ML24346A187

From kanterella
Jump to navigation Jump to search
LLC - Response to SDAA Audit Question Number A-4.5.2-4
ML24346A187
Person / Time
Site: 05200050
Issue date: 12/11/2024
From:
NuScale
To:
Office of Nuclear Reactor Regulation
Shared Package
ML24346A130 List: ... further results
References
LO-175762
Download: ML24346A187 (1)


Text

Response to SDAA Audit Question Question Number: A-4.5.2-4 Receipt Date: 05/06/2024 Question:

The response to audit issue A-04.05.02-1_1 includes an updated Table 4.5.2 with RVI components and alloys/grades listed for each one. One entry, for the Upper riser bellows and RVI injection line, lists the material as "Corrosion resistant stainless steel or nickel-based alloy" and the ASME Codes and Code Cases that these alloys will comply. In order for the staff to make a safety finding on the material, NuScale should either specify an alloy for each of these two components in the SDA or these components should be designated to be completed as COL items. If a nickel-base alloy or non-austenitic stainless steel is chosen in the SDA, then discussion of this alloy should be included in the Other Materials section of 4.5.2, as designated in the SRP.

Response

Final Safety Analysis Report Table 4.5-2 is updated to revise the list of materials, including alloys, for use with the reactor vessel internals injection line and upper riser bellows.

Markups of the affected changes, as described in the response, are provided below:

NuScale Nonproprietary NuScale Nonproprietary

NuScale Final Safety Analysis Report Reactor Materials NuScale US460 SDAA 4.5-8 Draft Revision 2 Audit Question A-4.5.1-3, Audit Question A-4.5.2-1, Audit Question A-4.5.2-4 Table 4.5-2: Reactor Vessel Internals Materials Component Specification Material (Grade, Class, or Type)

Lower Internals Core barrel SA-965 F304 (Note 1)

Reflector blocks SA-965 SA-182 F304 (Note 1)

Lower core plate Core support mounting bracket gussets SA-240 Type 304 (Note 1)

Upper support blocks SA-479 SA-240 Type 304 (Note 1)

Core support mounting bracket top plates SA-182 F304 (Note 1)

Fuel pins SA-479 Type 304 (Note 1)

Threaded inserts Retaining rings SA-479 UNS S21800 Incore instrument guide tubes SA-213 TP304 (Note 1)

Lower riser section Incore instrument funnel Control rod assembly (CRA) alignment cone, cards, and flanges CRA guide tube support plate SA-240 Type 304 (Note 1)

Upper core plate SA-240 Type 304 (Note 1)

SA-965 F304 (Note 1)

CRA guide tubes SA-312 TP304 (Note 1)

Fuel pins and fuel pin caps SA-479 Type 304 (Note 1)

Upper Internals Upper riser hanger plate and washers Upper riser and transition shells CRDS installation blocks, wedges, and shims CRDS support plates Incore instrument guide tube retaining plates SA-240 Type 304 (Note 1)

Upper riser bellows RVI injection line SA-240 SA-479 A-580 Type 304 (Note 1)

SA-312 TP304 SMLS (Note 1)

SA-249 A-249 TP321 SA-182 F304 (Note 1)

Guide tube riser sleeve SA-312 TP304 SMLS (Note 1)

CRD shaft sleeves SA-213 TP304 (Note 1)

SA-479 Type 304 (Note 1)

Incore instrument guide tubes Level sensor guide tubes SA-213 TP304 (Note 1)

Threaded rods Threaded inserts Piping strap SA-479 Type 304 (Note 1)

NuScale Final Safety Analysis Report Reactor Materials NuScale US460 SDAA 4.5-9 Draft Revision 2 RVI Fasteners Screws, cap screws, set screws, studs, nuts, dowels, pins, and alignment pins SA-479 Type 304 XM-19 UNS S21800 SA-479 Type 316 strain hardened Weld Filler Metals for RVI Austenitic stainless steel weld filler metals SFA-5.4 E308, E308L, E316, E316L (Note 2)

SFA-5.9 ER308, ER308L, ER316, ER316L (Note 2)

SFA-5.22 E308, E308L, E316, E316L (Note 2)

Notes:

(1) 0.03% maximum carbon for unstabilized AISI Type 3XX base metals if welded or exposed to temperature range of 800°F to 1500°F subsequent to final solution anneal.

(2) 0.03% maximum carbon for unstabilized AISI Type 3XX weld filler metals; ferrite number in the range of 5FN to 20FN, except 5FN to 16FN for Type 316 and Type 316L.

Table 4.5-2: Reactor Vessel Internals Materials (Continued)

Component Specification Material (Grade, Class, or Type)