Letter Sequence Approval |
|---|
|
|
MONTHYEARML20350B8342020-12-14014 December 2020 Submittal of Topical Report WCAP-18446-P / WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Request PMNS20210084, Closed Meeting to Discuss Acceptance Review Findings for the Westinghouse Electric Company WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Topical Re2021-01-22022 January 2021 Closed Meeting to Discuss Acceptance Review Findings for the Westinghouse Electric Company WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Topical Report Project stage: Acceptance Review ML21050A2502021-02-19019 February 2021 Closed Call to Discuss Supplemental Information to the Westinghouse Electric Company Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Request ML21048A0662021-02-24024 February 2021 Summary of the Closed Meeting to Discuss Completeness Review Findings for the Westinghouse Topical Report WCAP-18446-P/WCAP-18446-NP, Rev.0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engine Fuel Designs Project stage: Meeting ML21053A3842021-03-0101 March 2021 NRC 897 Proprietary Withholding Determination Form Westinghouse Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Other ML21053A4122021-03-0101 March 2021 NRC 898 Completeness Determination Form Westinghouse Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Other ML21053A2352021-03-0202 March 2021 Email Completeness Form and Proprietary Information Withholding Determination Form Westinghouse Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel De Project stage: Other ML21064A2272021-03-0909 March 2021 March 5, 2021, Summary of Closed Call to Discuss Supplemental Information to Westinghouse Electric Company Topical Report WCAP-18446-P/WCAP-18446-NP, Rev. 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Project stage: Other PMNS20210340, Forthcoming April 8-9, 2021, Closed Regulatory Audit of the Westinghouse Electric Company Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Desi2021-03-23023 March 2021 Forthcoming April 8-9, 2021, Closed Regulatory Audit of the Westinghouse Electric Company Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Request ML21083A1212021-03-30030 March 2021 Cover Letter with Enclosure April 8-9, 2021, Regulatory Audit Plan for the Westinghouse Electric Company Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineerin Project stage: Other ML21153A0682021-06-0707 June 2021 NRC 897 WCAP-18446-P Supplement Topical Report Withholding Determination Form Project stage: Other ML21344A0762021-12-15015 December 2021 Email Requests for Additional Information for the Westinghouse Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: RAI ML22262A3232022-09-21021 September 2022 Email Second Round of Requests for Additional Information for the Westinghouse Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: RAI ML23164A2012023-06-29029 June 2023 NRC 897 Withholding Determination Forms Set 2 Round 2 RAI Responses WCAP-18446-P/WCAP-18446-NP, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: RAI ML23164A1012023-06-30030 June 2023 NRC 897 Withholding Determination Forms Set 1 Round 2 RAI Responses WCAP-18446-P/WCAP-18446-NP, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: RAI ML23240A7302023-08-28028 August 2023 Transmittal Email Updated Schedule WCAP-18446-P/WCAP-18446-NP, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Other ML23278A0582024-02-26026 February 2024 Cover Letter for the U.S. NRC Draft Safety Evaluation for Westinghouse Electric Company Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Draft Approval PMNS20240348, Closed Call Between USNRC and Westinghouse Electric Company for the Review of Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs2024-03-0707 March 2024 Closed Call Between USNRC and Westinghouse Electric Company for the Review of Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Request ML24096A0402024-04-12012 April 2024 Summary of Closed Call U.S. Nuclear Regulatory Commission Review of Westinghouse Electric Company Topical Report WCAP-18446-P_NP, Rev 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Approval ML24106A3012024-04-12012 April 2024 Comments and Proprietary Markings on the Draft Safety Evaluation for Westinghouse Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Request ML24123A2092024-05-13013 May 2024 Withholding Determination NRC Form 897 Westinghouse Slides for ACRS Full Committee Review of WCAP-18446-P Np, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Approval ML24123A1862024-05-13013 May 2024 Withholding Determination NRC Form 897 Westinghouse Slides for ACRS Subcommittee Review of WCAP-18446-P Np, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Approval ML24152A2972024-05-29029 May 2024 Amended Comments and Proprietary Markings on the Draft Safety Evaluation for Westinghouse Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Request ML24107B1592024-06-26026 June 2024 Cover Letter for the U.S. NRC Final Safety Evaluation for Westinghouse Electric Company Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Approval ML24176A2582024-06-26026 June 2024 Non-Proprietary Enclosure 1 for U.S. NRC Final Safety Evaluation for Westinghouse Electric Company Topical Report WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Project stage: Approval ML24227A5912024-08-0909 August 2024 Submittal of WCAP-18446-P-A/WCAP-18446-NP-A, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs (Proprietary/Nonproprietary) Project stage: Request ML24276A0922024-10-0909 October 2024 U.S. NRC Verification for Westinghouse Electric Company Topical Report WCAP-18446-P-A/WCAP-18446-NP-A, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs Project stage: Other 2022-09-21
[Table View] |
Text
OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION June 26, 2024 Camille Zozula Manager, Infrastructure & Facilities Licensing Westinghouse Electric Company 1000 Westinghouse Drive, Building 1, Suite 165 Cranberry Township PA 16066
SUBJECT:
FINAL SAFETY EVALUATION FOR WESTINGHOUSE ELECTRIC COMPANY TOPICAL REPORT WCAP-18446-P/WCAP-18446-NP, REVISION 0, INCREMENTAL EXTENSION OF BURNUP LIMIT FOR WESTINGHOUSE AND COMBUSTION ENGINEERING FUEL DESIGNS (EPID: L-2020-TOP-0064)
Dear Camille Zozula,
By letter dated December 14, 2020, Westinghouse Electric Company (Westinghouse) submitted to the U.S. Nuclear Regulatory Commission (NRC) Westinghouse Topical Report (TR)
WCAP-18446-P/WCAP-18446-NP, Revision 0, Incremental Extension of Burnup Limit for Westinghouse and Combustion Engineering Fuel Designs. By the letter dated February 26, 2024, the U.S. Nuclear Regulatory Commission (NRC) staff issued its draft safety evaluation (SE) (Agencywide Documents Access and Management System Accession No. ML23278A058).
The NRC staff has found the TR acceptable for referencing in licensing applications for nuclear power plants to the extent specified and under the limitations delineated in the TR and in the NRC final SE. The final SE defines the basis for our acceptance of the TR.
Our acceptance applies only to material provided in the subject TR. We do not intend to repeat our review of the accepted material described in the TR. When the TR appears as a reference in license applications, our review will ensure that the material presented applies to the specific plant involved. License amendment requests that deviate from this TR will be subject to a plant-specific review in accordance with applicable review standards.
NOTICE: Enclosure 2 to this letter contains Proprietary Information. Upon separation from Enclosure 2, this letter is DECONTROLLED.
OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION In accordance with the guidance provided on the NRC website, we request that Westinghouse publish accepted versions of the proprietary and non-proprietary TR within three months of receipt of the date of this letter. The accepted proprietary version shall incorporate this letter and the proprietary final SE (Enclosure 2), and the accepted non-proprietary version shall incorporate this letter and the non-proprietary final SE (Enclosure 1) after the title page. Also, the accepted versions must contain historical review information, including NRC requests for additional information (RAIs) and your responses after the title page. The accepted version shall include an -A (designating accepted) following the TR identification symbol.
As an alternative to including the RAIs and RAI responses behind the title page, if changes to the TRs were provided to the NRC staff to support the resolution of RAI responses, and the NRC staff reviewed and approved those changes as described in the RAI responses, there are two ways that the accepted version can capture the RAIs:
- 1. The RAIs and RAI responses can be included as an Appendix to the accepted version.
- 2. The RAIs and RAI responses can be captured in the form of a table (inserted after the final SE) which summarizes the changes as shown in the approved version of the TR. The table should reference the specific RAIs and RAI responses which resulted in any changes, as shown in the accepted version of the TR.
If future changes to the NRCs regulatory requirements affect the acceptability of this TR, Westinghouse will be expected to revise the TR appropriately. Licensees referencing this TR would be expected to justify its continued applicability or evaluate their plant using the revised TR.
If you have any questions, please contact the Project Manager for the review, Ekaterina Lenning at 301-415-3151 or via electronic mail at Ekaterina.Lenning@nrc.gov.
Sincerely,
/RA/
Gerond A. George, Chief Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No.: 99902038
Enclosures:
- 1. Final SE (Non-Proprietary)
- 2. Final SE (Proprietary)
ML24107B157 (Package)
ML24107B159 (Cover Letter)
ML24176A258 (Non-Proprietary Final SE Enclosure 1)
ML24107B158 (Proprietary Final SE Enclosure 2)
NCP-2023-006: ML24053A348 OFFICE NRR/DORL/LLPB/
PM NRR/DORL/LLPB/
LA NRR/DSS/SFNB NRR/DSS/SFNB NRR/DSS/SFNB/
BC NAME ELenning DHarrison JLehning Nonconcur KHeller Nonconcur SKrepel DATE 5/15/2024 5/22/2024 12/06/2023 12/06/2023 5/23/2024 OFFICE OGC - NLO NRR/DORL/LLPB/
BC NAME DRoth GGeorge OFFICE 6/20/2024 6/26/2024