Atachment 2 to ULNRC-06861 Page 1 of 3 ATTACHMENT 2 WESTINGHOUSE AND FRAMATOME ECCS EVALUATION MODEL MARGIN ASSESSMENTS
Atachment 2 to ULNRC-06861 Page 2 of 3 WESTINGHOUSE LARGE BREAK LOCA
SUMMARY
A.
ANALYSIS OF RECORD (AOR)
PCT = 1939°F B.
PRIOR ECCS MODEL ASSESSMENTS
+ 58°F C.
CURRENT LOCA MODEL ASSESSMENTS -
+ 0°F March 2024 LICENSING BASIS PCT + MARGIN ALLOCATIONS 1997°F ABSOLUTE MAGNITUDE OF MARGIN ALLOCATIONS 58°F SINCE LAST ANALYSIS OF RECORD OR LBLOCA 30-DAY REPORT FRAMATOME REALISTIC LARGE BREAK LOCA
SUMMARY
A.
ANALYSIS OF RECORD (AOR)
PCT = 1561°F B.
PRIOR ECCS MODEL ASSESSMENTS
+ 0°F C.
CURRENT LOCA MODEL ASSESSMENTS -
+ 0°F March 2024 LICENSING BASIS PCT + MARGIN ALLOCATIONS 1561°F ABSOLUTE MAGNITUDE OF MARGIN ALLOCATIONS 0°F SINCE LAST ANALYSIS OF RECORD OR RLBLOCA 30-DAY REPORT
Atachment 2 to ULNRC-06861 Page 3 of 3 WESTINGHOUSE SMALL BREAK LOCA
SUMMARY
A.
ANALYSIS OF RECORD (AOR)
PCT = 1043°F B.
PRIOR ECCS MODEL ASSESSMENTS
+ 0°F C.
CURRENT ECCS MODEL ASSESSMENTS -
+ 0ºF March 2024 LICENSING BASIS PCT + MARGIN ALLOCATIONS 1043°F ABSOLUTE MAGNITUDE OF MARGIN ALLOCATIONS 0°F SINCE LAST ANALYSIS OF RECORD OR SBLOCA 30-DAY REPORT FRAMATOME SMALL BREAK LOCA
SUMMARY
A.
ANALYSIS OF RECORD (AOR)
PCT = 1618°F B.
PRIOR ECCS MODEL ASSESSMENTS
+ 0°F C.
CURRENT ECCS MODEL ASSESSMENTS -
+ 0ºF March 2024 LICENSING BASIS PCT + MARGIN ALLOCATIONS 1618°F ABSOLUTE MAGNITUDE OF MARGIN ALLOCATIONS 0°F SINCE LAST ANALYSIS OF RECORD OR SBLOCA 30-DAY REPORT