International, HI-STORM Umax FSAR Proposed FSAR Revision 2.1A
ML24031A662
Person / Time
Site: HI-STORM 100
Issue date: 01/31/2024
From:
Holtec
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML24031A659 List:
References
5021074
Download: ML24031A662 (1)


Text

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2115090 Proposed Rev. 2.1A 5-45 Table 5.4.6 DOSE RATES ADJACENT TO THE HI-STORM UMAX MODULE WITH VERSION B LID FOR NORMAL CONDITIONS MPC-37 DESIGN BASIS ZIRCALOY CLAD FUEL Location Value Side of the VVM lid Adjacent to the Inlet Vent 22 mremr/hr Table 5.4.7 DESIGN BASIS DOSE RATE LIMITS Location Value Side of HI-TRAC 3500 mrem/hr Standard Lid (On the side of the closure lid approximately midheight) 66 mremr/hr Version B Lid (On the side of the closure lid approximately midheight and adjacent to the inlet vent) 22 mremr/hr to Holtec Letter 5021074