Response to NuScale Topical Report Audit Question Question Number: A-FSR.LTR-27 Receipt Date: 10/14/2024 Question:

Where do the values in Table 6-5 come from? Are they BU dependent? How are they conservative?

Response

The (( [

]2(a),(c) presented in Table 6-5 are developed from (( }}2(a),(c) These codes are found acceptable for application to the NuScale reactor in TR-0616-48793-P-A, Nuclear Analysis Codes and Methods Qualification, Revision 1. The operating parameters in Table 6-5 are the (( }}2(a),(c) The additional bias is shown in Table 1 below: Table 1: Bias Treatment for Operating Parameter Axial Distributions Parameter Bias Treatment Bias Value (( }}2(a),(c) NuScale Nonproprietary NuScale Nonproprietary

(( }}2(a),(c) No changes to the LTR are necessary. NuScale Nonproprietary NuScale Nonproprietary}}