DCL-25-007, Response to Request for Additional Information for License Amendment Request 24-02, Request for Approval of DCPP Early Warning System to Meet 10 CFR 73.55(i)(2) and 10 CFR 73.55(e)(9)(vi)(A)

From kanterella
(Redirected from ML25035A319)
Jump to navigation Jump to search

Response to Request for Additional Information for License Amendment Request 24-02, Request for Approval of DCPP Early Warning System to Meet 10 CFR 73.55(i)(2) and 10 CFR 73.55(e)(9)(vi)(A)
ML25035A319
Person / Time
Site: Diablo Canyon  
(SNM-2011, DPR-080, DPR-082)
Issue date: 02/04/2025
From: Peck A
Pacific Gas & Electric Co
To:
Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation, Document Control Desk
Shared Package
ML25037A007 List:
References
DCL-25-007
Download: ML25035A319 (1)


Text

Security-Related Information - Withhold under 10 CFR 2.390 Adam S. Peck Site Vice President Diablo Canyon Power Plant Mail code 104/6/605 P.O. Box 56 Avila Beach, CA 93424 805.545.6675 Adam.Peck@pge.com A member of the STARS (Strategic Teaming and Resource Sharing) Alliance Callaway

  • Diablo Canyon
  • Palo Verde
  • Wolf Creek THE ENCLOSURE OF THIS LETTER CONTAINS SECURITY-RELATED INFORMATION. THIS INFORMATION MUST BE PROTECTED ACCORDINGLY. UPON REMOVAL OF THE ENCLOSURE, THIS LETTER IS DECONTROLLED 10 CFR 50.90 10 CFR 73.5 10 CFR 73.55(r)

PG&E Letter DCL-25-007 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Diablo Canyon Units 1 and 2 Docket No. 50-275, OL-DPR-80 Docket No. 50-323, OL-DPR-82 Materials License No. SNM-2511, Docket No. 72-26 Diablo Canyon Independent Spent Fuel Storage Installation Response to Request for Additional Information for License Amendment Request 24-02, Request for Approval of DCPP Early Warning System to Meet 10 CFR 73.55(i)(2) and 10 CFR 73.55(e)(9)(vi)(A)

Reference 1: PG&E Letter DCL-24-040, License Amendment Request 24-02, Request for Approval of DCPP Early Warning System To Meet 10 CFR 73.55(i)(2) and 10 CFR 73.55(e)(9)(vi)(A), dated April 15, 2024 (ADAMS Accession No. ML24108A113) 2: NRC Letter Diablo Canyon Nuclear Power Plant, Units 1 and 2 -

Request for Additional Information Re: Alternative Security Measures for the Early Warning System, dated December 5, 2024 (ADAMS Accession No. ML24318C482)

Dear Commissioners and Staff:

Pursuant to 10 CFR 50.90, Pacific Gas and Electric Company (PG&E) submitted Reference 1 that requested approval of a proposed amendment to Facility Operating License Nos. DPR-80 and DPR-82 for Diablo Canyon Power Plant Units 1 and 2, respectively. The license amendment request (LAR) proposes alternative security measures for the implementation of the Early Warning System in accordance with 10 CFR 73.55(r). Exemption from 10 CFR 73.55(e)(9)(vi)(A) is also requested in accordance with 10 CFR 73.5.

m Pacific Gas and Electric Company*

Security-Related Information - Withhold under 10 CFR 2.390 Document Control Desk PG&E Letter DCL-25-007 Page 2 A member of the STARS (Strategic Teaming and Resource Sharing) Alliance Callaway

  • Diablo Canyon
  • Palo Verde
  • Wolf Creek THE ENCLOSURE OF THIS LETTER CONTAINS SECURITY-RELATED INFORMATION. THIS INFORMATION MUST BE PROTECTED ACCORDINGLY. UPON REMOVAL OF THE ENCLOSURE, THIS LETTER IS DECONTROLLED In Reference 2, the NRC provided a request for additional information for the Reference 1 LAR. The Enclosure provides a response to the requested additional information This submittal contains security-related information and is being protected pursuant to 10 CFR 2.390. The affected attachment has been identified and marked to reflect it contains security-related information.

PG&E makes no new or revised regulatory commitments (as defined by NEI 99-04) in this submittal.

Pursuant to 10 CFR 50.91, PG&E is sending a copy of this proposed amendment to the California Department of Public Health.

If you have any questions or require additional information, please contact Mr. James Morris, Regulatory Services Manager, at 805-545-4609.

I state under penalty of perjury that the foregoing is true and correct.

Sincerely, Adam S. Peck Date Site Vice President misf/51222953-2 Enclosure cc:

Diablo Distribution cc/enc (without Enclosure Attachment 1)

Anthony Chu, Division Chief, California Department of Public Health Mahdi O. Hayes, NRC Senior Resident Inspector Samson S. Lee, NRR Project Manager John D. Monninger, NRC Region IV Administrator February 4, 2025

\

'\