ML24242A324

From kanterella
Jump to navigation Jump to search
Duke Energy Carolinas - Catawba 2A EDG Regulatory Conference Meeting Summary - August 7, 2024
ML24242A324
Person / Time
Site: Catawba 
Issue date: 08/30/2024
From: Paul Carman
NRC/RGN-II/DRP/RPB1
To:
References
EA-24-049
Download: ML24242A324 (7)


Text

NRC REGULATORY CONFERENCE

SUMMARY

Licensee:

Duke Energy Carolinas, LLC Facility:

Catawba Nuclear Station License No.:

NPF-52 Docket No.:

05000414 Date of Conference: August 7, 2024 Meeting No.:

20240948 Enforcement Action: EA-24-049 On August 7, 2024, representatives of Duke Energy Carolinas, LLC (Duke Energy), Catawba Nuclear Station, met with U.S. Nuclear Regulatory Commission (NRC) personnel in the Region II office located in Atlanta, Georgia. Some NRC staff participated virtually via Microsoft Teams. The purpose of the regulatory conference was to discuss the apparent violation (AV) documented in NRC Inspection Report Number 05000414/2024090, dated June 24, 2024 (NRC's Agencywide Documents Access and Management System (ADAMS) Accession Number ML24166A010). The regulatory conference was held at the request of Duke Energy and was characterized as an NRC Observation public meeting. Public participation in the meeting was via teleconference and Microsoft Teams. The attendance list is provided as an enclosure to this summary.

NRC representatives described the intent of the meeting and summarized the preliminary White finding and associated AV. NRC staff also explained that no final decisions would be made during the meeting, and information provided during the meeting, and prior to the meeting, would be considered and assessed to make a final decision. NRC staff communicated their goal to complete an internal review, and communicate a final decision to Duke Energy and the public, by September 13, 2024.

The licensee and their representatives presented their response to the preliminary White finding and AV. The licensee provided acknowledgement of the AV, their assessment of the significance of the finding, a summary of the causes for the AV and their corrective actions. The licensee also provided new information and asserted that their updated evaluation and risk information supported a significance of Green, or very low safety significance. A copy of the licensees presentation and supplemental information is publicly available at ADAMS Accession Number ML24214A224.

At the close of the business portion of the meeting, members of the public were allowed to ask any relevant questions to NRC participants. There were no questions asked or comments made by members of the public. Following these actions, the meeting was adjourned.

In accordance with 10 CFR 2.390 of the NRCs Agency Rules of Practice and Procedure, a copy of this conference summary and enclosure will be made available electronically for public inspection in the NRC Public Document room or in ADAMS, accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.

Enclosure:

Attendance List cc w/ encl: Distribution via LISTSERV

ML24242A324 X

SUNSI Review X

Non-Sensitive

Sensitive X

Publicly Available

Non-Publicly Available OFFICE RII/DRP NAME P. Carman DATE 8/30/2024

1 Enclosure Attendance List NRC Regulatory Conference Duke Energy Carolinas, LLC (Duke) - Catawba Nuclear Station (CNS)

August 7, 2024 U.S. NRC Region II Conference Center Please note this list contains the best available data from the Teams meeting log.

Region II Office (In-person)

Microsoft Teams (audio/video)

Participant Affiliation Participant Affiliation Mark Miller NRC Dante Johnson NRC Mark Franke NRC Antonios Zoulis NRC Eric Stamm NRC David Rivard NRC Donna Jackson NRC Anny Wang NRC Paul Carman NRC Sarah Price NRC Christopher Even NRC Theodore Fanelli NRC Joylynn Quinones-Navarro NRC Mark Kowal NRC Shane Sandal NRC Andy Rosebrook NRC Joel Rivera Ortiz NRC Dan Bradley NRC Steven Capps Duke Nicole Flippin Duke Jonathan Huecker Duke Kevin Ellis Duke Scott Milton Duke Josh Stewart Duke Kyle Pursley Duke Jennifer Varnedoe Duke Amol Limaye MPR Ling-Yu Song MPR

2 Enclosure Microsoft Teams (audio/video)

Microsoft Teams (bridge -

last 4 digits Attendee Attendee Alejandro Alen Arias Goulet, Nicholas M.

Sanders, Jeff D 2680 Andrews, Sherry E Jeff Hardy Sharon1 5606 Arist Hu Jobin Binu Daniel Shawn Williams 5235 Bickley, Brandon John Pelchat Sims, Cody (Scott) 5535 Boyer, Robert P Justin Bouknight Susan E. Jenkins 9392 Browder, Justin Justin Donohoe Szews, Heather Davis 7965 Chamberlain, Amy Christine Kanipe Jr., Lee M Thomas Easum Chris Safouri Keion Henry Weakland, Scott C Clark1, John Langholz, John Weiser, Casey Bud Cox, Trey Linden, Allison Wilmers, Matthew J.

Craig XXXXX1 Luke XXXXX1 Wright, Kelly Crispulo L. Isiminger Marcus Riley Cummings, David A Melanie Checkle Daniel Ryan Michael Magyar Dave Gasperson Nelson, Matthew Lee Delza Parent Noonan, Kimberley M.

Dewhirst, Linda R.

Pittman, Jared M Edwin Lyman Reinaldo Rodriguez Ernestine Kuhr Rishel, Robert I Farish, Paul T Ritzman, Robin Fletcher II, Cecil Alexander Robert Mikouchi-Lopez Frank Young CR-CLT-Plaza-3769-TEAMS-(10)

Gordon Curran CRP-CNS-AdminBldg7720-VPConfRm-TEAMS-(12) 1 Full name not provided