Certificate of Compliance No.. 9379, Rev. No. 1, for the Model No. 1105-SD Package Letter and Safety Evaluation Report
ML24058A493
Person / Time
Site: 07109379
Issue date: 03/11/2024
From: Yoira Diaz-Sanabria
Storage and Transportation Licensing Branch
To: Backus C
Orano Federal Services
Shared Package
ML24058A491 List:
References
EPID L-2024-RNW-0005
Download: ML24058A493 (1)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 11, 2024 Chris Backus, Packaging Licensing Manager Orano Federal Services LLC 32125 32nd Ave. S.

Suite 220 Federal Way WA 98003

SUBJECT:

REVISION NO. 1 OF CERTIFICATE OF COMPLIANCE NO. 9379 FOR THE MODEL NO. 1105-SD PACKAGE

Dear Chris Backus:

As requested by your letter dated January 24, 2024, enclosed is Certificate of Compliance No. 9379, Revision No. 1, for the Model No. 1105-SD package. Changes made to the enclosed certificate are indicated by vertical lines in the margin. The staff's safety evaluation report is also enclosed.

Orano Federal Services LLC is registered as a certificate holder and user of the package under the general license provisions of Title 10 of the Code of Federal Regulations (CFR) Section 71.17, General license: NRC approved package, or 49 CFR 173.471, Requirements for U.S.

Nuclear Regulatory Commission approved packages. The approval constitutes authority to use the package for shipment of radioactive material and for the package to be shipped in accordance with the provisions of 49 CFR 173.471.

If you have any questions regarding this certificate, please contact Pierre Saverot of my staff.

Sincerely, Yoira K. Diaz-Sanabria, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-9379 EPID No. L-2024-RNW-0005

Enclosures:

1. CoC No. 9379, Rev. No. 1
2. Safety Evaluation Report cc w/encls 1 & 2: R. Boyle, DOT J. Shenk, DOE c/o L.F. Gelder Yoira K. Diaz-Sanabria Digitally signed by Yoira K. Diaz-Sanabria Date: 2024.03.11 14:50:32 -04'00'

ML24058A491 (PKG), ML24058A493 (Ltr&SER),

ML24058A492 Encl. 1)

OFFICE NMSS/DFM NMSS/DFM NMSS/DFM NAME PSaverot SFigueroa YDiaz-Sanabria DATE 02/28/2024 02/28/2024 03/05/2024

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 SAFETY EVALUATION REPORT Docket No. 71-9379 Model No.1105-SD Certificate of Compliance No. 9379 Revision No. 1 EVALUATION By letter dated January 24, 2024, (Agencywide Documents Access and Management System

[ADAMS] Accession No. ML24024A239), Orano Federal Services LLC requested renewal of Certificate of Compliance (CoC) No. 9379, for the Model No. 1105-SD package. There have been no changes to the use or design of the package since its last approval and no other changes were requested.

The certificate has been updated to Revision No. 1.

CONDITIONS The following changes have been made to the CoC:

Item No.3.a was revised with the new address of the certificate holder.

Condition No. 10 extends the validity of Revision No. 0 of the certificate to March 31, 2024.

Condition No. 11 (previously numbered 10) was updated to reflect the March 31, 2029, expiration date of Revision No. 1 of the certificate.

CONCLUSION Based on the statements and representations in the renewal request, the staff finds that these changes do not affect the ability of the package to meet the requirements of Title 10 of the Code of Federal Regulations Part 71.

Issued with CoC No. 9379, Revision No. 1.