INFORMATION REPORT APRIL 17, 2024 SECY-24-0033 FOR:

The Commissioners FROM:

Jody C. Martin Acting Associate Director for Operations Office of the Executive Director for Operations

SUBJECT:

WEEKLY INFORMATION REPORT - WEEK ENDING APRIL 12, 2024 CONTENTS Enclosure Office of the Chief Human Capital Officer A

Office of the Chief Information Officer B

Office of Nuclear Reactor Regulation C

Office of Nuclear Material Safety and Safeguards D

Office of the Secretary E

Acting Associate Director for Operations, OEDO CONTACT: John R. Jolicoeur, OEDO 301-415-1642 Signed by Martin, Jody on 04/17/24

ML24108A032 OFFICE OEDO OEDO/ADO NAME JJolicoeur JMartin DATE 04/17/2024 04/17/2024

Office of the Chief Human Capital Officer Items of Interest Week Ending April 12, 2024 ARRIVALS NONE RETIREMENTS NONE DEPARTURES LISKA, STEPHANIE L.

REACTOR INSPECTOR R-III APRIL 17, 2024 ENCLOSURE A

Office of the Chief Information Officer Items of Interest Week Ending April 12, 2024 Freedom of Information Act (FOIA) and Privacy Act (PA) Requests and Appeals Received During the Period of April 8 - April 12, as submitted by requester Tracking Number Requesters Name Requesters Organization Request Description Received Date FOIA-2024-000142

Weir, Vivienne Partners Environmental Consulting Partners Environmental Consulting is looking into the property located at 6801 Cochran Road in Solon, Ohio 44139. This facility is listed in several databases including MLTS (license #

34-06558-05) and NY MANIFEST (EPA ID: OHD070762596) but no additional information is currently reported. Do you have any records of these incidents or anything else of environmental impact?

04/09/2024 FOIA-2024-0001441

Rodgers, Jimmy
Summers, Rufolo &

Rodgers, P.C.

NRC Form 4-Cumulative Occupational Dose History for named individual 04/11/2024 APRIL 17, 2024 ENCLOSURE B 1 FOIA-2024-000143 was a duplicate of FOIA-2024-000144.

Office of Nuclear Reactor Regulation Items of Interest Week Ending April 12, 2024 Cooper Nuclear Station Emergency License Amendment On April 5, 2024, the staff issued an Emergency License Amendment for Cooper Nuclear Station (Agencywide Documents Access and Management System (ADAMS) Accession No. ML24096A120). The plants current design configuration of the Turbine Stop Valve position switches, that input to the Reactor Protection System, does not meet channel independence criteria. The amendment provides a temporary footnote that allows the licensee to not enter the associated Technical Specification Limited Condition for Operation until the channel condition is resolved no later than startup from the next refueling outage scheduled for Fall 2024. This Emergency License Amendment is in response to a Notice of Enforcement Discretion granted on March 29, 2024.

U.S. Nuclear Regulatory Commission (NRC) Issued Amendments for McGuire Nuclear Station to Adopt Technical Specifications Task Force (TSTF) Traveler TSTF-505 and to Implement 10 CFR 50.69 On March 26 and April 8, 2024, respectively, the U.S. Nuclear Regulatory Commission (NRC) issued amendments for McGuire Nuclear Station to adopt Technical Specifications Task Force (TSTF) Traveler TSTF-505 for risk-informed completion times (CTs) of Technical Specifications (TS) limiting condition for operation (LCOs) (ML24031A540), and to implement 10 CFR 50.69 for risk-informed categorization and treatment of structures, systems, and components (SSCs)

(ML24052A306). The TSTF-505 amendment adds substantial flexibility by providing for up to a 30-day backstop for TS LCO CTs. The 10 CFR 50.69 amendment allows the implementation of a process for categorizing and special treatment of SSCs using risk. The advancement of the licensees Probabilistic Risk Assessment to support these initiatives will add substantial opportunities to enhance the use of risk in licensee programs and operations. Including the McGuire approvals, the NRC has issued 32 TSTF-505 amendments and 35 10 CFR 50.69 amendments for nuclear power plants.

NRC Accepted an Initial License Renewal Application (LRA) from Constellation Energy Group Requesting an Additional 20 Years for the Renewed Operating License of Clinton Power Station On April 12, 2024, the staff accepted an initial license renewal application (LRA) from Constellation Energy Group requesting an additional 20 years for the renewed operating license of Clinton Power Station (CPS), Unit 1. If approved for initial license renewal, CPS will extend its license to April 17, 2047. The review is scheduled for 20 months with an estimated total of 17,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br />.

APRIL 17, 2024 ENCLOSURE C

Office of Nuclear Material Safety and Safeguards Items of Interest Week Ending April 12, 2024 List of Approved Spent Fuel Storage Casks: FuelSolutions' Spent Fuel Management System, Certificate of Compliance No. 1026, Renewal of Initial Certificate and Amendment Nos. 1 Through 4 On April 8, 2024, the acting Executive Director of Operations signed a direct final rule (Agencywide Documents Access and Management System (ADAMS) Accession No. ML24019A054) and a companion proposed rule (ML24019A052) to renew the FuelSolutions' Spent Fuel Management System initial certificate of compliance and Amendment Nos. 1 through 4 for 40 years. The renewal would revise the certificates conditions and technical specifications to address aging management activities related to the structures, systems, and components important to safety of the dry storage system to ensure that these will maintain their intended functions during the period of extended storage operations. The direct final rule and companion proposed rule will be forwarded to the Office of the Federal Register on April 16, 2024, for publication on or about April 22, 2024.

List of Approved Spent Fuel Storage Casks: NAC Universal Multipurpose Canister System, Certificate of Compliance No. 1015, Renewal of Initial Certificate and Amendment Nos. 1 through 9 On April 9, 2024, the acting Executive Director of Operations signed a direct final rule (ML24036A064) and a companion proposed rule (ML24036A059) to renew the NAC Universal Multipurpose Canister System initial certificate of compliance and Amendment Nos. 1 through 9 for 40 years. The renewal changes the certificates conditions and technical specifications to address aging management activities related to the structures, systems, and components important to safety of the dry storage system to ensure that these will maintain their intended functions during the period of extended storage operations. The direct final rule and companion proposed rule will be forwarded to the Office of the Federal Register on April 17, 2024, for publication on or about April 23, 2024.

APRIL 17, 2024 ENCLOSURE D

Office of the Secretary Items of Interest Week Ending April 12, 2024 Document Released to Public Date of Document Subject Decision Documents 1.

Staff Requirements Memorandum SECY-16-0033 04/11/2024 Final Draft Rulemaking - 10 CFR 50.46c:

Emergency Core Cooling Systems Performance During Loss-of-Coolant Accidents Information 1.

SECY-24-0026 03/28/2024 Achieving Timely Completion of License Renewal Safety and Environmental Reviews (License Renewal Roadmap) 2.

SECY-24-0031 04/11/2024 Weekly Information Report Week Ending April 5, 2024 Memoranda 1.

Staff Requirements Memorandum M240409A 04/09/2024 Affirmation Session - SECY-24-0010: Motion to Quash Subpoena in Missouri State Emergency Management Agency Investigation Commission Correspondence 1.

Letter to the Honorable Mike Johnson, et al., submits the NRC's Fiscal Year 2023 Annual Report on the Notification and Federal Employees Antidiscrimination and Retaliation Act of 2002 (No FEAR Act) 2.

Letter to the Honorable Cathy McMorris Rodgers, et al., submits the February 2024 monthly status report on the NRC activities and use of unobligated carryover funds appropriated from the Nuclear Waste Fund Federal Register Notices Issued 1.

715th Meeting of the Advisory Committee on Reactor Safeguards (ACRS)

APRIL 17, 2024 ENCLOSURE E