Meeting Slides - Preapplication with Constellation on Planned Fleet Alternative Request to Adopt OMN-2
ML24100A767
Person / Time
Site: Calvert Cliffs, Dresden, Peach Bottom, Nine Mile Point, Byron, Braidwood, Limerick, Ginna, Clinton, Quad Cities, FitzPatrick, LaSalle  
(NPF-072, NPF-077, NPF-037, NPF-066, DPR-053, DPR-069, NPF-062, DPR-019, DPR-025, DPR-059, NPF-011, NPF-018, NPF-039, NPF-085, DPR-063, NPF-069, DPR-044, DPR-056, DPR-029, DPR-030, DPR-018)
Issue date: 04/11/2024
From: Robert Kuntz
Constellation Energy Generation
To: Rhoades D
Plant Licensing Branch III
Wall, SP
References
Download: ML24100A767 (1)


Text

NRC Pre-Submittal Meeting ConstellationFleetInservice TestingProgramReliefRequest toUtilizeOMN32

  • Relief Request
  • Code Case
  • 10 CFR and ASME References
  • Submittal and Precedent
  • Summary
  • The relief request is for an alternative pursuant to 10 CFR 50.55a (z),

Alternatives to codes and standards requirements, to utilize ASME Code Case OMN-32, Alternative Requirements for Range and Accuracy of Pressure, Flow, and Differential Pressure Instruments Used in Pump Tests.

  • Code Case OMN-32 provides alternative testing instrument accuracy and range requirements for flow, pressure, and differential pressure instruments used for Group A, Group B, Comprehensive, and Preservice pump tests

-Instruments used for speed and vibration testing would continue to meet the existing instrument accuracy and range requirements in ASME OM Code.

Program at each of Constellations 21 Nuclear Units.

  • Use of Code Case OMN-32 would eliminate the need to install temporary instruments reducing dose and person-hours.

RELIEF REQUEST 2

l NRC Pre-submittal Meeting for RR to utilize OMN-32

CodeCaseOMN32Alternative CurrentRequirement ASMECode Section Theanalogordigitalinstrument(s)shallbe calibratedwithinthelimitsspecifiedinTable1 fortherespectivetestquantity.Foran instrumentloop,therequiredaccuracyis instrumentloopaccuracyasdefinedinISTA 2000.

InstrumentaccuracyshallbewithinthelimitsofTableISTB35101.Ifa parameterisdeterminedbyanalyticalmethodsinsteadof measurement,thenthedeterminationshallmeettheparameter accuracyrequirementofTableISTB35101(e.g.,flowrate determinationshallbeaccuratetowithin+/-2%ofactual).Forindividual analoginstruments,therequiredaccuracyispercentoffullscale.For digitalinstruments,therequiredaccuracyisoverthecalibratedrange.

Foracombinationofinstruments,therequiredaccuracyisloop accuracy ISTB3510(a),

Accuracy Theanalogordigitalinstrument(s)shallbe designedandcalibratedintherangeforuseat theexpectedreading(e.g.,referencevalue)to bemeasuredorrecordedduringthetest.

(1) Thefullscalerangeofeachanaloginstrumentshallbenotgreater thanthreetimesthereferencevalue.

(2) Digitalinstrumentsshallbeselectedsuchthatthereferencevalue doesnotexceed90%ofthecalibratedrangeoftheinstrument.

ISTB3510(b),

Range CodeCaseOMN32Alternative CurrentRequirement Comprehensiveand PreserviceTests,%

GroupAandGroupB Tests,%

Comprehensiveand PreserviceTests,%

GroupAandGroupBTests, Quantity

+/-11/2

+/-6

+/-1/2

+/-2 Pressure

+/-6

+/-6

+/-2

+/-2 FlowRate

+/-11/2

+/-6

+/-1/2

+/-2 Differentialpressure l NRC Pre-submittal Meeting for RR to utilize OMN-32

  • Constellation has reviewed the following applicable provisions of 10 CFR 50.55a and the ASME Code:

-10 CFR 50.55a(b)(3), Conditions on ASME OM Code

-10 CFR 50.55a(b)(6), Conditions on ASME OM Code Cases

-10 CFR 50.55a(f)(4), Inservice testing standards requirement for operating plants

-10 CFR 50.55a(f)(5), Requirements for updating IST programs

-ASME OM-2004, with 2006 Addenda, Section ISTB 3510, General

-ASME OM-2012, no Addenda, Section ISTB 3510, General

-ASME OM-2017, no Addenda, Section ISTB 3510, General 10 CFR AND ASME REFERENCES 4

l NRC Pre-submittal Meeting for RR to utilize OMN-32

  • Constellation is targeting submittal by the end of April 2024 with a standard one-year approval period.
  • Constellations submittal will incorporate two comments provided by the NRC during the review and subsequent approval of Code Case OMN-32.

-The title of the proposed Requirements and the corresponding Table were modified to state, Required Instrument Accuracy and Range.

-The use of analytical methods may be used provided the parameter determination meets the required OMN-32 accuracy.

  • No deviations from OMN-32 are being proposed.

PRECEDENT/SUBMITTAL 5

l NRC Pre-submittal Meeting for RR to utilize OMN-32

  • Code Case OMN-32 provides alternative testing instrument accuracy and range requirements for flow, pressure, and differential pressure instruments.
  • Constellation is targeting submittal by the end of April 2024; submittal will include each of Constellations 21 Nuclear Units.
  • Constellations submittal will be the first in the industry for a relief request to utilize ASME Code Case OMN-32.
  • The submittal will incorporate two comments provided by the NRC during the review and subsequent approval of Code Case OMN-32.
  • No deviations from the Code Case are being proposed.

SUMMARY

/KEY TAKEAWAYS 6

l NRC Pre-submittal Meeting for RR to utilize OMN-32

QUESTIONS?

7 lNRCPresubmittalMeetingforRRtoutilizeOMN32