ML24323A047

From kanterella
Jump to navigation Jump to search

Summary of November 12, 2024, Pre-Submittal Meeting with Framatome Inc. and the U.S. Nuclear Regulatory Commission for Topical Report, ANP-10323PA, Revision 1, Supplement 1, Galileo Fuel Rod Thermal-Mechanical Methodology for Pressurized Wa
ML24323A047
Person / Time
Site: 99902041
Issue date: 11/21/2024
From: Ngola Otto
Licensing Processes Branch
To: Gerond George
Licensing Processes Branch
Shared Package
ML24312A023 List:
References
EPID L-2024-LRM-0109
Download: ML24323A047 (1)


Text

November 21, 2024 MEMORANDUM TO: Gerond A. George, Chief Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM:

Ngola A. Otto, Project Manager /RA/

Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

SUBJECT:

SUMMARY

OF NOVEMBER 12, 2024, PRE-SUBMITTAL MEETING WITH FRAMATOME INC. AND THE U.S. NUCLEAR REGULATORY COMMISSION FOR TOPICAL REPORT, ANP-10323PA, REVISION 1, SUPPLEMENT 1, GALILEO FUEL ROD THERMAL-MECHANICAL METHODOLOGY FOR PRESSURIZED WATER REACTOR (EPID L-2024-LRM-0109)

On November 12, 2024, the U.S. Nuclear Regulatory Commission (NRC) staff held a partially closed meeting via Microsoft Teams with representatives from Framatome Inc. (Framatome).

The purpose of this meeting was for the NRC staff to hold pre-submittal discussions for Framatome ANP-10232PA, Revision 1, Supplement 1, GALILEO Fuel Rod Thermal-Mechanical Methodology for Pressurized Water Reactor [PWR], topical report (TR). The meeting notice dated October 16, 2024, and all associated information are available in the Agencywide Documents Access and Management System (ADAMS) at Package Accession No. ML24312A023.

During the open session, the Framatome representatives provided background information for the development of Supplement 1 to TR ANP-10232P, Revision 1, which was reviewed and approved by the NRC staff in November 2020 (ADAMS Package Accession No. ML20304A661). More specific, the Framatome representative explained that 1) an alternate application methodology for the GALILEO advanced fuel performance models was created in the development of Supplement 1, and that 2) Supplement 1 would replace legacy fuel performance models that can be incorporated into utility-specific reload design process. There were no members of the public at the meeting.

CONTACT: Ngola Otto, NRR/DORL 301-415-6695

During the closed session, details on the scope of the TR, methodologies, test cases, and results were provided. Regarding the scope of the planned submittal, the Framatome representative explained that new methods were developed for rod internal pressure (RIP), clad oxide thickness, fuel centerline melt (FCM), and transient cladding strain (TCS) design criteria.

Also, in Supplement 1, Framatome representative emphasized that there would not be any change in the thermal and mechanical models established in GALILEO, creep collapse, clad fatigue, clad stress, and ARCADIA rod ejection accident inputs. In summary, Framatome representatives stated in part that, they are 1) determined to drive the shift from legacy codes and methods to advanced solutions to meet customers needs; 2) Supplement 1 applies approved fuel performance methods for a simpler application of the GALILEO code for RIP, clad oxide thickness, FCM, and TCS; and 3) test cases show results are within expected ranges.

Several NRC staff questions were addressed during the discussions. In closing, there were discussions on the next steps and planned submittal schedule.

Docket No. 99902041

Enclosure:

List of Attendees

Enclosure List of Attendees Partially - Closed Meeting between Framatome Inc. and the U.S. Nuclear Regulatory Commission on Topical Report ANP-10323P, Revision 1, Supplement 1, GALILEO Fuel Rod Thermal-Mechanical Methodology for Pressurized Water Reactors November 12, 2024 10:30 am - 12:00 pm NAME ORGANIZATION Morris Byram Framatome Inc. (Framatome)

Heather Weiss Framatome Sun Miao Framatome Chris Allison Framatome Jerald Holm Framatome Jackie Stevens Framatome Philippe Bellanger Framatome Joseph Messina U. S. Nuclear Regulatory Commission (NRC)

Patrick Raynaud NRC Ngola Otto NRC

ML24312A023 (Package)

ML24323A047 (Summary)

ML24312A020 (Presentation - Non-Proprietary)

ML24312A019 (Presentation - Proprietary)

ML24318C459 (Affidavit)

  • via email OFFICE NRR/DORL/LLPB/PM*

NRR/DORL/LLPB/LA*

NRR/DORL/LLPB/BC*

NRR/DORL/LLPB/PM*

NAME Notto DHarrison GGeorge NOtto DATE 11/12/2024 11/21/2024 11/21 /2024 11/21/2024