Constellation~*

July 16, 2024 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Calvert Cliffs Nuclear Power Plant, Unit No. 1 Renewed Facility Operating License No. DPR-53 NRC Docket No. 50-317

Subject:

lnservice Inspection Report Larry D. Smith Manager-Regulatory Assurance Calvert Cliffs Nuclear Power Plan t 1650 Calvert Cliffs Parkway Lusby. MD 20657 667 313 6503 Office larry.sm1th2@constellat1on.com

Reference:

1.

American Society of Mechanical Engineers, Boiler & Pressure Vessel Code,Section XI, Article IWA-6000

2.

Relief Request authorized the use of paragraphs IWA-6220, IWA-6230, and Mandatory Appendix II of the 2019 Edition of the ASME BPV Code,Section XI (ML23114A252)

Pursuant to References 1 and 2, please find enclosed the Owner's Activity Report (Form OAR-1) for the Calvert Cliffs Nuclear Power Plant Unit 1 Spring 2024 refueling outage.

There are no regulatory commitments contained in this letter.

Should you have questions regarding this matter, please contact Mr. Larry D. Smith at (667) 313-6503.

Respectfully,

~t~

Larry D. Smith Manager - Regulatory Assurance LDS/aj

Enclosure:

( 1) 2024 Owner's Activity Report for CC 1 R27 cc:

(Without Enclosure)

NRC Project Manager, Calvert Cliffs NRC Regional Administrator, Region I NRC Resident Inspector, Calvert Cliffs S. Seaman, MD-DNR