Text
Browns Ferry Nuclear Plant Unit 2 Surveillance Procedure 2-SR-3.1.6.1 BPWS Compliance Verification Revision 0006 Quality Related Level of Use: Continuous Use Level of Use or Other Information: 2913A Effective Date: 01-28-2019 Responsible Organization:
RXE, Reactor Engineering Prepared By:
Jesse V King Approved By:
Daniel D Coffey
BFN Unit 2 BPWS Compliance Verification 2-SR-3.1.6.1 Rev. 0006 Page 4 of 7
1.0 INTRODUCTION
1.1 Purpose This procedure verifies compliance with Banked Position Withdrawal Sequence (BPWS). This is to ensure the assumptions of the control rod drop accident analyses are satisfied.
1.2 Scope This procedure is performed in conformance with requirements specified in Technical Specification (TS) Surveillance Requirement (SR) 3.1.6.1.
1.3 Frequency This procedure is to be performed once every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
1.4 Conditions This procedure can be performed in Modes 1 thru 4.
1.5 Applicability Modes 1 and 2 with THERMAL POWER d 10% RTP (SR-3.1.6.1).
2.0 REFERENCES
2.1 Performance References A.
2-SR-3.1.3.5(A), Control Rod Coupling Integrity Check.
2.2 Developmental References A.
Technical Specifications Section 3.1.6.1, Rod Pattern Control Surveillance.
B.
Updated Final Safety Analysis Report Section 7.7, Reactor Manual Control System.
C.
Updated Final Safety Analysis Report Section 7.16, Plant Process Computer.
2.3 Commitments None
BFN Unit 2 BPWS Compliance Verification 2-SR-3.1.6.1 Rev. 0006 Page 6 of 7 Date ________
6.0 PERFORMANCE
[1]
IF all rods are fully inserted, THEN INITIAL this step AND N/A Steps 6.0[2] to 6.0[4].
(OTHERWISE N/A this step.)
_____(AC)
NOTE At any time the RWM is inoperable, the control rod pattern in the step below may be obtained by recording the control rod positions from Panel 2-9-5 on Attachment 1.
[2]
ATTACH a printout of the current control rod pattern using the Integrated Computer System (ICS).
[3]
RECORD the current RWM sequence and group, either from the RWM display or from the in use copy of 2-SR-3.1.3.5(A).
________ RWM Sequence ________ RWM Group
[4]
VERIFY that all control rods in the pattern obtained in Step 6.0[2] are within the insert and withdraw limits specified in 2-SR-3.1.3.5(A) for the current RWM group.
_____(AC) 7.0 POST PERFORMANCE ACTIVITY
[1]
[2]
NOTIFY UO procedure is complete.
[3]
NOTIFY US procedure is complete.
8.0 RECORDS All completed portions of this procedure and STS are to be maintained per NPG-SPP-31.2, Records Management.
8.1 Attachments, Control Rod Pattern Form
BFN Unit 2 BPWS Compliance Verification 2-SR-3.1.6.1 Rev. 0006 Page 7 of 7 (Page 1 of 1)
Control Rod Pattern Form Date:________
59 Time:________
55 51 47 43 39 35 31 27 23 19 15 11 7
3 2
6 10 14 18 22 26 30 34 38 42 46 50 54 58 Remarks:
Recorded By:_____________________________