ML24060A169

From kanterella
Jump to navigation Jump to search
NRC Slides for March 7, 2024 Regulatory Conference with Constellation Nuclear Regarding Braidwood
ML24060A169
Person / Time
Site: Braidwood 
(NPF-077)
Issue date: 03/07/2024
From:
NRC/RGN-III/DORS/EB1
To:
References
Download: ML24060A169 (1)


Text

U.S. Nuclear Regulatory Commission Region III Regulatory Conference Thursday, March 7, 2024 Constellation Nuclear Braidwood Station

Agenda

  • Welcome and Opening Remarks
  • Description of Apparent Violation
  • Licensees Presentation
  • NRC Questions
  • NRC Caucus
  • NRC Clarifying Questions
  • Questions and Comments from the Public to the NRC

Apparent Violation Title 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Actions, requires, in part, that measures shall be established to assure that conditions adverse to quality, such as failures, malfunctions, deficiencies, deviations, defective materials and equipment, and nonconformances are promptly identified and corrected.

From June 1, 2023, to September 23, 2023, the licensee failed to establish measures to assure that conditions adverse to quality are promptly identified and corrected. Specifically, the licensee failed to identify and correct a deficiency on the 2B auxiliary feedwater pumps diesel engine after receiving results from a May 19, 2023, lubricating oil sample on June 1, 2023, indicating viscosity levels in the alert range.

The NRC characterized this issue as preliminarily greater than green.