ML24061A272
| ML24061A272 | |
| Person / Time | |
|---|---|
| Site: | Erwin (SNM-0124) |
| Issue date: | 04/18/2024 |
| From: | Lav S NRC/NMSS/DFM/FFLB |
| To: | Nuclear Fuel Services |
| Shared Package | |
| ML24061A271 | List: |
| References | |
| EPID L-2023-SPR-0014 | |
| Download: ML24061A272 (1) | |
Text
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION NRC FORM 374 U.S. NUCLEAR REGULATORY COMMISSION Page 1 of 11 MATERIALS LICENSE Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10 of the Code of Federal Regulations, Chapter I, Parts 30, 31, 32, 33, 34, 35, 36, 39, 40, and 70, and in reliance on statements and representations heretofore made by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, source, and special nuclear material designated below; to use such material for the purpose(s) and at the place(s) designated below; to deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is subject to all applicable rules, regulations, and orders of the U.S. Nuclear Regulatory Commission now or hereafter in effect and to any conditions specified below.
Licensee
- 1. Nuclear Fuel Services, Inc.
- 3. License Number: SNM-124, Amendment 21
- 2. 1205 Banner Hill Road Erwin, TN 37650-9718
- 4. Expiration Date: August 31, 2037
- 5. Docket Number: 70-143 Reference Number:
- 6. Byproduct Source, and/or
- 7. Chemical and/or Physical
- 8. Maximum amount that Licensee Special Nuclear Material Form May Possess at Any One Time Under This License A. Uranium enriched up to A.
As described in A. See Sensitive Conditions 100 weight percent in the Appendix 1B to U235 isotope which may the license application contain up to an average of 10-6 grams plutonium per gram of uranium, 0.25 millicuries of fission products per gram of uranium, and 1.5 x 10-5 grams transuranic materials (including plutonium) per gram of uranium, as contaminants B. Uranium enriched up B.1 Any form, but limited B.1 See Sensitive Conditions to 100 weight percent in to residual the U233 isotope contamination from previous operations This license contains SENSITIVE SECURITY-RELATED INFORMATION.
Upon removal of the Sensitive Conditions on Page 11, this license is DECONTROLLED.
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION Page 2 of 11 License Number SNM-124 MATERIALS LICENSE SUPPLEMENTARY SHEET Docket or Reference Number 70-143 Amendment 21 B.2 Any form, as received B.2 See Sensitive Conditions for analysis or for input into development studies C.
Plutonium C.1 As counting and C.1 10 millicuries calibration standards C.2 As residual C.2 As described in the contamination and license application holdup from previous operations C.3 Any form, as received C.3 See Sensitive Conditions for analysis or for input into development studies C.4 Any form, as waste C.4 See Sensitive Conditions resulting from decontamination and volume reduction of equipment received from other organizations D.
Transuranic Isotopes D.
As waste resulting D.
See Sensitive Conditions from processing enriched uranium E.
Fission Products E.
As waste resulting E.
See Sensitive Conditions from processing enriched uranium
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION Page 3 of 11 License Number SNM-124 MATERIALS LICENSE SUPPLEMENTARY SHEET Docket or Reference Number 70-143 Amendment 21 9.
Authorized place of use: The licensee's existing facilities in Unicoi County, Tennessee, as described in the referenced application.
10.
This license shall be deemed to contain two Sections: Safety Conditions and Safeguards Conditions.
These sections are part of the license, and the licensee is subject to compliance with all listed conditions in each section.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION Date: see digital signature By: _________________________________
Samantha C. Lav, Chief Fuel Facility Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Signed by Lav, Samantha on 04/18/24
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION Page 4 of 11 License Number SNM-124 MATERIALS LICENSE SUPPLEMENTARY SHEET Docket or Reference Number 70-143 Amendment 21 SAFETY CONDITIONS S-1 For use in accordance with the statements, representations, and conditions in the application submitted on the following dates, or as revised pursuant to Condition S-2 below:
June 30, 2009, and supplements dated July 2, August 18, August 28, and September 18, 2009; February 26, August 12, August 16, and September 23, 2010; April 13, May 13, May 27, June 24, July 28, August 1, August 5, September 9, September 27, September 30, and November 21, 2011; February 7, March 21, May 14, and October 10, 2012; January 18, 2013; June 20, September 4, September 9, and October 24, 2014; October 22, 2015; January 7, March 15, March 22, July 19, and December 15, 2016; June 16 and December 6, 2017; December 19, 2018; March 8 and October 2, 2019; November 18, 2021; October 4, 2022; and April 19, 2023.
S-2 NFS may make changes to the License Application that does not reduce the effectiveness of the License Application, without prior U.S. Nuclear Regulatory Commission (NRC) approval, if the change meets the following provisions:
(a)
The change does not decrease the level of effectiveness of the design basis as described in the License Application; (b)
The change does not result in a departure from the methods of evaluation described in the License Application used in establishing the design basis; (c)
The change does not result in a degradation of safety; (d)
The change does not affect compliance with applicable regulatory requirements; (e)
The change does not conflict with an existing license condition; and (f)
Within 6 months after each change is made, the licensee shall submit the revised chapters of the License Application to the Director, NMSS, using an appropriate method listed in Title 10 of the Code of Federal Regulations (10 CFR) 70.5(a), and a copy to the appropriate NRC Regional Office.
S-3 NFS shall utilize, for setpoint determinations, conservative engineering analyses that account for safety limits, instrument and system accuracies, response times, instrument drift, manufacturers data and operating experience. The analysis for each safety setpoint shall be a formal calculation and shall be documented for each IROFS interlock and alarm.
S-4 The vaults will be protected by barriers with an equivalent 2-hour fire resistance rating.
S-5 Active and administrative controls for flammable liquids and gasses must be operable in the fire area where flammable liquids and gasses are present during KAST processing.
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION Page 5 of 11 License Number SNM-124 MATERIALS LICENSE SUPPLEMENTARY SHEET Docket or Reference Number 70-143 Amendment 21 S-6 The licensee shall maintain and execute the response measures in the Emergency Plan, Revision 27, transmitted by letter dated September 24, 2021, or as further revised by the licensee consistent with 10 CFR 70.32(i).
(a)
The licensee is granted an exemption from performing the biennial emergency plan exercise listed in 10 CFR 70.22(i)(3)(xii) in calendar year 2021 but must complete said exercise within 35 months of the previously evaluated emergency plan exercise which occurred on September 18, 2019. Following that evaluated exercise, the licensee will conduct biennial emergency plan exercises in odd number years.
S-7 NFS shall inform the NRC within 30 days of receipt of a violation notice from the State of Tennessee Division of Air Pollution or Water Pollution Control, or receipt of modified requirements for a State-issued National Pollutant Discharge Elimination System permit.
S-8 Notwithstanding the requirements of 10 CFR 70.50(b)(1), the licensee is exempted from the requirement to report unplanned contamination events when the following conditions are met:
(a)
The event occurs in a restricted area in a building which is maintained inaccessible to the public by multiple access controls; (b)
The area was controlled for contamination before the event occurred, the release of radioactive material is under control, and no contamination has spread outside the area; (c)
Radiation safety personnel trained in contamination control are readily available; (d)
Equipment and facilities that may be needed for contamination control are readily available; and (e)
The otherwise reportable unplanned contamination event is documented in the licensees Corrective Action Program.
S-9 Introduction of special nuclear material into the new portions of the processes to be used for U-metal services shall not occur until the NRC provides written notice to the licensee that the NRC has completed an operational readiness review. The operational readiness review will verify whether: (1) commitments in the amendment request have been fulfilled; (2) management measures for IROFS have been implemented; (3) the new processes have been constructed in accordance with design requirements and startup plans reflect as-built conditions; and (4) other actions necessary for safe operations are complete, including but not limited to: (a) the process safety information and integrated safety analysis summaries are updated for all nodes of the U-metal services to reflect final design, including those nodes that are not part of the license amendment application; (b) the items relied on for safety are fully defined (e.g., completed boundary packages) and based on as-built conditions (e.g., set points established); (c) the plans referenced in the license (e.g., Fundamental Nuclear Material Control Plan, physical protection plans, emergency plan) are updated and appropriately documented, in accordance with the applicable provisions of 10 CFR 70.32, to reflect the as-built conditions and any changes needed
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION Page 6 of 11 License Number SNM-124 MATERIALS LICENSE SUPPLEMENTARY SHEET Docket or Reference Number 70-143 Amendment 21 for U-metal services; (d) the material control and accounting controls, as specified in the updated Fundamental Nuclear Material Control Plan and applicable to the U-metal services, are in place; and (e) a license amendment to update the financial assurance instruments for the decommissioning of U-metal services has been approved by the NRC staff.
SAFEGUARDS CONDITIONS Section 1.0 - FUNDAMENTAL NUCLEAR MATERIAL CONTROL (FNMC) PLANS SG-1.1 The licensee shall follow its Fundamental Nuclear Material Control Plan with respect to all activities involving strategic special nuclear material. The approved plan consists of the following revisions, or as further revised by the licensee in accordance with 10 CFR 70.32(c):
General Discussion ------------------------
Rev. 9 (dated September 2009)
Section 1 - Process Monitoring ---------
Rev. 28 (dated October 2015)
Section 2 - Item Monitoring --------------
Rev. 11 (dated July 2013)
Section 3 - Alarm Resolution ------------
Rev. 11 (dated October 2015)
Section 4 - QA & Accounting ------------
Rev. 23 (dated July 2013)
Note: The Plan may include examples in one or more annexes.
SG-1.2 The licensee shall follow its Fundamental Nuclear Material Control Plan for SNM of Low-Enriched Uranium with respect to all activities involving special nuclear material of low strategic significance. The approved plan consists of the following revisions, or as further revised by the licensee in accordance with 10 CFR 70.32(c):
Section 1 - General Discussion --------------------------------------- Rev. 8 (dated September 2012)
Section 2 - SNM Confirmation and Tracking ---------------------- Rev. 5 (dated December 2010)
Section 3 - Management Structure ---------------------------------- Rev. 10 (dated December 2010)
Section 4 - MC&A Measurements ----------------------------------- Rev. 7 (dated December 2010)
Section 5 - Physical Inventories -------------------------------------- Rev. 5 (dated December 2010)
Section 6 - Item Control ------------------------------------------------ Rev. 6 (dated November 2011)
Section 7 - Resolving Shipper/Receiver Differences ----------- Rev. 3 (dated December 2010)
Section 8 - Periodic Assessment of the MC&A System ------- Rev. 5 (dated December 2010)
Section 9 - Record Keeping ------------------------------------------- Rev. 1 (dated February 1993)
Note: The Plan may include examples in one or more annexes.
Section 2.0 - ADDITIONAL FNMC CONDITIONS SG-2.1 Notwithstanding the requirements of 10 CFR 74.59(f)(2)(viii) to remeasure, at the time of physical inventory, any in-process SSNM for which the validity of a prior measurement has not been assured by tamper-safing, the licensee may book for high enriched uranium (HEU) physical inventory purposes:
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION Page 7 of 11 License Number SNM-124 MATERIALS LICENSE SUPPLEMENTARY SHEET Docket or Reference Number 70-143 Amendment 21 (a) process holdup quantities determined by nondestructive assay measurements in manufacturing facilities performed prior to the start of an inventory, in accordance with the controls described in Section 4.5.2.3.2 of the Plan identified in Condition SG-1.1; and (b) pre-listed material introduced to process in the manufacturing facilities prior to the start of an inventory, in accordance with the controls described in Section 4.5.2.3.2 of the Plan identified in Condition SG-1.1.
SG-2.2 Notwithstanding, the requirement of 10 CFR 74.53(b)(1) to have a process detection capability for each unit process, the process units listed in Section 1.1.5.2 of the Plan identified in Condition SG-1.1 shall be exempt from such detection capability; and the licensee's process monitoring system shall be comprised of the control units described in Section 1.3 (and all sub-sections therein) of the above-mentioned Plan.
SG-2.3 Notwithstanding, the requirements of 10 CFR 74.31(c)(2) for low-enriched uranium (LEU) and 10 CFR 74.59(d)(1) for SSNM to maintain a system of measurements to substantiate both the element and fissile isotope content of all SNM received, inventoried, shipped or discarded, SNM measured by the licensee for U-233, U-235, or Pu-239 by nondestructive assay techniques need not be measured for total element if the calculated element content is based on the measured isotope content which, in turn, is traceable to an isotopic abundance measurement at the area of generation.
SG-2.4 Notwithstanding, the requirement of 10 CFR 74.59(e)(8) to establish and maintain control limits at the 0.05 and 0.001 levels of significance for all HEU related measurements, the licensee may use one and two scale divisions as being equivalent to the 0.05 and 0.001 control levels, respectively, for mass measurements.
SG-2.5 Notwithstanding, the requirements of 10 CFR 74.59(f)(1) and 74.59(f)(2)(viii) to measure and inventory all SSNM, the licensee may determine process exhaust ventilation system inventory quantities in accordance with Section 4.5.3.5 of the Plan identified in Condition SG-1.1.
SG-2.6 Notwithstanding, the requirements of 10 CFR 74.59(e)(8) relative to actions to be taken when replicate measurement data exceed a 0.001 control limit, the licensee shall comply with Section 4.4.1.7.3.4 of the Plan identified in Condition SG-1.1.
SG-2.7 Notwithstanding, the requirement of 10 CFR 74.59(e)(4) that allows the pooling of data which has been shown to be not significantly different on the basis of appropriate statistical tests, the licensee may pool data from equivalent scales without testing.
SG-2.8 Notwithstanding, the requirement of 10 CFR 74.31(c)(3) and of 74.59(e)(3)(i) to measure control standards for all measurement systems for the purpose of determining bias, and notwithstanding the requirement of 10 CFR 74.31(c)(4) and of 74.59(e)(8) to maintain a statistical control system to monitor such control standard measurements, the licensee need not measure nor monitor such control standards for point calibrated, bias-free systems. To be regarded as bias-free, a measurement system must be calibrated by one or more measurements of a representative
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION Page 8 of 11 License Number SNM-124 MATERIALS LICENSE SUPPLEMENTARY SHEET Docket or Reference Number 70-143 Amendment 21 standard(s) each time process unknowns are measured, and the measurement value assigned to a given unknown is based on the associated calibration.
SG-2.9 Notwithstanding, the requirement of 10 CFR 74.15 to include limit of error data on DOE/NRC Form-741 for all SNM shipments, the licensee is exempt from including such data on 741 Forms associated with waste burial shipments.
SG-2.10 Notwithstanding, the requirement of 10 CFR 74.59(f)(1)(i) to calculate the SEID associated with each HEU ID value, the licensee need not determine such SEID for MBA-7 whenever its ID is less than 300 grams U-235.
SG-2.11 Notwithstanding the requirements of 10 CFR 74.31(c)(3) and (c)(4), the licensee is exempted from calculating the SEID and measurement system biases associated with LEU physical inventories provided that the calculated inventory difference does not exceed 1,000 grams U-235.
SG-2.12 Notwithstanding, the requirements of 10 CFR 74.59(d)(1) and Section 4.3 of the facilitys FNMC Plan identified in Condition SG-1.1 to measure the uranium element and isotope content of all strategic SNM, the licensee shall provide assigned values for the 2S cylinder heels identified in the December 31, 2009, request letter. This one-time exemption will expire when all of these cylinders are shipped from the site.
Section 3.0 - PHYSICAL PROTECTION REQUIREMENTS:
SG-3.1 The licensee shall follow the physical protection plan entitled NFS Physical Protection Plan for Protection of Category I High Enriched Uranium (Strategic Special Nuclear Material), Revision 26, submitted by letter dated May 15, 2023, and as the plan may be further revised in accordance with the provisions of 10 CFR 70.32(e).
SG-3.2 The licensee shall follow the safeguards contingency plan titled "NFS Safeguards Contingency Response Plan, Revision 1, and as the plan may be further revised in accordance with the provisions of 10 CFR 70.32(g).
SG-3.3 The licensee shall follow the training and qualification plan titled "NFS Site Security Training and Qualification Plan, Revision 4, and as the plan may be further revised in accordance with the provisions of 10 CFR 70.32(e).
SG-3.4 The licensee shall comply with the provisions of the plan entitled Physical Protection Plan for the Protection of Category II Moderate Enriched Uranium (Special Nuclear Material), Revision 004, submitted by letter dated March 24, 2020, and as the plan may be further revised in accordance with the provisions of 10 CFR 70.32(e), as follows:
(a)
The licensee may implement the fixed site security provisions (Chapters 1-6) only after notifying the NRC at least 90 days before implementation begins and submitting for NRC approval a revised, standalone plan that reflects the changes to the security posture of the facility. The notice and submittal shall be made in writing to the Director, Division of Fuel
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION Page 9 of 11 License Number SNM-124 MATERIALS LICENSE SUPPLEMENTARY SHEET Docket or Reference Number 70-143 Amendment 21 Management, NRC Headquarters, with a copy to the Director, Division of Fuel Facility Inspection, NRC Region II; and (b)
The licensee shall comply with the transportation security provisions (Chapters 7-13).
SG-3.5 The licensee shall comply with the provisions of the plan entitled Physical Protection Plan for Protection of Category III Low-Enriched Uranium (Special Nuclear Material), Revision 009, submitted by letter dated February 15, 2021, and as the plan may be further revised in accordance with the provisions of 10 CFR 70.32(e).
SG-3.6 See Sensitive Conditions.
SG-3.7 Notwithstanding the requirements of 10 CFR 73.46(b) for security officers to qualify and requalify every 12 months, the licensee may requalify security officers within a 12 calendar-month period where a calendar-month is considered to include any day of the month. This is in addition to exemption issued in 1999 (ADAMS No. ML11325A131) and renewed in 2012 (ADAMS No.
ML102780085), which permits the licensee to extend the requalification period for 30 days due to unforeseen scheduling matters.
SG-3.8 Deleted per Amendment 17.
SG-3.9 Until December 31, 2024, or 180 days after publication of the final Regulatory Guides (specifically, Regulatory Guide 5.62, Revision 3, and Regulatory Guide 5.87, Revision 1), whichever is later, the licensee is exempt from implementation of the revised definitions for the terms "Contraband," and "Time of Discovery," in 10 CFR 73.2, "Definitions," and the recently revised requirements in 10 CFR Part 73, Subpart T, "Security Notifications, Reports, and Recordkeeping,"
10 CFR 73.1200(a) through 10 CFR 73.1200(t), "Notification of Physical Security Events,"
10 CFR 73.1205(a) through 10 CFR 73.1205(e), "Written Follow-up Reports of Physical Security Events," 10 CFR 73.1210(a) through 10 CFR 73.1210(h), "Record keeping of Physical Security Events," and 10 CFR 73.1215(a) through 10 CFR 73.1215(f), "Suspicious Activity Reports." The licensee shall comply with the commitments captured in its letter dated November 20, 2023, as supplemented by letter dated February 19, 2024. Specifically, the licensee shall:
1.
Continue to comply with security event reporting, as previously required in 10 CFR 73.71, Reporting of Safeguards Events, and 10 CFR Part 73, Appendix G, "Reportable Safeguards Events," and consistent with its current NRC-approved security plan and its site security procedures.
2.
Continue to comply with the existing definition for Discovery (time of) as defined in Revision 7 of NEI 03-12, "Template for the Security Plan, Training and Qualification Plan, Safeguards Contingency Plan, [and Independent Spent Fuel Storage Installation Security Program]."
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION Page 10 of 11 License Number SNM-124 MATERIALS LICENSE SUPPLEMENTARY SHEET Docket or Reference Number 70-143 Amendment 21 3.
Remain capable of voluntarily reporting suspicious activity to the NRC and other federal agencies for the duration of the requested exemption term.
4.
Continue to implement the established Corrective Action Plan that identifies items within the security program considered adverse to regulatory compliance.