December 2023 Docket No. 71-9390 OPTIMUS-L (OPTImal Modular Universal Shipping Cask)

SAFETY ANALYSIS REPORT Initial Submission of Updates to the Permitted Isotopes NON-PROPRIETARY VERSION Revision 23D to ED20230183 Page 1 of 2 Page 1 of 2 No. 71-9390 for OPTIMUS-L Proposed Changes for Revision 3 of Certificate of Compliance Initial Submission of Updates to the Permitted Isotopes NAC OPTIMUS-L SAR, Revision 23D December 2023 to ED20230183 Page 2 of 2 Page 2 of 2 CoC Sections (revised)

CoC Page 5 of 7 5.(b)(2)

Maximum quantity of material per package (continued)

Table 4 - TRU Waste and IFW Activity Limits for Key Isotopes Isotope Activity Limits (Ci) per package configuration No SIA inside the CCV cavity 1-inch SIA inside the CCV cavity 21/4-inch SIA inside the CCV cavity Co-60 8.197 x 10-2 1.632 x 10-1 4.284 x 10-1 Cs-137(1) 4.066 x 10-01 1.077 4.228 Cf-252 1.217 x 10-2 1.289 x 10-2 1.469 x 10-2 Cm-244 3.819 x 102 4.074 x 102 1.654 x 102 (1) Includes Ba-137m daughter to ED20230183 Page 1 of 2 List of Calculations Initial Submission of Updates to the Permitted Isotopes NAC OPTIMUS-L SAR, Revision 23D December 2023 to ED20230183 Page 2 of 2 List of Calculations

1. 70000.14-5104 Rev. 0 CALCULATIONS ARE PROPRIETARY AND WITHHELD IN THEIR ENTIRETY PER 10 CFR 2.390 to ED20230183 Page 1 of 2 List of SAR Changes NAC OPTIMUS-L SAR, Revision 23D (Docket No 71-9390)

December 2023 to ED20230183 Page 2 of 2 List of Changes for the OPTIMUS-L SAR, Revision 23D Note: The List of Effective Pages and the Chapter Table of Contents, List of Figures, and List of Tables have been revised accordingly to reflect the list of changes detailed below.

Chapter 1

  • Page 1.2-10, modified text, where indicated.
  • Page 1.2-15, modified 2nd Isotope and added Note 5. Deleted 3rd Isotope and its information.

Chapter 2

  • No changes.

Chapter 3

  • No changes.

Chapter 4

  • No changes.

Chapter 5

  • Page 5.1-2, modified text in the first full paragraph on the page, where indicated.
  • Page 5.1-4, modified text in Table 5.1-2 where indicated. Deleted Case 3 and renamed Cases 4 and 5 to 3 and 4.
  • Page 5.5-12, modified text where indicated.
  • Page 5.5-13, modified text in columns 1, 7, 8, and 9 of Table 5.5-9, where indicated.

Chapter 7

  • Pages 7.5-3 thru 7.5-8, modified Table 7.5-1, where indicated
  • Pages 7.5-9 thru 7.5-17, modified Table 7.5-2, where indicated Chapter 8
  • No changes.

to ED20230183 Page 1 of 1 List of Effective Pages and SAR Changed Pages Initial Submission of Updates to the Permitted Isotopes NAC OPTIMUS-L SAR, Revision 23D (Docket No 71-9390)

December 2023

December 2023 Docket No. 71-9390 OPTIMUS-L (OPTImal Modular Universal Shipping Cask)

SAFETY ANALYSIS REPORT NON-PROPRIETARY VERSION Revision 23D

OPTIMUS-L Safety Analysis Report December 2023 Docket No. 71-9390 Revision 23D List of Effective Pages Page 1 of 2 Chapter 1 Page 1-i thru 1-ii.......................... Revision 1 Page 1-1....................................... Revision 1 Page 1.1-1 thru 1.1-2.................... Revision 1 Page 1.2-1 thru 1.2-9.................... Revision 1 Page 1.2-10............................. Revision 23D Page 1.2-11 thru 1.2-14................ Revision 1 Page 1.2-15............................. Revision 23D Page 1.2-16 thru 1.2-18................ Revision 1 Page 1.3-1 thru 1.3-3.................... Revision 1 14 drawings (see Section 1.3)

Chapter 2 Page 2-i thru 2-vi......................... Revision 1 Page 2-1....................................... Revision 1 Page 2.1-1 thru 2.1-20.................. Revision 1 Page 2.2-1 thru 2.2-11.................. Revision 1 Page 2.3-1 thru 2.3-4.................... Revision 1 Page 2.4-1.................................... Revision 1 Page 2.5-1 thru 2.5-14.................. Revision 1 Page 2.6-1 thru 2.6-37.................. Revision 1 Page 2.7-1 thru 2.7-52.................. Revision 1 Page 2.8-1.................................... Revision 1 Page 2.9-1.................................... Revision 1 Page 2.10-1.................................. Revision 1 Page 2.11-1.................................. Revision 1 Page 2.12-1 thru 2.12-57.............. Revision 1 Chapter 3 Page 3-i thru 3-iii......................... Revision 1 Page 3-1....................................... Revision 1 Page 3.1-1 thru 3.1-5.................... Revision 1 Page 3.2-1 thru 3.2-5.................... Revision 1 Page 3.3-1 thru 3.3-20.................. Revision 1 Page 3.4-1 thru 3.4-18.................. Revision 1 Page 3.5-1 thru 3.5-7.................... Revision 1 Chapter 4 Page 4-i thru 4-ii.......................... Revision 1 Page 4-1....................................... Revision 1 Page 4.1-1 thru 4.1-3.................... Revision 1 Page 4.2-1.................................... Revision 1 Page 4.3-1.................................... Revision 1 Page 4.4-1.................................... Revision 1 Page 4.5-1 thru 4.5-24.................. Revision 1 Chapter 5 Page 5-i thru 5-iii......................... Revision 1 Page 5-1....................................... Revision 1 Page 5.1-1.................................... Revision 1 Page 5.1-2............................... Revision 23D Page 5.1-3.................................... Revision 1 Page 5.1-4............................... Revision 23D Page 5.2-1 thru 5.2-4.................... Revision 1 Page 5.3-1 thru 5.3-8.................... Revision 1 Page 5.4-1 thru 5.4-14.................. Revision 1 Page 5.5-1 thru 5.5-11.................. Revision 1 Page 5.5-12 thru 5.5-13........... Revision 23D Chapter 6 Page 6-i thru 6-vii........................ Revision 1 Page 6-1....................................... Revision 1 Page 6.1-1 thru 6.1-2.................... Revision 1 Page 6.2-1 thru 6.2-4.................... Revision 1 Page 6.3-1 thru 6.3-23.................. Revision 1 Page 6.4-1 thru 6.4-15.................. Revision 1 Page 6.5-1 thru 6.5-18.................. Revision 1 Page 6.6-1 thru 6.6-20.................. Revision 1 Page 6.7-1.................................... Revision 1 Page 6.8-1 thru 6.8-20.................. Revision 1 Page 6.9-1.................................... Revision 1 Page 6.9.1-1 thru 6.9.1-2.............. Revision 1 Page 6.9.2-1 thru 6.9.2-2.............. Revision 1 Page 6.9.3-1 thru 6.9.3-19............ Revision 1 Page 6.9.4-1................................. Revision 1 Page 6.9.5-1................................. Revision 1 Page 6.9.6-1................................. Revision 1 Page 6.9.7-1................................. Revision 1 Page 6.9.8-1 thru 6.9.8-7.............. Revision 1 Page 6.10-1 thru 6.10-2................ Revision 1 Chapter 7 Page 7-i........................................ Revision 1 Page 7-1 thru 7-3.......................... Revision 1 Page 7.1-1 thru 7.1-5.................... Revision 1

OPTIMUS-L Safety Analysis Report December2023 Docket No. 71-9390 Revision 23D List of Effective Pages (contd)

Page 2 of 2 Page 7.2-1 thru 7.2-2.................... Revision 1 Page 7.3-1 thru 7.3-2.................... Revision 1 Page 7.4-1.................................... Revision 1 Page 7.5-1 thru 7.5-2.................... Revision 1 Page 7.5-3 thru 7.5-17............. Revision 23D Page 7.5-18 thru 7.5-24................ Revision 1 Chapter 8 Page 8-i thru 8-ii.......................... Revision 1 Page 8-1....................................... Revision 1 Page 8.1-1 thru 8.1-5.................... Revision 1 Page 8.2-1 thru 8.2-8.................... Revision 1 Page 8.3-1.................................... Revision 1

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 1.2-10 Maximum Quantity of TRU Waste Contents per Package:

1. Greater than Type A quantities of radioactive material in the form of solids or dewatered materials in secondary containers.
2. Greater than Type A quantities of radioactive material in the form of activated reactor components or segments of components of waste from a nuclear process or power plant.
3. That quantity of any radioactive material not generating spontaneously more than 100 thermal watts of radioactive decay heat.
4. TRU waste not exceeding the fissile gram equivalents (FGE) of fissile radioactive material in Table 1.2-1 for the specified criticality configuration limits.
5. TRU waste contents shall comply with regulatory dose rates, as demonstrated in accordance with Chapter 7, Attachment 7.5-1. Note: Maximum activity limits for key individual gamma-emitting contents (e.g., Co-60 and Cs-137 including Ba-137m daughter product) and neutron-emitting contents (e.g., Cf-252 and Cm-244) are provided in Table 1.2-3 Loading Restrictions:
1. TRU waste contents shall be in secondary containers (e.g., drums or boxes).
2. TRU waste contents with a total decay heat exceeding 50 watts shall be inerted with helium gas.
3. Explosives, corrosives, non-radioactive pyrophorics, and sealed items containing compressed and/or flammable gas (e.g., aerosol cans, lecture bottles, etc.) are prohibited.

Pyrophoric radionuclides may be present only in residual amounts less than 1 wt%. All nonradioactive pyrophoric material be reacted (or oxidized) and/or otherwise rendered nonreactive prior to placement in a secondary container (e.g., drum).

4. Free liquids shall not exceed 1% of the CCV cavity volume.
5. Maximum weight of the CCV contents, including TRU waste, secondary containers, and internal structures (e.g., CCV bottom support plate, SIA, etc.) and dunnage or shoring shall not exceed 3,500 pounds (1,587 kg).

1.2.2.2 Irradiated Fuel Waste The materials in Irradiated Fuel Waste (IFW) are restricted to low enriched uranium (LEU) fuel and metal structural components (e.g., cladding, liners, baskets, etc.) meeting the following requirements and restrictions.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 1.2-15 Table 1.2-3 TRU Waste and IFW Activity Limits for Key Isotopes Isotope Activity Limits(1) for Package Configurations (Ci)

Bare(2) 1-inch SIA(3) 21/4-inch SIA(4)

Co-60 8.197E-02 1.632E-01 4.284E-01 Cs-137(5) 4.066E-01 1.077E+00 4.228E+00 Cf-252 1.217E-02 1.289E-02 1.469E-02 Cm-244 3.819E+02 4.074E+02 4.654E+02 Notes:

(1) Maximum activity limits are provided for entire content in a package. The corresponding maximum resultant dose rates from these isotopes at the listed activity limits are shown for the bare case (i.e., package without an SIA) in Table 5.1-2. Compliance with external dose rate limits shall be demonstrated with the isotope inventory of the individual package contents using the dose rate per curie values listed in Tables 7.5-1 and 7.5-2, as outlined in.5.1.

(2) Package configuration without an SIA inside the CCV cavity.

(3) Package configured with the 1-inch SIA inside the CCV cavity.

(4) Package configured with the 21/4-inch SIA inside the CCV cavity.

(5) Includes Ba-137m daughter.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 5.1-2 and cab (occupied position) dose rates are only calculated from the side of the package, as the package is only transported in the upright position.

For TRU waste, the contents of the package are variable, and the final isotope inventory is different for each TRU waste drum or irradiated fuel waste liner, the maximum dose rates are strongly dependent on the specific contents. As an example, maximum dose rates are calculated for the maximum allowable quantity of four individual isotopes. The isotopes considered are Co-60, Cs-137, Cf-252, and Cm-244. Examples of the maximum activity in a package of the conveyance that would result in the limiting dose rate at 90% of the regulatory limit are provided in Table 5.1-2, along with the resulting total dose rates at each location. It should be noted from this table that, due to the relatively thin layers of shielding provided by the packaging, the maximum isotopic activities permissible in the contents are very limited. The primary content intended for transport in the package is drums of TRU waste with relatively low activity. Thus, the relative hazard of the contents is limited.

For TRISO compact contents, the payload is composed of fresh, unirradiated fuel, therefore dose rates on package surfaces will be negligible. Based on the significant shielding presented by the package design and that the payload is unirradiated material fresh fuel, no shielding evaluations are required.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 5.1-4 Table 5.1-2 - Maximum External Dose Rate Examples Case(1)

Isotope (Activity)

Condition Location Dose Rate (mrem/hr)

Limit (mrem/hr) 1 Co-60 (8.197E-02 Ci)

NCT Package Surface 180.00 200 Trailer Surface 30.96 200 2-meter 4.65 10 Cab(2) 1.5 2

HAC 1-meter 48.63 1000 2

Cs-137(3)

(4.066E-01 Ci)

NCT Package Surface 180.00 200 Trailer Surface 30.00 200 2-meter 4.43 10 Cab(2) 1.4 2

HAC 1-meter 49.47 1000 3

Cf-252 (1.217E-02 Ci)

NCT Package Surface 180.00 200 Trailer Surface 30.66 200 2-meter 4.50 10 Cab(2) 1.5 2

HAC 1-meter 50.87 1000 4

Cm-244 (3.819E+02 Ci)

NCT Package Surface 180.00 200 Trailer Surface 30.66 200 2-meter 4.50 10 Cab(2) 1.5 2

HAC 1-meter 51.09 1000 Notes:

1. Cases listed are for each isotope analyzed individually: each case is for one package containing a maximum activity of the respective isotope.
2. For a maximum load, there must be a distance to the drivers cab of at least 20 ft from the centerline of the package.
3. Includes Ba-137m daughter.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 5.5-12 5.5.3 Example Cases This section provides sample calculations of demonstrating compliance for a hypothetical group of packages with bare casks that are not secured to the center of the trailer (i.e. using the Dose Rate/Ci values from Table 7.5-1). The same example calculations can be applied to a centered package, with or without SIAs, using the Dose Rate/Ci values in Table 7.5-2.

To provide an example of the demonstration of compliance for a group of 10 hypothetical packages, dose rates are calculated for 10 sample isotope inventories (labeled Content ID 1 - 10) in Table 5.5-9 using the Dose Rates/Ci values from Table 7.5-1. The results in this table show that the calculated dose rates for the package surface, 2-meter, and HAC 1-meter are far below the limit, indicating that all packages are acceptable for transport from this hypothetical group of packages. Note that the trailer surface dose rate is not calculated because it is always bounded by the package surface location (i.e. the package surface dose rate limit will always be reached before the trailer surface).

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 5.5-13 Table 5.5-9 - Sample Dose Rate Calcuations Content ID Radionuclide Activity (Ci)

Dose Rate (mrem/hr)

Th-228*

Th-230 Co-60 Zn-65 Fe-59 Cr-51 2-meter Package Surface HAC 1-meter 1

0.004 4.30 0.001 0.006 0.0001 0.640 0.976 25.682 7.021 2

0.009 10.23 0.002 0.001 0.0004 0.230 0.882 22.458 6.050 3

0.003 2.58 0.001 0.005 0.0003 0.201 0.534 13.758 3.733 4

0.008 9.28 0.006 0.006 0.0001 0.112 1.170 29.509 7.944 5

0.004 3.98 0.004 0.003 0.0023 0.300 0.978 25.095 6.806 6

0.004 4.62 0.002 0.007 0.0050 0.205 0.924 23.568 6.379 7

0.007 8.69 0.001 0.012 0.0046 0.104 0.996 25.152 6.774 8

0.001 0.81 0.005 0.010 0.0031 0.246 1.045 26.719 7.256 9

0.003 2.99 0.002 0.002 0.0096 0.356 1.095 28.147 7.646 10 0.005 5.21 0.020 0.005 0.0096 1.200 3.560 91.642 24.928

  • Includes daughters Ra-224, Rn-220, Po-216, Pb-212, Bi-212, Tl-208, and Po-212.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-3 Table 7.5-1 - Bare Cask Dose Rate/Ci Values (6 Pages)

Isotope NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Package Surface 2-meter 1-meter Ac2254 1.632E+02 6.194E+00 4.464E+01 Ac2275 2.659E-01 9.896E-03 7.316E-02 Ac228 7.639E+02 2.986E+01 2.076E+02 Ag108m6 1.372E+03 5.224E+01 3.764E+02 Ag109m 2.839E-03 1.031E-04 7.701E-04 Ag110m7 2.408E+03 9.399E+01 6.551E+02 Am241 2.160E-02 7.970E-04 5.922E-03 Am242m8 6.080E+00 2.276E-01 1.657E+00 Am2439 7.024E+01 2.546E+00 1.936E+01 Am246 6.132E+02 2.337E+01 1.683E+02 Au198 3.367E+02 1.258E+01 9.272E+01 Ba133 2.213E+02 8.103E+00 6.135E+01 Ba14010 2.292E+03 9.143E+01 6.144E+02 Be10 7.196E-01 2.611E-02 1.979E-01 Bi207 1.320E+03 5.165E+01 3.585E+02 Bi210 4.939E+00 1.814E-01 1.360E+00 Bi21211 1.186E+03 4.817E+01 3.135E+02 Bk247 4.725E+01 1.712E+00 1.305E+01 Bk24912 5.819E-04 2.160E-05 1.620E-04 Bk250 8.285E+02 3.265E+01 2.250E+02 C14 2.008E-03 7.244E-05 5.477E-04 Ca45 3.160E-02 1.140E-03 8.627E-03 Cd113 7.546E-02 2.725E-03 2.064E-02 Cd113m 7.351E-01 2.668E-02 2.022E-01 Cd115m 4.278E+01 1.653E+00 1.167E+01 Ce139 2.894E+01 1.044E+00 7.897E+00 Ce141 1.799E+01 6.493E-01 4.910E+00 Ce14413 8.839E+01 3.396E+00 2.403E+01 Cf249 1.992E+02 7.291E+00 5.519E+01 Cf250 2.969E+02 1.145E+01 8.808E+01 Cf251 3.325E+01 1.202E+00 9.120E+00 Cf252 1.480E+04 5.716E+02 4.182E+03 Cf25314 9.606E-02 3.550E-03 2.634E-02 4Includes daughters Fr221, At217, Bi213, Tl209, Po213, and Pb209.

5Includes daughter Fr223.

6Includes daughter Ag108.

7Includes daughter Ag110.

8Includes daughters Am242 and Np238.

9Includes daughter Np239.

10Includes daughter La140.

11Includes daughters Tl208 and Po212.

12Includes daughter Am245.

13 Includes daughters Pr144m and Pr144.

14Includes daughter Cm249.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-4 Table 7.5-1 - Bare Cask Dose Rate/Ci Values (6 Pages)

Isotope NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Package Surface 2-meter 1-meter Cf254 4.221E+05 1.628E+04 1.253E+05 Cl36 1.524E+00 5.563E-02 4.193E-01 Cm240 1.958E-02 7.468E-04 5.461E-03 Cm242 2.749E-02 1.057E-03 7.735E-03 Cm243 4.834E+01 1.751E+00 1.334E+01 Cm244 4.713E-01 1.820E-02 1.338E-01 Cm245 2.116E+01 7.633E-01 5.772E+00 Cm246 1.045E+02 4.037E+00 2.974E+01 Cm24715 2.603E+02 9.709E+00 7.171E+01 Cm248 3.226E+04 1.245E+03 9.210E+03 Cm250 8.653E+03 3.476E+02 2.311E+03 Co57 3.608E+01 1.304E+00 9.847E+00 Co58 8.946E+02 3.468E+01 2.445E+02 Co60 2.196E+03 8.737E+01 5.932E+02 Cr51 2.343E+01 8.583E-01 6.496E+00 Cs134 1.310E+03 5.025E+01 3.589E+02 Cs135 8.786E-03 3.170E-04 2.397E-03 Cs13716 4.427E+02 1.680E+01 1.217E+02 Cu64 1.665E+02 6.296E+00 4.566E+01 Dy159 2.658E-03 9.727E-05 7.367E-04 Es252 1.564E+02 6.020E+00 4.276E+01 Es253 2.208E-01 8.194E-03 6.181E-02 Es254 5.888E-01 2.158E-02 1.634E-01 Es254m 2.031E+02 7.842E+00 6.000E+01 Eu149 2.115E+01 7.785E-01 5.846E+00 Eu150 1.222E+03 4.643E+01 3.349E+02 Eu152 9.828E+02 3.860E+01 2.665E+02 Eu154 1.087E+03 4.276E+01 2.949E+02 Eu155 7.757E+00 2.799E-01 2.116E+00 Fe55 4.672E-08 1.686E-09 1.275E-08 Fe59 1.090E+03 4.336E+01 2.946E+02 Gd152 1.533E-05 6.087E-07 4.191E-06 Gd153 7.741E+00 2.793E-01 2.112E+00 Hf175 2.055E+02 7.530E+00 5.695E+01 Hf181 3.338E+02 1.242E+01 9.196E+01 Hg203 1.056E+02 3.829E+00 2.923E+01 Ho166m 1.266E+03 4.871E+01 3.463E+02 I129 1.012E-03 3.652E-05 2.761E-04 I131 2.542E+02 9.382E+00 7.031E+01 In113m 1.525E+02 5.584E+00 4.226E+01 15Includes daughter Pu243.

16Includes daughter Ba137m.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-5 Table 7.5-1 - Bare Cask Dose Rate/Ci Values (6 Pages)

Isotope NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Package Surface 2-meter 1-meter In114m17 6.442E+01 2.433E+00 1.766E+01 In115 3.908E-01 1.416E-02 1.073E-01 In115m 1.084E+02 3.972E+00 3.006E+01 Ir194 9.515E+01 3.594E+00 2.611E+01 K40 1.457E+02 5.829E+00 3.908E+01 K42 3.723E+02 1.490E+01 9.958E+01 Kr85 3.479E+00 1.293E-01 9.563E-01 La140 2.149E+03 8.609E+01 5.753E+02 Lu177 1.675E+01 6.071E-01 4.627E+00 Lu177m 1.098E+02 4.057E+00 3.028E+01 Mn54 7.495E+02 2.918E+01 2.047E+02 Na22 1.983E+03 7.731E+01 5.389E+02 Na24 3.715E+03 1.524E+02 9.788E+02 Nb91 1.411E+00 5.325E-02 3.873E-01 Nb94 1.399E+03 5.423E+01 3.824E+02 Nb95 6.499E+02 2.506E+01 1.778E+02 Nd144 1.391E-05 5.542E-07 3.747E-06 Ni59 3.325E-04 1.255E-05 9.128E-05 Ni63 9.354E-11 3.446E-12 2.676E-11 Np235 1.563E-01 5.641E-03 4.265E-02 Np237 1.503E+00 5.431E-02 4.118E-01 Np239 6.997E+01 2.537E+00 1.929E+01 Np240 9.007E+02 3.473E+01 2.463E+02 Os185 5.249E+02 2.002E+01 1.441E+02 Os19418 9.515E+01 3.594E+00 2.611E+01 P32 1.688E+01 6.269E-01 4.643E+00 P33 2.853E-02 1.029E-03 7.787E-03 Pa231 2.094E+01 7.661E-01 5.802E+00 Pa233 1.325E+02 4.854E+00 3.670E+01 Pb21019 4.939E+00 1.814E-01 1.360E+00 Pb21220 1.250E+03 5.052E+01 3.314E+02 Pm145 7.343E-07 2.705E-08 2.101E-07 Pm146 6.037E+02 2.300E+01 1.656E+02 Pm147 1.515E-02 5.465E-04 4.133E-03 Pm148m21 1.713E+03 6.550E+01 4.690E+02 Po209 3.964E+00 1.531E-01 1.084E+00 Po210 1.023E-02 3.973E-04 2.799E-03 Pr143 2.862E+00 1.047E-01 7.882E-01 17Includes daughter In114.

18Includes daughter Ir194.

19Includes daughter Bi210.

20Includes daughters Bi212, Tl208, and Po212.

21Includes daughter Pm148.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-6 Table 7.5-1 - Bare Cask Dose Rate/Ci Values (6 Pages)

Isotope NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Package Surface 2-meter 1-meter Pu236 1.498E-02 5.543E-04 4.099E-03 Pu238 3.993E-03 1.529E-04 1.100E-03 Pu239 2.427E-02 8.957E-04 6.690E-03 Pu240 2.070E-02 7.921E-04 5.847E-03 Pu24122 1.295E-03 4.687E-05 3.562E-04 Pu242 1.500E+00 5.796E-02 4.278E-01 Pu243 2.576E+00 9.408E-02 7.117E-01 Pu24423 6.167E+02 2.375E+01 1.732E+02 Pu246 5.001E+01 1.810E+00 1.377E+01 Ra22324 1.884E+02 7.012E+00 5.193E+01 Ra22425 1.256E+03 5.073E+01 3.331E+02 Ra22526 1.633E+02 6.197E+00 4.466E+01 Ra22627 1.490E+03 5.893E+01 4.016E+02 Rb86 1.069E+02 4.202E+00 2.902E+01 Rb87 3.818E-02 1.378E-03 1.043E-02 Re188 5.710E+01 2.165E+00 1.562E+01 Rh102 3.969E+02 1.504E+01 1.089E+02 Rh106 2.642E+02 1.008E+01 7.230E+01 Rn22228 1.489E+03 5.889E+01 4.012E+02 Ru103 3.479E+02 1.301E+01 9.580E+01 S35 2.947E-03 1.063E-04 8.039E-04 Sb124 1.677E+03 6.640E+01 4.514E+02 Sb125 3.337E+02 1.257E+01 9.181E+01 Sb126 2.252E+03 8.599E+01 6.181E+02 Sc46 1.784E+03 7.027E+01 4.849E+02 Se75 1.793E+02 6.541E+00 4.947E+01 Se79 3.447E-03 1.244E-04 9.405E-04 Sm145 1.142E-02 4.267E-04 3.147E-03 Sm146 2.302E-05 9.047E-07 6.478E-06 Sm147 1.782E-05 7.047E-07 4.947E-06 Sm148 1.419E-05 5.648E-07 3.836E-06 Sm151 1.095E-08 3.978E-10 2.976E-09 Sn11329 1.552E+02 5.684E+00 4.302E+01 Sn119m 5.096E-09 1.877E-10 1.458E-09 Sn123 1.639E+01 6.238E-01 4.482E+00 22Includes daughter U237.

23Includes daughters U240 and Np240m.

24Includes daughters Rn219, Po215, Pb211, Bi211, Po211, and Tl207.

25Includes daughters Rn220, Po216, Pb212, Bi212, Tl208, and Po212.

26Includes daughters Ac225, Fr221, At217, Bi213, Tl209, Po213, and Pb209.

27Includes daughters Rn222, Po218, Pb214, Bi214, and Po214.

28Includes daughters Po218, Pb214, Bi214, and Po214.

29Includes daughter In113m.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-7 Table 7.5-1 - Bare Cask Dose Rate/Ci Values (6 Pages)

Isotope NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Package Surface 2-meter 1-meter Sn12630 1.253E+03 4.755E+01 3.444E+02 Sr85 4.302E+02 1.624E+01 1.181E+02 Sr89 1.234E+01 4.569E-01 3.396E+00 Sr9031 3.583E+01 1.343E+00 9.839E+00 Ta182 1.119E+03 4.438E+01 3.024E+02 Tb157 8.867E-08 3.267E-09 2.537E-08 Tb160 9.230E+02 3.613E+01 2.512E+02 Tc97m 2.362E-04 8.582E-06 6.408E-05 Tc99 5.142E-02 1.856E-03 1.405E-02 Tc99m 3.249E+01 1.172E+00 8.864E+00 Te121 4.456E+02 1.681E+01 1.223E+02 Te121m 1.332E+02 4.922E+00 3.669E+01 Te123m 3.067E+01 1.107E+00 8.369E+00 Te125m 1.022E-01 3.687E-03 2.788E-02 Te127 5.022E+00 1.861E-01 1.384E+00 Te127m32 4.979E+00 1.845E-01 1.372E+00 Te129 5.352E+01 2.015E+00 1.470E+01 Te129m33 5.985E+01 2.269E+00 1.643E+01 Th227 8.045E+01 2.926E+00 2.227E+01 Th22834 1.257E+03 5.075E+01 3.332E+02 Th229 1.497E+01 5.414E-01 4.108E+00 Th230 3.897E-02 1.413E-03 1.069E-02 Th231 5.624E-01 2.031E-02 1.538E-01 Th232 8.745E-03 3.173E-04 2.387E-03 Th23435 4.400E+01 1.681E+00 1.203E+01 Tl206 3.784E-02 1.472E-03 1.034E-02 Tm168 9.607E+02 3.708E+01 2.627E+02 Tm170 2.926E+00 1.070E-01 8.059E-01 Tm171 7.424E-07 2.711E-08 2.054E-07 U232 3.991E-02 1.451E-03 1.094E-02 U233 7.298E-02 2.659E-03 2.015E-02 U234 1.751E-02 6.363E-04 4.780E-03 U23536 3.800E+01 1.373E+00 1.040E+01 U236 8.760E-03 3.198E-04 2.394E-03 U238 1.389E-01 5.353E-03 3.994E-02 U239 1.365E+01 5.172E-01 3.744E+00 30Includes daughter Sb126m.

31Includes daughter Y90.

32Includes daughter Te127.

33Includes daughter Te129.

34Includes daughters Ra224, Rn220, Po216, Pb212, Bi212, Tl208, and Po212.

35Includes daughters Pa234m and Pa234.

36Includes daughter Th231.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-8 Table 7.5-1 - Bare Cask Dose Rate/Ci Values (6 Pages)

Isotope NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Package Surface 2-meter 1-meter W181 4.166E-02 1.503E-03 1.137E-02 W185 2.352E-01 8.510E-03 6.451E-02 W18837 5.802E+01 2.198E+00 1.587E+01 Xe127 1.401E+02 5.092E+00 3.875E+01 Xe131m 7.087E-01 2.557E-02 1.933E-01 Y88 2.421E+03 9.760E+01 6.482E+02 Y89m 8.392E+02 3.282E+01 2.287E+02 Y90 3.507E+01 1.316E+00 9.630E+00 Y90m 4.376E+02 1.621E+01 1.207E+02 Y91 1.636E+01 6.149E-01 4.485E+00 Zn65 5.307E+02 2.105E+01 1.437E+02 Zr88 2.301E+02 8.426E+00 6.377E+01 Zr90m 2.102E+03 8.680E+01 5.524E+02 Zr93 7.448E-11 2.744E-12 2.131E-11 Zr9538 6.428E+02 2.479E+01 1.759E+02 37Includes daughter Re188.

38Includes daughter Nb95m

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-9 Table 7.5-2 - OPTIMUS-L SIA Configuration Dose Rate/Ci Results (9 Pages)

Isotope No SIA NCT Dose Rate (mrem/hr/Ci) 1-inch SIA NCT Dose Rate (mrem/hr/Ci) 21/4-inch SIA NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Pkg Surface 2-meter Pkg Surface 2-meter Pkg Surface 2-meter 1-meter Ac22539 1.632E+02 3.995E+00 5.792E+01 1.356E+00 1.621E+01 3.728E-01 4.464E+01 Ac22740 2.659E-01 6.401E-03 7.597E-02 1.723E-03 1.664E-02 3.684E-04 7.316E-02 Ac228 7.639E+02 1.943E+01 3.452E+02 8.397E+00 1.188E+02 2.771E+00 2.076E+02 Ag108m41 1.372E+03 3.383E+01 5.207E+02 1.206E+01 1.356E+02 2.953E+00 3.764E+02 Ag109m 2.839E-03 6.643E-05 3.695E-06 7.701E-08 0.000E+00 0.000E+00 7.701E-04 Ag110m42 2.408E+03 6.104E+01 1.080E+03 2.609E+01 3.616E+02 8.332E+00 6.551E+02 Am241 2.160E-02 5.158E-04 6.475E-03 1.489E-04 3.049E-03 7.042E-05 5.922E-03 Am242m43 6.080E+00 1.473E-01 1.574E+00 3.712E-02 4.341E-01 9.973E-03 1.657E+00 Am24344 7.024E+01 1.641E+00 1.256E+01 2.688E-01 1.366E+00 2.981E-02 1.936E+01 Am246 6.132E+02 1.509E+01 2.285E+02 5.315E+00 6.068E+01 1.334E+00 1.683E+02 Au198 3.367E+02 8.096E+00 1.070E+02 2.393E+00 2.160E+01 4.546E-01 9.272E+01 Ba133 2.213E+02 5.275E+00 5.847E+01 1.301E+00 9.276E+00 2.035E-01 6.135E+01 Ba14045 2.292E+03 5.932E+01 1.161E+03 2.914E+01 4.749E+02 1.156E+01 6.144E+02 Be10 7.196E-01 1.686E-02 1.227E-01 2.651E-03 1.384E-02 2.987E-04 1.979E-01 Bi207 1.320E+03 3.347E+01 5.965E+02 1.444E+01 2.037E+02 4.716E+00 3.585E+02 Bi210 4.939E+00 1.173E-01 1.176E+00 2.610E-02 2.007E-01 4.340E-03 1.360E+00 Bi21246 1.186E+03 3.137E+01 6.609E+02 1.716E+01 3.130E+02 7.986E+00 3.135E+02 Bk247 4.725E+01 1.101E+00 8.647E+00 1.832E-01 8.986E-01 1.971E-02 1.305E+01 Bk24947 5.819E-04 1.395E-05 2.624E-04 6.145E-06 1.839E-04 4.335E-06 1.620E-04 39 Includes daughters Fr221, At217, Bi213, Tl209, Po213, and Pb209.

40 Includes daughter Fr223.

41 Includes daughter Ag108.

42 Includes daughter Ag110 43 Includes daughters Am242 and Np238.

44 Includes daughter Np239.

45 Includes daughter La140.

46 Includes daughters Tl208 and Po212.

47 Includes daughter Am245.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-10 Table 7.5-2 - OPTIMUS-L SIA Configuration Dose Rate/Ci Results (9 Pages)

Isotope No SIA NCT Dose Rate (mrem/hr/Ci) 1-inch SIA NCT Dose Rate (mrem/hr/Ci) 21/4-inch SIA NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Pkg Surface 2-meter Pkg Surface 2-meter Pkg Surface 2-meter 1-meter Bk250 8.285E+02 2.120E+01 3.929E+02 9.585E+00 1.381E+02 3.196E+00 2.250E+02 C14 2.008E-03 4.678E-05 2.022E-04 4.295E-06 9.287E-06 1.803E-07 5.477E-04 Ca45 3.160E-02 7.363E-04 3.352E-03 7.119E-05 1.732E-04 3.450E-06 8.627E-03 Cd113 7.546E-02 1.759E-03 9.060E-03 1.928E-04 6.132E-04 1.275E-05 2.064E-02 Cd113m 7.351E-01 1.723E-02 1.286E-01 2.778E-03 1.481E-02 3.200E-04 2.022E-01 Cd115m 4.278E+01 1.075E+00 1.760E+01 4.238E-01 5.673E+00 1.308E-01 1.167E+01 Ce139 2.894E+01 6.744E-01 2.945E+00 6.255E-02 1.353E-01 2.626E-03 7.897E+00 Ce141 1.799E+01 4.193E-01 1.852E+00 3.936E-02 8.858E-02 1.733E-03 4.910E+00 Ce14448 8.839E+01 2.201E+00 3.391E+01 8.187E-01 1.127E+01 2.675E-01 2.403E+01 Cf249 1.992E+02 4.748E+00 5.252E+01 1.170E+00 8.352E+00 1.832E-01 5.519E+01 Cf250 2.969E+02 7.399E+00 2.812E+02 6.748E+00 2.490E+02 5.913E+00 8.808E+01 Cf251 3.325E+01 7.750E-01 4.587E+00 9.741E-02 3.730E-01 7.965E-03 9.120E+00 Cf252 1.480E+04 3.699E+02 1.396E+04 3.350E+02 1.225E+04 2.895E+02 4.182E+03 Cf25349 9.606E-02 2.298E-03 2.299E-02 5.197E-04 4.586E-03 9.824E-05 2.634E-02 Cf254 4.222E+05 1.052E+04 4.005E+05 9.608E+03 3.549E+05 8.428E+03 1.253E+05 Cl36 1.524E+00 3.596E-02 3.143E-01 6.891E-03 4.582E-02 9.874E-04 4.193E-01 Cm240 1.959E-02 4.832E-04 1.577E-02 3.768E-04 1.364E-02 3.215E-04 5.461E-03 Cm242 2.749E-02 6.839E-04 2.374E-02 5.684E-04 2.033E-02 4.798E-04 7.735E-03 Cm243 4.834E+01 1.126E+00 8.626E+00 1.829E-01 8.840E-01 1.937E-02 1.334E+01 Cm244 4.713E-01 1.178E-02 4.418E-01 1.060E-02 3.868E-01 9.143E-03 1.338E-01 Cm245 2.116E+01 4.929E-01 2.158E+00 4.584E-02 1.032E-01 2.023E-03 5.772E+00 Cm246 1.045E+02 2.612E+00 9.855E+01 2.364E+00 8.653E+01 2.046E+00 2.974E+01 Cm24750 2.603E+02 6.249E+00 8.109E+01 1.810E+00 1.601E+01 3.365E-01 7.171E+01 Cm248 3.226E+04 8.057E+02 3.042E+04 7.298E+02 2.674E+04 6.324E+02 9.210E+03 48 Includes daughters Pr144m and Pr144.

49 Includes daughter Cm249.

50 Includes daughter Pu243.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-11 Table 7.5-2 - OPTIMUS-L SIA Configuration Dose Rate/Ci Results (9 Pages)

Isotope No SIA NCT Dose Rate (mrem/hr/Ci) 1-inch SIA NCT Dose Rate (mrem/hr/Ci) 21/4-inch SIA NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Pkg Surface 2-meter Pkg Surface 2-meter Pkg Surface 2-meter 1-meter Cm250 8.653E+03 2.258E+02 4.551E+03 1.155E+02 1.962E+03 4.858E+01 2.311E+03 Co57 3.608E+01 8.420E-01 3.937E+00 8.433E-02 2.584E-01 5.240E-03 9.847E+00 Co58 8.946E+02 2.253E+01 3.808E+02 9.030E+00 1.156E+02 2.594E+00 2.445E+02 Co60 2.196E+03 5.674E+01 1.103E+03 2.735E+01 4.202E+02 9.878E+00 5.932E+02 Cr51 2.343E+01 5.591E-01 6.265E+00 1.397E-01 1.005E+00 2.204E-02 6.496E+00 Cs134 1.310E+03 3.260E+01 5.255E+02 1.232E+01 1.474E+02 3.252E+00 3.589E+02 Cs135 8.786E-03 2.047E-04 8.897E-04 1.890E-05 4.089E-05 7.939E-07 2.397E-03 Cs13751 4.427E+02 1.090E+01 1.672E+02 3.882E+00 4.257E+01 9.143E-01 1.217E+02 Cu64 1.665E+02 4.091E+00 5.995E+01 1.374E+00 1.458E+01 3.164E-01 4.566E+01 Dy159 2.658E-03 6.328E-05 6.871E-04 1.526E-05 1.074E-04 2.356E-06 7.367E-04 Es252 1.564E+02 3.907E+00 6.295E+01 1.482E+00 1.834E+01 4.090E-01 4.276E+01 Es253 2.208E-01 5.316E-03 8.840E-02 2.040E-03 4.431E-02 1.034E-03 6.181E-02 Es254 5.888E-01 1.404E-02 1.653E-01 3.702E-03 3.821E-02 8.640E-04 1.634E-01 Es254m 2.031E+02 5.069E+00 1.882E+02 4.520E+00 1.646E+02 3.910E+00 6.000E+01 Eu149 2.115E+01 5.050E-01 5.744E+00 1.278E-01 1.002E+00 2.179E-02 5.846E+00 Eu150 1.222E+03 3.010E+01 4.518E+02 1.054E+01 1.221E+02 2.741E+00 3.349E+02 Eu152 9.828E+02 2.506E+01 4.547E+02 1.111E+01 1.625E+02 3.799E+00 2.665E+02 Eu154 1.087E+03 2.779E+01 5.087E+02 1.244E+01 1.810E+02 4.213E+00 2.949E+02 Eu155 7.757E+00 1.807E-01 7.868E-01 1.671E-02 3.614E-02 7.015E-04 2.116E+00 Fe55 4.672E-08 1.089E-09 4.753E-09 1.010E-10 2.183E-10 4.238E-12 1.275E-08 Fe59 1.090E+03 2.814E+01 5.455E+02 1.351E+01 2.069E+02 4.858E+00 2.946E+02 Gd152 1.533E-05 3.951E-07 8.534E-06 2.127E-07 4.345E-06 1.055E-07 4.191E-06 Gd153 7.741E+00 1.804E-01 7.853E-01 1.668E-02 3.607E-02 7.002E-04 2.112E+00 Hf175 2.055E+02 4.903E+00 5.511E+01 1.228E+00 8.890E+00 1.947E-01 5.695E+01 Hf181 3.338E+02 8.004E+00 1.001E+02 2.234E+00 1.937E+01 4.081E-01 9.196E+01 51 Includes daughter Ba137m.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-12 Table 7.5-2 - OPTIMUS-L SIA Configuration Dose Rate/Ci Results (9 Pages)

Isotope No SIA NCT Dose Rate (mrem/hr/Ci) 1-inch SIA NCT Dose Rate (mrem/hr/Ci) 21/4-inch SIA NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Pkg Surface 2-meter Pkg Surface 2-meter Pkg Surface 2-meter 1-meter Hg203 1.056E+02 2.460E+00 2.119E+01 4.489E-01 2.336E+00 5.153E-02 2.923E+01 Ho166m 1.266E+03 3.160E+01 5.093E+02 1.199E+01 1.483E+02 3.313E+00 3.463E+02 I129 1.012E-03 2.359E-05 1.017E-04 2.161E-06 4.671E-06 9.068E-08 2.761E-04 I131 2.542E+02 6.103E+00 7.342E+01 1.654E+00 1.371E+01 2.994E-01 7.031E+01 In113m 1.525E+02 3.638E+00 4.076E+01 9.087E-01 6.538E+00 1.434E-01 4.226E+01 In114m52 6.442E+01 1.577E+00 2.164E+01 5.002E-01 5.499E+00 1.214E-01 1.766E+01 In115 3.908E-01 9.142E-03 6.169E-02 1.327E-03 6.324E-03 1.362E-04 1.073E-01 In115m 1.084E+02 2.587E+00 2.900E+01 6.464E-01 4.653E+00 1.021E-01 3.006E+01 Ir194 9.515E+01 2.333E+00 3.298E+01 7.730E-01 8.904E+00 2.034E-01 2.611E+01 K40 1.457E+02 3.790E+00 7.554E+01 1.890E+00 3.075E+01 7.365E-01 3.908E+01 K42 3.723E+02 9.664E+00 1.909E+02 4.821E+00 8.017E+01 1.958E+00 9.958E+01 Kr85 3.479E+00 8.379E-02 9.882E-01 2.223E-02 2.007E-01 4.312E-03 9.563E-01 La140 2.149E+03 5.586E+01 1.113E+03 2.806E+01 4.642E+02 1.133E+01 5.753E+02 Lu177 1.675E+01 3.906E-01 3.156E+00 6.705E-02 3.394E-01 7.453E-03 4.627E+00 Lu177m 1.098E+02 2.621E+00 3.067E+01 6.821E-01 5.520E+00 1.174E-01 3.028E+01 Mn54 7.495E+02 1.896E+01 3.277E+02 7.807E+00 1.022E+02 2.300E+00 2.047E+02 Na22 1.983E+03 5.032E+01 8.848E+02 2.147E+01 3.001E+02 6.951E+00 5.389E+02 Na24 3.715E+03 9.927E+01 2.183E+03 5.695E+01 1.058E+03 2.686E+01 9.788E+02 Nb91 1.411E+00 3.460E-02 5.003E-01 1.141E-02 1.169E-01 2.509E-03 3.873E-01 Nb94 1.399E+03 3.521E+01 5.965E+02 1.412E+01 1.799E+02 4.023E+00 3.824E+02 Nb95 6.499E+02 1.626E+01 2.690E+02 6.314E+00 7.772E+01 1.724E+00 1.778E+02 Nd144 1.391E-05 3.599E-07 7.147E-06 1.794E-07 3.082E-06 7.541E-08 3.747E-06 Ni59 3.325E-04 8.154E-06 1.179E-04 2.688E-06 2.755E-05 5.912E-07 9.128E-05 Ni63 9.354E-11 2.210E-12 7.617E-17 1.587E-18 0.000E+00 0.000E+00 2.676E-11 Np235 1.563E-01 3.643E-03 1.579E-02 3.353E-04 7.251E-04 1.408E-05 4.265E-02 52 Includes daughter In114.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-13 Table 7.5-2 - OPTIMUS-L SIA Configuration Dose Rate/Ci Results (9 Pages)

Isotope No SIA NCT Dose Rate (mrem/hr/Ci) 1-inch SIA NCT Dose Rate (mrem/hr/Ci) 21/4-inch SIA NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Pkg Surface 2-meter Pkg Surface 2-meter Pkg Surface 2-meter 1-meter Np237 1.503E+00 3.502E-02 1.969E-01 4.181E-03 1.609E-02 3.441E-04 4.118E-01 Np239 6.997E+01 1.635E+00 1.253E+01 2.682E-01 1.362E+00 2.973E-02 1.929E+01 Np240 9.007E+02 2.257E+01 3.708E+02 8.800E+00 1.112E+02 2.502E+00 2.463E+02 Os185 5.249E+02 1.299E+01 2.042E+02 4.764E+00 5.446E+01 1.184E+00 1.441E+02 Os19453 9.515E+01 2.333E+00 3.298E+01 7.730E-01 8.904E+00 2.034E-01 2.611E+01 P32 1.688E+01 4.056E-01 4.751E+00 1.076E-01 1.000E+00 2.194E-02 4.643E+00 P33 2.853E-02 6.647E-04 2.994E-03 6.359E-05 1.507E-04 2.986E-06 7.787E-03 Pa231 2.094E+01 4.980E-01 5.388E+00 1.195E-01 8.387E-01 1.839E-02 5.802E+00 Pa233 1.325E+02 3.160E+00 3.513E+01 7.826E-01 5.664E+00 1.239E-01 3.670E+01 Pb21054 4.939E+00 1.173E-01 1.176E+00 2.610E-02 2.007E-01 4.340E-03 1.360E+00 Pb21255 1.250E+03 3.288E+01 6.743E+02 1.745E+01 3.146E+02 8.021E+00 3.314E+02 Pm145 7.343E-07 1.735E-08 1.927E-14 4.844E-16 7.946E-15 1.948E-16 2.101E-07 Pm146 6.037E+02 1.488E+01 2.277E+02 5.264E+00 5.933E+01 1.299E+00 1.656E+02 Pm147 1.515E-02 3.529E-04 1.546E-03 3.284E-05 7.241E-05 1.412E-06 4.133E-03 Pm148m56 1.713E+03 4.250E+01 6.716E+02 1.573E+01 1.864E+02 4.129E+00 4.690E+02 Po209 3.964E+00 9.938E-02 1.629E+00 3.858E-02 4.905E-01 1.103E-02 1.084E+00 Po210 1.023E-02 2.579E-04 5.789E-03 1.380E-04 3.185E-03 7.378E-05 2.799E-03 Pr143 2.862E+00 6.765E-02 6.231E-01 1.371E-02 9.503E-02 2.050E-03 7.882E-01 Pu236 1.498E-02 3.586E-04 5.446E-03 1.270E-04 3.449E-03 8.041E-05 4.099E-03 Pu238 3.993E-03 9.902E-05 3.371E-03 8.042E-05 2.881E-03 6.771E-05 1.100E-03 Pu239 2.427E-02 5.801E-04 7.648E-03 1.735E-04 2.808E-03 6.412E-05 6.690E-03 Pu240 2.070E-02 5.124E-04 1.706E-02 4.083E-04 1.468E-02 3.470E-04 5.847E-03 53 Includes daughter Ir194.

54 Includes daughter B210.

55 Includes daughters Bi212, Tl208, and Po212.

56 Includes daughter Pm148.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-14 Table 7.5-2 - OPTIMUS-L SIA Configuration Dose Rate/Ci Results (9 Pages)

Isotope No SIA NCT Dose Rate (mrem/hr/Ci) 1-inch SIA NCT Dose Rate (mrem/hr/Ci) 21/4-inch SIA NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Pkg Surface 2-meter Pkg Surface 2-meter Pkg Surface 2-meter 1-meter Pu24157 1.295E-03 3.021E-05 2.125E-04 4.528E-06 2.107E-05 4.579E-07 3.562E-04 Pu242 1.500E+00 3.750E-02 1.404E+00 3.370E-02 1.228E+00 2.905E-02 4.278E-01 Pu24458 6.168E+02 1.539E+01 4.301E+02 1.028E+01 3.135E+02 7.392E+00 1.732E+02 Pu246 5.001E+01 1.165E+00 8.156E+00 1.729E-01 7.749E-01 1.686E-02 1.377E+01 Ra22359 1.884E+02 4.537E+00 5.614E+01 1.270E+00 1.185E+01 2.599E-01 5.193E+01 Ra22460 1.256E+03 3.302E+01 6.756E+02 1.747E+01 3.148E+02 8.025E+00 3.331E+02 Ra22561 1.633E+02 3.997E+00 5.793E+01 1.356E+00 1.621E+01 3.728E-01 4.466E+01 Ra22662 1.490E+03 3.826E+01 7.186E+02 1.787E+01 2.798E+02 6.733E+00 4.016E+02 Rb86 1.069E+02 2.718E+00 4.905E+01 1.196E+00 1.734E+01 4.028E-01 2.902E+01 Rb87 3.818E-02 8.896E-04 4.156E-03 8.828E-05 2.287E-04 4.607E-06 1.043E-02 Re188 5.710E+01 1.402E+00 1.961E+01 4.611E-01 5.482E+00 1.244E-01 1.562E+01 Rh102 3.969E+02 9.723E+00 1.430E+02 3.293E+00 3.581E+01 7.846E-01 1.089E+02 Rh106 2.642E+02 6.538E+00 1.002E+02 2.351E+00 2.809E+01 6.310E-01 7.230E+01 Rn22263 1.489E+03 3.823E+01 7.185E+02 1.787E+01 2.798E+02 6.732E+00 4.012E+02 Ru103 3.479E+02 8.381E+00 1.122E+02 2.516E+00 2.309E+01 4.864E-01 9.580E+01 S35 2.947E-03 6.867E-05 2.974E-04 6.317E-06 1.366E-05 2.651E-07 8.039E-04 Sb124 1.677E+03 4.310E+01 8.205E+02 2.040E+01 3.189E+02 7.655E+00 4.514E+02 Sb125 3.337E+02 8.127E+00 1.163E+02 2.659E+00 2.702E+01 5.765E-01 9.181E+01 Sb126 2.252E+03 5.561E+01 8.691E+02 2.024E+01 2.322E+02 5.088E+00 6.181E+02 Sc46 1.784E+03 4.553E+01 8.370E+02 2.032E+01 2.902E+02 6.684E+00 4.849E+02 Se75 1.793E+02 4.209E+00 3.801E+01 8.210E-01 5.175E+00 1.111E-01 4.947E+01 57 Includes daughter U237.

58 Includes daughters U240 and Np240m.

59 Includes daughters Rn219, Po215, Pb211, Bi211, Po211, and Tl207.

60 Includes daughters Rn220, Po216, Pb212, Bi212, Tl208, and Po212.

61 Includes daughters Ac225, Fr221, At217, Bi213, Tl209, Po213, and Pb209.

62 Includes daughters Rn222, Po218, Pb214, Bi214, and Po214.

63 Includes daughters Po218, Pb214, Bi214, and Po214.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-15 Table 7.5-2 - OPTIMUS-L SIA Configuration Dose Rate/Ci Results (9 Pages)

Isotope No SIA NCT Dose Rate (mrem/hr/Ci) 1-inch SIA NCT Dose Rate (mrem/hr/Ci) 21/4-inch SIA NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Pkg Surface 2-meter Pkg Surface 2-meter Pkg Surface 2-meter 1-meter Se79 3.447E-03 8.033E-05 3.477E-04 7.386E-06 1.597E-05 3.100E-07 9.405E-04 Sm145 1.142E-02 2.746E-04 3.618E-03 8.083E-05 7.233E-04 1.519E-05 3.147E-03 Sm146 2.302E-05 5.862E-07 1.593E-05 3.898E-07 1.097E-05 2.628E-07 6.478E-06 Sm147 1.782E-05 4.570E-07 1.095E-05 2.707E-07 6.535E-06 1.575E-07 4.947E-06 Sm148 1.419E-05 3.667E-07 7.419E-06 1.859E-07 3.333E-06 8.141E-08 3.836E-06 Sm151 1.095E-08 2.562E-10 1.370E-11 2.855E-13 0.000E+00 0.000E+00 2.976E-09 Sn11364 1.552E+02 3.702E+00 4.131E+01 9.203E-01 6.599E+00 1.448E-01 4.302E+01 Sn119m 5.096E-09 1.204E-10 0.000E+00 0.000E+00 0.000E+00 0.000E+00 1.458E-09 Sn123 1.639E+01 4.035E-01 5.814E+00 1.373E-01 1.691E+00 3.866E-02 4.482E+00 Sn12665 1.253E+03 3.070E+01 4.627E+02 1.069E+01 1.162E+02 2.515E+00 3.444E+02 Sr85 4.302E+02 1.055E+01 1.525E+02 3.478E+00 3.565E+01 7.650E-01 1.181E+02 Sr89 1.234E+01 2.956E-01 3.337E+00 7.516E-02 6.676E-01 1.457E-02 3.396E+00 Sr9066 3.583E+01 8.697E-01 1.119E+01 2.577E-01 2.715E+00 6.060E-02 9.839E+00 Ta182 1.119E+03 2.880E+01 5.501E+02 1.360E+01 2.072E+02 4.866E+00 3.024E+02 Tb157 8.867E-08 2.095E-09 0.000E+00 0.000E+00 0.000E+00 0.000E+00 2.537E-08 Tb160 9.230E+02 2.347E+01 4.186E+02 1.015E+01 1.421E+02 3.276E+00 2.512E+02 Tc97m 2.362E-04 5.528E-06 3.075E-07 6.408E-09 0.000E+00 0.000E+00 6.408E-05 Tc99 5.142E-02 1.198E-03 5.833E-03 1.240E-04 3.524E-04 7.209E-06 1.405E-02 Tc99m 3.249E+01 7.570E-01 3.306E+00 7.021E-02 1.518E-01 2.948E-03 8.864E+00 Te121 4.456E+02 1.092E+01 1.578E+02 3.597E+00 3.682E+01 7.901E-01 1.223E+02 Te121m 1.332E+02 3.168E+00 3.473E+01 7.813E-01 7.314E+00 1.675E-01 3.669E+01 Te123m 3.067E+01 7.147E-01 3.121E+00 6.629E-02 1.433E-01 2.783E-03 8.369E+00 Te125m 1.022E-01 2.381E-03 1.040E-02 2.208E-04 4.775E-04 9.270E-06 2.788E-02 Te127 5.022E+00 1.199E-01 1.410E+00 3.133E-02 2.602E-01 5.495E-03 1.384E+00 64 Includes daughter In113m.

65 Includes daughter Sb126m.

66 Includes daughter Y90.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-16 Table 7.5-2 - OPTIMUS-L SIA Configuration Dose Rate/Ci Results (9 Pages)

Isotope No SIA NCT Dose Rate (mrem/hr/Ci) 1-inch SIA NCT Dose Rate (mrem/hr/Ci) 21/4-inch SIA NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Pkg Surface 2-meter Pkg Surface 2-meter Pkg Surface 2-meter 1-meter Te127m67 4.979E+00 1.190E-01 1.405E+00 3.124E-02 2.612E-01 5.519E-03 1.372E+00 Te129 5.352E+01 1.300E+00 1.788E+01 4.093E-01 4.283E+00 9.405E-02 1.470E+01 Te129m68 5.985E+01 1.464E+00 2.138E+01 4.937E-01 5.424E+00 1.191E-01 1.643E+01 Th227 8.045E+01 1.888E+00 1.767E+01 3.816E-01 2.279E+00 5.014E-02 2.227E+01 Th22869 1.257E+03 3.303E+01 6.757E+02 1.747E+01 3.148E+02 8.025E+00 3.332E+02 Th229 1.497E+01 3.489E-01 2.169E+00 4.611E-02 1.909E-01 4.095E-03 4.108E+00 Th230 3.897E-02 9.107E-04 6.890E-03 1.503E-04 1.816E-03 4.177E-05 1.069E-02 Th231 5.624E-01 1.311E-02 6.518E-02 1.386E-03 4.217E-03 8.712E-05 1.538E-01 Th232 8.745E-03 2.050E-04 1.530E-03 3.440E-05 6.697E-04 1.565E-05 2.387E-03 Th23470 4.400E+01 1.089E+00 1.633E+01 3.868E-01 4.851E+00 1.111E-01 1.203E+01 Tl206 3.784E-02 9.565E-04 1.647E-02 3.923E-04 5.127E-03 1.153E-04 1.034E-02 Tm168 9.607E+02 2.406E+01 3.944E+02 9.321E+00 1.171E+02 2.621E+00 2.627E+02 Tm170 2.926E+00 6.919E-02 6.411E-01 1.411E-02 9.868E-02 2.129E-03 8.059E-01 Tm171 7.424E-07 1.743E-08 6.396E-10 1.334E-11 1.306E-12 2.535E-14 2.054E-07 U232 3.991E-02 9.380E-04 7.782E-03 1.736E-04 2.639E-03 6.088E-05 1.094E-02 U233 7.298E-02 1.721E-03 1.681E-02 3.700E-04 3.521E-03 7.952E-05 2.015E-02 U234 1.751E-02 4.111E-04 3.327E-03 7.516E-05 1.561E-03 3.635E-05 4.780E-03 U23571 3.800E+01 8.855E-01 4.751E+00 1.009E-01 3.371E-01 7.072E-03 1.040E+01 U236 8.760E-03 2.067E-04 2.213E-03 5.091E-05 1.337E-03 3.134E-05 2.394E-03 U238 1.389E-01 3.462E-03 1.267E-01 3.040E-03 1.107E-01 2.621E-03 3.994E-02 U239 1.365E+01 3.354E-01 4.745E+00 1.105E-01 1.253E+00 2.788E-02 3.744E+00 W181 4.166E-02 9.707E-04 4.237E-03 9.000E-05 1.946E-04 3.778E-06 1.137E-02 67 Includes daughter Te127.

68 Includes daughter Te129.

69 Includes daughters Ra224, Rn220, Po216, Pb212, Bi212, Tl208, and Po212.

70 Includes daughters Pa234m and Pa234.

71 Includes daughter Th231.

OPTIMUS-L Package SAR December 2023 Docket No. 71-9390 Revision 23D NAC International 7.5-17 Table 7.5-2 - OPTIMUS-L SIA Configuration Dose Rate/Ci Results (9 Pages)

Isotope No SIA NCT Dose Rate (mrem/hr/Ci) 1-inch SIA NCT Dose Rate (mrem/hr/Ci) 21/4-inch SIA NCT Dose Rate (mrem/hr/Ci)

HAC Dose Rate (mrem/hr/Ci)

Pkg Surface 2-meter Pkg Surface 2-meter Pkg Surface 2-meter 1-meter W185 2.352E-01 5.493E-03 3.380E-02 7.240E-04 3.064E-03 6.555E-05 6.451E-02 W18872 5.802E+01 1.424E+00 1.979E+01 4.648E-01 5.501E+00 1.248E-01 1.587E+01 Xe127 1.401E+02 3.287E+00 2.976E+01 6.427E-01 3.760E+00 8.257E-02 3.875E+01 Xe131m 7.087E-01 1.651E-02 7.210E-02 1.532E-03 3.312E-03 6.429E-05 1.933E-01 Y88 2.421E+03 6.348E+01 1.295E+03 3.282E+01 5.534E+02 1.357E+01 6.482E+02 Y89m 8.392E+02 2.140E+01 3.841E+02 9.302E+00 1.277E+02 2.929E+00 2.287E+02 Y90 3.507E+01 8.519E-01 1.106E+01 2.549E-01 2.700E+00 6.028E-02 9.630E+00 Y90m 4.376E+02 1.043E+01 1.242E+02 2.746E+00 2.261E+01 4.777E-01 1.207E+02 Y91 1.636E+01 3.984E-01 5.199E+00 1.210E-01 1.347E+00 3.053E-02 4.485E+00 Zn65 5.307E+02 1.362E+01 2.594E+02 6.365E+00 9.514E+01 2.216E+00 1.437E+02 Zr88 2.301E+02 5.489E+00 6.151E+01 1.371E+00 9.865E+00 2.164E-01 6.377E+01 Zr90m 2.102E+03 5.655E+01 1.264E+03 3.307E+01 6.272E+02 1.589E+01 5.524E+02 Zr93 7.448E-11 1.760E-12 0.000E+00 0.000E+00 0.000E+00 0.000E+00 2.131E-11 Zr9573 6.428E+02 1.608E+01 2.660E+02 6.242E+00 7.683E+01 1.704E+00 1.759E+02 72 Includes daughter Re188.

73 Includes daughter Nb95m.