ML24031A664
Jump to navigation
Jump to search
| ML24031A664 | |
| Person / Time | |
|---|---|
| Site: | HI-STORM 100 |
| Issue date: | 01/31/2024 |
| From: | Holtec |
| To: | Office of Nuclear Material Safety and Safeguards |
| Shared Package | |
| ML24031A659 | List: |
| References | |
| 5021074 | |
| Download: ML24031A664 (1) | |
Text
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2115090 Proposed Rev. 4.1A 5-46 Table 5.4.6 DOSE RATES ADJACENT TO THE HI-STORM UMAX MODULE WITH VERSION B LID FOR NORMAL CONDITIONS MPC-37 DESIGN BASIS ZIRCALOY CLAD FUEL Location Value Side of the VVM lid Adjacent to the Inlet Vent 22 mremr/hr Table 5.4.7 DESIGN BASIS DOSE RATE LIMITS Location Value Side of HI-TRAC 3500 mrem/hr Standard Lid (On the side of the closure lid approximately midheight) 66 mremr/hr Version B Lid (On the side of the closure lid approximately midheight and adjacent to the inlet vent) 22 mremr/hr to Holtec Letter 5021074