August 1, 2024 Technical Specifications Task Force 11921 Rockville Pike, Suite 100 Rockville, MD 20852

SUBJECT:

DRAFT SAFETY EVALUATION OF TECHNICAL SPECIFICATIONS TASK FORCE TRAVELER TSTF-576, REVISION 3, REVISE SAFETY/RELIEF VALVE REQUIREMENTS (EPID L--2019-PMP-0207)

Dear Members of the Technical Specifications Task Force:

By letter dated September 13, 2023 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML23256A266), the Technical Specifications Task Force (TSTF) submitted to the U.S. Nuclear Regulatory Commission (NRC) for review and approval Traveler TSTF-576, Revision 3, Revise Safety/Relief Valve Requirements (TSTF-576). The NRC staffs draft safety evaluation (SE) of the traveler is enclosed. A draft model SE will be prepared later. Enclosure 2 is a supplement to the staffs SE. The supplement additional background information related to the traveler, but immaterial to the staffs safety findings or wasnt within scope of the SE.

Thirty calendar days are provided for you to comment on any factual errors or clarity concerns contained in the enclosed draft SE. The final SE will be issued after making any necessary changes. To facilitate the NRC staff's review of your comments, please provide a marked-up copy of the draft SE showing proposed changes and provide a summary table of the proposed changes.

If you have any questions, please contact Michelle Honcharik at 301-415-1774 or via e-mail at Michelle.Honcharik@nrc.gov.

Sincerely, Shivani N. Mehta, Chief Technical Specifications Branch Division of Safety Systems Office of Nuclear Reactor Regulation Project No. 753

Enclosures:

1) Draft Traveler SE and 2) Supplement to SE cc: See next page

Technical Specifications Task Force Project No. 753 cc:

Technical Specifications Task Force c/o EXCEL Services Corporation 11921 Rockville Pike, Suite 100 Rockville, MD 20852 Attention: Brian D. Mann E-mail: brian.mann@excelservices.com Jordan L. Vaughan Duke Energy 525 S. Tryon St.

B0009-037-B Charlotte, NC 28202 Email: jordan.vaughan@duke-energy.com Shane Jurek 2818 Provin Oaks Ct NE Grand Rapids, MI 49525 Email: Shane.Jurek@pseg.com Drew Richards STP Nuclear Operating Company 12090 FM 521 Mail Code: N5016 Wadsworth, TX 77483 Email: amrichards@stpegs.com Kevin Lueshen Constellation Energy Generation 4300 Winfield Road Warrenville IL 60555 Email: kevin.lueshen@constellation.com Wesley Sparkman Southern Nuclear Operating Company 3535 Colonnade Parkway / Bin N-274-EC Birmingham, AL 35243 Email: wasparkm@southernco.com

Technical Specifications Task Force

SUBJECT:

DRAFT SAFETY EVALUATION OF TECHNICAL SPECIFICATIONS TASK FORCE TRAVELER TSTF-576, REVISION 3, REVISE SAFETY/RELIEF VALVE REQUIREMENTS (EPID L--2019-PMP-0207) DATED AUGUST 1, 2024 DISTRIBUTION:

PUBLIC RidsNrrOd RidsNrrDss RidsOgcMailCenter RidsOpaMail RidsACRS_MailCTR RidsNrrDssStsb RidsNrrDssSnsb RidsNrrzDssSfnb RKuntz, NRR/DORL/LPL3 Mhoncharik, NRR/DSS/STSB SSmith, NRR/DSS/STSB RBeaton, NRR/DSS/SNSB NHansing, NRR/DEX/EMIB BParks, NRR/DSS/SFNB RElliott, NRR/DSS/STSB JKim, NRR/DORL/LPL1 ADAMS Accession Number: ML24106A276 Package: ML24106A286 Draft traveler SE: ML24053A102 SE Supplement: ML24204A271 NCP-2024-002: ML24096B710

  • concurred via e-mail NRR-106 OFFICE NRR/DEX/EMIB/BC*

NRR/DSS/SNSB*

NRR/DSS/SFNB/BC*

NRR/DORL/LPL1/BC*

NAME SBailey RBeaton (Nonconcur)

SKrepel HGonzález DATE 08/01/2024 03/04/2024 07/24/2024 07/26/2024 OFFICE OGC/NLO NRR/DSS/STSB/PM*

NRR/DSS/STSB/BC*