UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Richard W. Boyle, Chief Radioactive Materials Branch U.S. Department of Transportation 1200 New Jersey Avenue SE Washington, D.C. 20590
SUBJECT:
REQUEST FOR REVALIDATION OF FRENCH CERTIFICATE OF APPROVAL F/410/B(U)-96 FOR THE MODEL NO. MANON PACKAGE, DOCKET NO. 71-3094
Dear Richard Boyle:
By letter dated April 6, 2023 (Agencywide Documents Access and Management System
[ADAMS] Accession No. ML23251A205) as supplemented on April 24, 2024 (ML24312A201),
the U.S. Department of Transportation requested that the U.S. Nuclear Regulatory Commission (NRC) staff perform a review of the Certificate of Competent Authority No. F/410/B(U)-96 Revision Bi, Model No. MANON. In your application you requested that the NRC provide a recommendation to revalidate the Model No. MANON package for import and export use.
Based upon our review, the statements and representations contained in the application, and for the reasons stated in the enclosed safety evaluation report, we recommend revalidation of the French Certificate of Approval F/410/B(U)-96, for the Model No. MANON transport package.
The staff notes, however, that the application only provides calculations using acceleration factors in the SSG-26, Table IV.1, for international transport, but does not provide calculations to demonstrate that the package meets the tie down system design requirements for U.S.
transport in Table IV.2. Table IV.2 requires the use of higher recommended acceleration factors for U.S. transportation, which is consistent with the U.S. regulatory requirement Title 10 of the Code of Federal Regulations (10 CFR) Section 71.45(b)(1).
In accordance with Title 10 of the Code of Federal Regulations Part 2, Agency Rules of Practice and Procedure, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room (PDR) or from the Publicly Available Records component of the NRCs ADAMS. ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html. The PDR is open by appointment. To make an appointment to visit the PDR, please send an email to PDR.Resource@nrc.gov or call 1-800-397-4209 or 301-415-4737, between 8 a.m. and 4 p.m. eastern time (ET), Monday through Friday, except Federal holidays.
November 12, 2024
R. Boyle 2
If you have any questions regarding this matter, please contact me or Nishka Devaser of my staff at 301-415-5196.
Sincerely, Yoira Diaz-Sanabria, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-3094 EPID L-2023-DOT-0007
Enclosure:
Safety Evaluation Report Signed by Diaz-Sanabria, Yoira on 11/12/24
ML24304B048(pkg), ML24304B049(ltr), ML24304B050(encl)
OFFICE NMSS/DFM NMSS/DFM NMSS/DFM NMSS/DFM NAME NDevaser SFigueroa ASotomayorRivera GZhao DATE 11/1/24 11/1/24 11/1/24 11/4/24 OFFICE NMSS/DFM NMSS/DFM NMSS/DFM NMSS/DFM NAME JBorowsky JCarlson AThomlinson DJohnson DATE 11/5/24 11/5/24 11/8/24 11/8/24 OFFICE NMSS/DFM NMSS/DFM NMSS/DFM NMSS/DFM NAME TGovan TBoyce HRodriguez YDiaz-Sanabria DATE 11/12/24 11/12/24 11/12/24 11/12/24