Industry/NRC Materials Programs Technical Information Exchange Advanced Manufacturing Technologies Carolyn Fairbanks U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of New and Renewed Licenses Vessels and Internals Branch June 25, 2024
AMT Teams 2
Project Team
- Carolyn Fairbanks, NRR Technical Lead
- Eric Focht, RES Technical Lead
- Bob Davis, NRR
- Carol Nove, RES (NDE)
Technical Advisory Team
- Rob Tregoning, NRR Steering Oversight Committee
- Angie Buford, NRR (Chair)
Advanced Manufacturing Technologies
- Techniques and material processing methods
- Not traditionally used in the U.S.
nuclear industry
- Not formally standardized/codified by the nuclear industry
- AMTs can include new ways to fabricate or join components, surface treatments, or other processing techniques to provide a performance or operational benefit.
3
Examples of U.S. Applications installed under 10 CFR 50.59 4
Channel Fastener
- Browns Ferry Unit 2
- 316L stainless steel - LPBF
- Byron Unit 1
- 316L stainless steel - LPBF
- Non ASME B&PV Code class Credit: Westinghouse
NRC AMT Action Plan, Rev. 1 NRCs initial focus areas Laser powder bed fusion (LPBF)
Laser direct energy deposition (L-DED)
Cold spray (CS)
Electron beam welding (EBW)
Power metallurgyhot isostatic pressing (PM-HIP) 5
- Technical Preparedness
Technical Letter Reports (National Laboratories)
NRC Technical Assessments
- Regulatory Preparedness
Draft Guidelines Documents - technology specific
Draft Review Guidelines - generic
Implementation Using the 50.59 Process for AMTs Communications and Knowledge Management
Engagement with industry, codes & standards, research organizations, international
Staff development
- new reactor fuel technologies are addressed outside the AMT Action Plan
Action Plan Products - Technical Preparedness - https://www.nrc.gov/reactors/power/amts.html 6
LPBF ML20351A292 L-DED ML21301A077 Cold Spray ML21263A105 Final Guidance for Initial AMTs (potential future effort)
PM-HIP ML22164A437 EBW ML22143A927 Technical Letter Reports & Assessments LPBF ML21074A040 L-DED ML22143A951 Cold Spray ML22143A952 PM-HIP EBW Technology-Specific Draft Review Guidelines Implementation using 10 CFR 50.59 Process ML21155A043 Assessment of Regulatory Guidance ML20233A693 Draft Guidelines Document for AMTs ML21074A037 NDE Gap Analysis ML20349A012 Modeling Gap Analysis ML20269A301 ML20350B550 NRC Staff-developed Contractor-developed Legend Generic Guidelines
& Assessments
NRC Ongoing and User Need Request Activities 7
Technical Preparedness
- Assessment of additional technologies: Arc--DED and diode laser cladding
- Evaluation of long-term performance, including environmental effects (e.g., irradiation, corrosion)
Participation in ASME Code activities Communications and KM:
NRC NDE of AMT Technical Exchange: May 2023 NRC AMT Workshop: October 2023
UNR Tasks -
Technical Preparedness
- Additional Technical Assessments
- Arc Directed Energy Deposition
- Mock-ups and evaluation
- Data and Modeling for Qualification
- In-process monitoring
- Digital data characterization
- Materials Performance of AMT Components 8
Questions?