Response to SDAA Audit Question Question Number: A-4.3-25 Receipt Date: 06/03/2024 Question:

Please provide for audit the engineering drawing of the reflector design that includes the geometric distribution of the holes in the reflector. In the response to audit question A-4.3-10, the applicant provides information on the number and size of the holes in the reflector but not the geometric distribution.

Response

ED-121466, Revision 1, Reflector Block Intermediate and ED-121467, Revision 1, Reflector Block Bottom provide the geometric design of the holes in the reflector. ED-121466 and ED-121467 are provided in the eRR as part of this response.

No changes to the SDAA are necessary.