Text
KP-NRC-2312-004 Enclosure 1 Changes to PSAR Chapter 13 (Non-Proprietary)
Preliminary Safety Analysis Report Accident Analysis Figure of Merit Acceptance Criterion Applicable Events Mass loss of structural graphite Bounded by the MHA release Salt Spill, PHSS break due to oxidation Peak structural graphite Generally bounded by temperature Salt Spill, Reactivity temperaturetime time curves derived from the Insertion, Increase in Heat assumed MHA structural graphite Removal, Loss of Forced temperaturetime curve Circulation, PHSS break Peak pebble carbon matrix Generally bounded by temperature Salt Spill, Reactivity temperaturetime time curves derived from the Insertion, Increase in Heat assumed MHA pebble carbon matrix Removal, Loss of Forced temperaturetime curve Circulation, PHSS break Peak TRISO temperaturetime ex Generally bounded by temperature PHSS break vessel time curves derived from the assumed MHA fuel temperature time curve Amount of materials at risk Less than limit derived to bound PHSS break, Radioactive released total releases of the postulated Release from Subsystem event to less than the MHA or Component Kairos Power Hermes 2, Units 1 and 2 1323 Revision 0