Letter Sequence Response to RAI |
|---|
EPID:L-2023-LLA-0168, Louisiana Energy Services, LLC, Dba Urenco USA, License Amendment Request for Changes to License Conditions and Raise Enrichment Limit to Less than 1 O Weight Percent for Leu+ Production Systems (LAR-23-02) (Open) |
|
MONTHYEARML23334A1222023-11-30030 November 2023 Louisiana Energy Services, LLC, Dba Urenco USA, License Amendment Request for Changes to License Conditions and Raise Enrichment Limit to Less than 1 O Weight Percent for Leu+ Production Systems (LAR-23-02) Project stage: Request ML23334A1302023-11-30030 November 2023 Louisiana Energy Services, LLC, Environmental Information Project stage: Request ML24052A3852024-03-0101 March 2024 Acceptance for Review of Uusa License Amendment Request for Changes to License Conditions and Raise Enrichment Limit to Less than 10 Weight Percent for Leu+ Production Systems Project stage: Acceptance Review ML24187A1552024-07-12012 July 2024 Letter and Enclosure 1: Request for Additional Information Regarding Changes to License Conditions and Raise Enrichment Limit to Less than 10 Weight Percent for Low Enriched Uranium Plus Production Systems Project stage: RAI ML24214A3022024-08-0101 August 2024 Enclosure 2: Uusa Responses to Human Factors Engineering and Environmental RAIs Project stage: Request ML24214A3002024-08-0101 August 2024 Louisiana Energy Services, LLC, Dba Urenco USA, Responses to Requests for Additional Information Project stage: Response to RAI ML24240A0872024-08-27027 August 2024 Louisiana Energy Services, LLC - Semi-Annual Radiological Effluent Release Report for January 1, 2024 Through June 30, 2024 Project stage: Request ML24242A1982024-08-29029 August 2024 Louisiana Energy Services, LLC, Dba Urenco USA - Affidavit Project stage: Request ML24242A2002024-08-29029 August 2024 Louisiana Energy Services, LLC, Dba Urenco USA - Mark-up Pages to the Safety Analysis Report (LAR 24-01) Project stage: Request ML24242A2032024-08-29029 August 2024 Louisiana Energy Services, LLC, Dba Urenco USA - Environmental Information Project stage: Request ML24248A1892024-09-16016 September 2024 Cover Letter - Request for Additional Information Regarding Louisiana Energy Services, LLC License Amendment Request 23-02 - Changes to License Conditions and Raise Enrichment Limit to Less than 10 Weight Percent for Leu+ Production Systems Project stage: RAI ML24288A0092024-10-13013 October 2024 Louisiana Energy Services, LLC, Dba Urenco USA, Responses to Requests for Additional Information for LAR 23-02 (2nd Set) Project stage: Response to RAI ML24331A2602024-12-0202 December 2024 Environmental Assessment for Proposed License Amendment to Allow Urenco USA to Enrich Uranium to Less than 10 Weight Percent U-235, Lea County, New Mexico Project stage: Other ML24318C2412024-12-11011 December 2024 Cover Letter - Safety Evaluation Report for Uusa Request for Less than 10 Weight Percent Uranium 235 Project stage: Approval ML24318C2432024-12-11011 December 2024 Enclosure 3 - LES Amendment 105 for Uusa Request for Less than 10 Weight Percent Uranium 235 (Public) Project stage: Other ML24366A1222024-12-11011 December 2024 Enclosure 4 - Safety Evaluation Report for Uusa Request for Less than 10 Weight Percent Uranium 235 (Redacted) Project stage: Approval 2024-03-01
[Table View] |
Text
LES-24-126-NRC and Enclosure 2 transmitted by this letter contain Security Related Information. When both Enclosures are detached, this letter is decontrolled.
Security Related Information Withhold under 10 CFR 2.390 October 13, 2024 Attn: Document Control Desk Director, Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Louisiana Energy Services, LLC NRC Docket No. 70-3103
Subject:
Responses to Requests for Additional Information for LAR 23-02 (2nd set)
Reference:
- 1) IN-24-069-NRC, Request for Additional Information Regarding Louisiana Energy Services, LLC License Amendment Request 23 Changes to License Conditions and Raise Enrichment Limit to Less than 10 Weight Percent for Low Enriched Uranium Plus Production Systems (Enterprise Project Identification Number L-2023-LLA-0168)(ML24248A190, ML24248A191), dated 16 September 2024 In Reference 1, NRC provided the 2nd set of Requests for Additional Information (RAIs) for License Amendment Request (LAR) 23-02 regarding UUSA Nuclear Criticality Safety (NCS) and Integrated Safety Analysis (ISA) in order to complete their technical review. Enclosure 1 provides responses to questions asked regarding NCS. Enclosure 2 provides responses to questions asked regarding ISA. Enclosures 1 and 2 contain Security Related Information, as such, UUSA requests Enclosures 1 and 2 be withheld from public disclosure pursuant to 10 CFR 2.390(d)(1).
If you have any questions regarding these responses, you may contact Jim Freels, Licensing Consultant, at 575-394-6018.
Respectfully, Paul Lorskulsint Chief Nuclear Officer and Head of Compliance
Enclosures:
- 1) UUSA Responses to NCS RAIs
- 2) UUSA Responses to ISA RAIs
LES-24-126-NRC and Enclosure 2 transmitted by this letter contain Security Related Information. When both Enclosures are detached, this letter is decontrolled.
Security Related Information Withhold under 10 CFR 2.390 cc: via email Samantha Lav, Branch Chief Fuel Facility Licensing U.S. Nuclear Regulatory Commission Samantha.Lav@nrc.gov Johnathan Rowley, Senior Project Manager - UUSA U.S. Nuclear Regulatory Commission Johnathan.Rowley@nrc.gov