with High Worth Scram Rods In Service, operation with vessel dome pressure down to 40 psi below nominal is licensed provided the additional restrictions identified in Section 5.0 are applied with the LHGR operating limit defined in this section.
(Technical Specification 3.2.3)
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 57 TABLE 4-1 Rated-Power LHGR Limits versus Peak Pellet Exposure
((
` ` ` ` ` ` ` ` ` ` ` ` ` ` ` ` ` ` ` ` ` ` ` ` ` ` `
))
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 58 TABLE 4-2 Power-Dependent LHGR Limit Multiplier (LHGRFACP) Operating Flexibility Options Equipment In/Out of Service Figure #
Main Turbine Pressure Regulator System Status in TLCO 3.3.13.a or TLCO 3.3.13.b AND Moisture Separator Reheaters In Service High Pressure Feedwater Heaters In Service Yes Yes 4-2A No 4-2C No Yes 4-2B No Not Licensed
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 59 FIGURE 4-1 Flow-Dependent LHGR Limit Multiplier (LHGRFACF) versus Core Flow Flow (% of Rated)
LHGRFACF (TLO/SLO) 30.0 0.538 40.0 0.680 50.0 0.762 60.0 0.830 85.0 1.000 110.0 1.000 0.400 0.500 0.600 0.700 0.800 0.900 1.000 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 Flow-Dependent LHGR Multiplier (LHGRFACF)
Core Flow (% of Rated)
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 60 FIGURE 4-2 FIGURE 4-2A Power-Dependent LHGR Limit Multiplier (LHGRFACP) versus Core Power 24.0 28.0
> 28.0 100.0 Power (% of Rated)
LHGRFACP (TLO/SLO) 0.450 0.450 0.623 1.000 24 28 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 0.400 0.500 0.600 0.700 0.800 0.900 1.000 24.0 Power-Dependent LHGR Multiplier (LHGRFACP)
Core Power (% of Rated)
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 61 FIGURE 4-2B Power-Dependent LHGR Limit Multiplier (LHGRFACP) versus Core Power (Main Turbine Pressure Regulator System Status in TLCO 3.3.13.c AND/OR Moisture Separator Reheaters Out of Service) 24.0 28.0
> 28.0 45.0 100.0 Power (% of Rated)
LHGRFACP (TLO/SLO) 0.415 0.445 0.583 0.712 1.000 24 28 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 0.400 0.500 0.600 0.700 0.800 0.900 1.000 24.0 Power-Dependent LHGR Multiplier (LHGRFACP)
Core Power (% of Rated)
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 62 FIGURE 4-2C Power-Dependent LHGR Limit Multiplier (LHGRFACP) versus Core Power (High Pressure Feedwater Heaters Out of Service)
LHGRFACP (TLO/SLO)
LHGRFACP (TLO/SLO) 24.0 0.450 24.0 0.450 28.0 0.450 28.0 0.450
> 28.0 0.623
> 28.0 0.623 43.1 0.702 72.3 0.855 80.0 0.702 85.0 0.855 85.0 0.754 89.0 0.942 90.0 0.839 100.0 1.000 95.0 0.924 100.0 1.000 Power (% of Rated)
Power (% of Rated)
BOC - EOR EOR - EOC 24 28 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 0.400 0.500 0.600 0.700 0.800 0.900 1.000 24.0 Power-Dependent LHGR Multiplier (LHGRFACP)
Core Power (% of Rated)
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 63
((
` ` ` ` ))
FIGURE 4-3 Rated-Power LHGR Limit versus Peak Pellet Exposure
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 64 5.0 OPERATING PRESSURE LIMITS The operating limits presented within this report require that reactor dome pressure be maintained within the licensed pressure bands defined by Figure 5-1. For operation in each of these regions, the following pressure dependent restrictions apply:
- a. For Region I operation:
The core operating limits from Sections 2.0 through 4.0 are applicable.
- b. For Region II and Region III operation:
- 1) The core operating limits from Sections 2.0 through 4.0 are applicable AND
- 2) The MFLCPR and MFLPD thermal limit ratios must remain below the maximum values determined by Table 5-1.
These restrictions are independent of core power, core flow, cycle exposure, feedwater temperature, the number of operating recirculation loops, and average scram time.
The pressure-dependent MFLPD and MFLCPR limits defined in this section constitute redefinitions of the conditions for entry into Technical Specifications Required Action Statements 3.2.2 and 3.2.3. Thus, any additional applicable administrative limits beyond those discussed in this section must be applied in combination (via multiplication) to maintain margin to the COLR-based thermal limit ratio limits instead of margin to MFLCPR and/or MFLPD thermal limit ratio values of 1.000.
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 65 5.1.
THERMAL LIMIT RATIO DEFINITIONS The MFLCPR and MFLPD thermal limit ratios are defined in terms of the core operating limits defined in Section 3.0 and Section 4.0.
The MFLCPR thermal limit ratio is the most limiting (maximum) value of the Fraction of Limiting Critical Power Ratio (FLCPR) in the core. The FLCPR is defined for each fuel assembly in the core as:
FLCPR
=
MCPRLimit Fuel Assembly Critical Power Ratio where:
MCPRLimit
=
MCPR operating limit defined in Section 3.0 The MFLPD thermal limit ratio is the most limiting (maximum) value of the Fraction of Limiting Power Density (FLPD) in the core. The FLPD is defined for each six inch axial segment of each fuel rod in the core as:
FLPD
=
Peak kW/ft power generated in a fuel rod segment LHGRLimit where:
LHGRLimit
=
LHGR operating limit defined in Section 4.0
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 66 FIGURE 5-1 Licensed Regions of Operating Dome Pressure versus Core Power
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 67 tabcount 5.
TABLE 5-1 Pressure-Dependent Operating Flexibility Options Equipment In/Out of Service Table #
Main Turbine Bypass System Operable Main Turbine Pressure Regulator System Status in TLCO 3.3.13.a or in TLCO 3.3.13.b AND Moisture Separator Reheaters In Service High Pressure Feedwater Heaters In Service Yes Yes Yes 5-2 Reduced-Pressure Flexibility Option is Not Licensed if any of the three categories in this Table are answered NO.
Not Licensed TABLE 5-2 MFLCPR and MFLPD Limits versus Operating Pressure Regions Operating Pressure Region Maximum Allowable Thermal Limit Ratio MFLCPR Limit MFLPD Limit I
1.000 1.000 II 0.980 1.000 III 0.950 0.920
Plant Hatch Core Operating Limits Report Unit 2 Cycle 29 Non-Proprietary Information Version 1 68 tabcount 6. tablecount figcount 6. figurecount
6.0 REFERENCES
- 1. Global Nuclear Fuel Report NEDE-24011-P-A-32, "General Electric Standard Application for Reactor Fuel (GESTAR II)," August 2024, and the US Supplement, NEDE-24011-P-A-32-US, August 2024.
- 2. Global Nuclear Fuel Report NEDC-33879P, "GNF3 Generic Compliance with NEDE-24011-P-A (GESTAR II)," Revision 5, August 2024.
- 3. Southern Nuclear Operating Company Report NF-24-014, "Hatch-2 Cycle 29 Reload Licensing Analysis Report," Version 2, January 2025.
- 4. Global Nuclear Fuel Report 007N9077, "Supplemental Reload Licensing Report for Hatch 2 Reload 28 Cycle 29," Revision 0, November 2024.
- 5. Global Nuclear Fuel Report 007N9078, "Fuel Bundle Information Report for Hatch 2 Reload 28 Cycle 29," Revision 0, November 2024.
- 6. Global Nuclear Fuel Report 008N4603, GNF3 Fuel Design with Aluminosilicate Dopant Fuel (Four Demonstration Bundles) Analyses for Edwin I. Hatch Nuclear Plant Unit 2 Cycle 29, Revision 0, October 2024.