Rachael Davis (She/Her/Hers)
Smith, Derek Audrey Klett Official RCI for Susquehanna"s Proposed Alternative 1RR06 Wednesday, August 21, 2024 9:25:00 AM Good morning, Derek, Attached is the official RCI (Request for Confirmation of Information) for Susquehannas Proposed Alternative, 1RR06. The requested response date is September 20, 2024, as we discussed. Please let Audrey Klett or me know if you have any questions.
Thank you, Rachael Davis She/Her/Hers Data Scientist & Project Manager U.S Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Operating Reactor Licensing
1 REQUEST FOR ADDITIONAL INFORMATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION SUSQUEHANNA 1 - VERBAL ALTERNATIVE REQUEST FOR IST INTERVAL EXTENSION SUSQUEHANNA NUCLEAR, LLC SUSQUEHANNA, UNIT 1 DOCKET NO. 05000387 ISSUE DATE: 08/21/2024
Background
On March 27, 2024 (ML24080A502), and March 28, 2024 (ML24080A395), NRC authorized, Alternative Requests RR01and RR02, respectively, for the Fifth 10-Year IST Program interval starting on June 1, 2024. The applicable code for both alternatives is the ASME OM Code, 2020 Edition. Per Alternative Request 1RR06 (to extend the fourth 10-year IST Interval), the start date of Alternative Requests RR01 and RR02 for the Fifth 10-Year IST interval would be changed to June 1, 2025.
Question 1 The NRC staff requests the licensee to confirm that with the extension of the fourth 10-year IST interval as proposed in Alternative Request 1RR06, the start date of Alternative Requests RR01 and RR02 for the fifth 10-year IST interval will be June 1, 2025.
OFFICE NRR/DORL/LPMB/PM NRR/DORL/LPL1/BC NRR/DORL/LPL1/PM NAME RDavis HGonzalez HGonzalez DATE 08/15/2024 08/15/2024 08/15/2024 OFFICE NRR/DEX/EMIB/BC NAME SBailey DATE 08/15/2024