ENCLOSURE 1 M240233 Open Session Presentation Slides for RAJ-II Meeting Non-Proprietary Information
SHIPMENT OF LEAD USE ASSEMBLIES IN THE RAJ-II PACKAGE Presentation to the NRC November 13, 2024 Non-Proprietary Information
2 Agenda and Speakers Meeting to discuss the need for a Letter Authorization to allow shipment of a new fuel design as LUAs Open Session:
Overview of the LUA Design - Weston Cundiff Overview of the RAJ-II Package - Jess Gee Closed Session:
Proprietary Overview of the LUA Design - Weston Cundiff Comparison of the LUA Design to the Current RAJ-II CoC - Jess Gee Discussion of Letter Authorization SAR Contents - Jess Gee GNF Schedule Requests - Jess Gee Non-Proprietary Information
OVERVIEW OF THE LUA DESIGN Non-Proprietary Information
4 Non-Proprietary Information LUA Purpose & Design Overview
- Lead Use Assembly (LUA) Definition: Pre-production prototype of a new fuel design, which contains a new design features that are distinctly different from previous fuel designs.
- Purpose of LUAs: Confirm expected operation of a new fuel design rather than to gather specific technical information.
- New Fuel Design:
- 11x11 fuel matrix
- Utilizes currently used and/or approved materials
- Mechanical design similar to current GNF fuel products
OVERVIEW OF THE RAJ-II PACKAGE Non-Proprietary Information
6 Non-Proprietary Information Overview of the RAJ-II Package
- Certificate of Compliance (CoC) USA/9309/B(U)F-96, Revision 14
- NRC approved for Type B fissile material up to 8 wt% 235U
- Composed of an Outer Container (OC) and Inner Container (IC)
- Stainless Steel (SS) OC body and lid, with impact absorbers
- Inner container contains cavities to hold up to two fuel assemblies, or loose rods
- Fuel rod cladding and welded end plugs act as primary containment
END OF OPEN SESSION Non-Proprietary Information