Text

From:

Sent:

To:

Subject:

Ryan, Domenico Luongo Tue, 1 Aug 2023 10:30:15 -0400 Ryan Craffey

[External_Sender] Re: Oakland University is rescheduled for - August 2nd The start time is 8am tomorrow. Same check-in procedmes as last time.

Domenic On Tue, Aug 1, 2023 at 8:49 AM Ryan Craffey <Ryan.Craffey@nrc.gov> wrote:

Morning Domenic, Hope preparations are going well. What's the planned start time for tomorrow?

See you then, Ryan From: Domenico Luongo <luongo@oakland.edu>

Sent: Friday, June 16, 2023 3:01 PM To: Ryan Craffey <Ryan.Craffey@nrc.gov>

Subject:

[Extemal_Sender] Oakland University is rescheduled for - August 2nd

Ryan, Our new reload date is scheduled for August 2nd. JLS confirmed today.

Domenic Domenico Luongo, MSc, CHMM Director - Research Compliance and Integrity, BSO & RSO

Oakland University The Research Office West Wilson Hall, Room 530 371 Wilson Blvd.

Rochester, Ml 48309-4486 Tel: (248) 370-4314 Fax: (248) 370-2973 https://www.oak.land.edu/labsafety/

Domenico Luongo, MSc, CHMM Director - Research Compliance and Integrity, BSO & RSO Oakland University The Research Office West Wilson Hall, Room 530 371 Wilson Blvd.

Rochester, Ml 48309-4486 Tel: (248) 370-4314 Fax: (248) 370-2973 https://www.oakland.edu/labsafety/

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (AMENDED IN ITS ENTIRETY)

NO.: CA-0598-S-122-S DA TE: 24 May 2022 PAGE l of6 SOURCE TYPE: Gamma Source MODEL:

DISTRIBUTOR:

MANUFACTURER:

ISOTOPE:

Cobalt-60 LEAK TEST FREQUENCY:

7810 J. L. Shepherd and Associates 10 IO Arroyo A venue San F emando, CA 91340-1822 General Electric Company, Nuclear Center P. 0. Box 460, Pleasanton, CA 94566 Westinghouse Hanford P.O. Box 1970, Richland, WA 49352 Oak Ridge National Laboratory Note: (Old mfr.)

Bldg. 3037, Oak Ridge, TN 37830 C. E. A. Department Des Radioelements B.P.No. 2, 91 Gif-Sur-Yvette, France Amersham International Distributed by Amersham Corp.

2536 South Clearbrook Drive Arlington Heights, IL 60005 MAC Isotopes, LLC (1995 to April 1998) 2325 West Broadway, Suite D Idaho Falls, ID 83402 Nordion International, Inc. (Formerly Atomic Energy of Canada, Ltd. Or AECL)

P.O.Box 13500 447 March Road Kanata, Ontario, Canada K2K I X8 Isotope Products Laboratories 24937 Ave Tibbitts, Valencia, CA 91355 Isotope Products Laboratories 1811 N Keystone Street, Burbank, CA 91504 MAXIMUM ACTIVITY:

Six (6) Months

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (AMENDED IN ITS ENTIRETY)

NO.: CA-0598-S-122-S DA TE: 24 May 2022 PAGE2 of6 SOURCE TYPE: Gamma Source PRINCIPAL USE:

CUSTOM SOURCE:

__ YES X

NO

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (AMENDED IN ITS ENTIRETY)

NO.: CA-0598-S-122-S DA TE: 24 May 2022 PAGE 3 of6 SOURCE TYPE: Gamma Source DESCRIPTION:

The Model 7810 source capsules are designated to be used inkb)(7)(F)

~---__!,======================,----~

facilities. Sources used in free air calibration will bel(b )(7)(F)

I and can be independent of a device other than a storage shield. Generally the em ca sules are fabricated from stainless steel at the distributor's facility and shipped to an encapsulator..,_b_)...,_(_7"'"')(~F..... ) ________

~

where they are loaded with radioactive material (typically provided by a national laboratory), doubly encapsulated and sealed b heliarc weldin. "S ecial Form" certification is issued b the com any that provides the capsule body (b)(7)(F)

Note:

Older sealed sources were encapsulated by ORNL, Brookhaven National Lab or other national laboratories and the reviewer may encounter some of these sources.

There are three source categories based on physical dimensions and quantity of radioactivity in the source capsule. The basic categories are listed below in Table 1. A source holder is provided (Attachment 2) that is machined to fit each category of capsule. Each source holder is designed to have al(b)(7)(F) I Kb)(7)(F)

I These sources should be used in the J. L. Shepherd and Associates devices and/or shielding containers with a source holder that is of compatible size to the source.

Table 1 Source Categories:

,b)(7)(F)

Sources greater._l(b_)_(_7_)(_F_) ______ _.I are considered to be custom sources and must have an independent evaluation.

LABELING:

Each capsule is typically etched with the following information: isotope, serial number, activity, and date.

The sources containing large curie quantities are normally in heavily shielded devices bearing a label revealing the type, quantity of radioactive material and serial number. Low-curie sources designed to be handled outside of devices are normally fixed in a holder that provides the additional information ( date, source type, activity level).

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (AMENDED IN ITS ENTIRETY)

NO.: CA-0598-S-122-S DA TE: 24 May 2022 SOURCE TYPE: Gamma Source DIAGRAMS:

Refer to Attachments I and 2. : Typical features of all source capsules. : Source Holder.

CONDITIONS OF NORMAL USE:

PAGE4 of6 These sources are designed to be used in J. L. Shepherd and Associates, ""'l(b=-<).:....:(7_._)('"'"F...,_) _______ __.

~here a standard size source holder is used. Sources and devices in tum are designed for use under standard laboratory conditions: temperature range 10--50 °C, non-corrosive atmospheres and vibration levels associated with nonnal laboratories.

PROTOTYPE TESTING:

Prototype sources have been tested and certified to meet "Special Form" requirements according to 49 CFR 173.469 and designated as having an ANSI classification of ANSI 77E43424.

A record of production of these types of sources has been established over at least 20 years with no reported breach of source integrity.

EXTERNAL RADIATION LEVELS:

(b )(7)(F)

QUALITY ASSURANCE AND CONTROL:

All capsule bodies are constructed in accordance with J. L. Shepherd and Associates Quality Control Manual QA-RM-001-A, which covers engineering design through final fabrication approval. Quality Control of source encapsulation is also controlled by the manufacturer's Quality Assurance Programs.

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (AMENDED IN ITS ENTIRETY)

NO.: CA-0598-S-122-S DA TE: 24 May 2022 PAGE 5 of6 SOURCE TYPE: Gamma Source LIMIT A TIO NS AND/OR OTHER CONSIDERATIONS OF USE:

A.

The source shall be distributed only to specific licensees of the U.S. NRC or an Agreement State.

B.

Handling, storage, use, transfer, and disposal: To be determined by the licensing authority.

C.

The source shall be tested for leakage and/or contamination at intervals not to exceed six (6) months. Such tests shall be done by qualified inclividuals and shall be capable of detecting 0.005

µ.Ci (185 Bq) of removable radioactive material.

D.

Kb)(?)(F)

E.

The source is designed for use in J. L. Shepherd and Associates source holders and devices. The source (which meets Table 1 source categories) may also be used as replacement sources for reloading l(b)(?)(F) lwhlch have not been manufactured by J. L.

Shepherd and Associates, provided that such modified device is authorized by the Nuclear Regulatory Commission or an Agreement State.

F.

The source shall be used only in a laboratory environment of non-corrosive atmosphere and normal temperatures.

G.

Reviewer's Note: The purpose of this amendment dated, 24 May 2022, is to add Isotope Products Laboratories as a manufacturer.

H.

This registration sheet and the info1mation contained within the references shall not be changed without the written consent of the California Department of Public Health.

SAFETY ANALYSIS

SUMMARY

Based on the review of Model 7810, its ANSI classification, and the information and data contained in references listed below, we continue to conclude that the sealed source is acceptable for licensing purposes.

Furthermore, we continue to conclude that the source would be expected to maintain its containment integrity for normal conditions of use and accidental conditions, which might occur during uses specified in this certificate.

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (AMENDED IN JTS ENTIRETY)

NO.: CA-0598-S-122-S DA TE: 24 May 2022 PAGE 6 of6 SOURCE TYPE: Gamma Source

REFERENCES:

Application for Radiation Safety Evaluation and Registration of Sealed Source; J. L. Shepherd and Associates, March 2, 1989, with letters modifying application dated June 15, 1989, and September 15, 1989, signed by J. L. Shepherd.

J. L. Shepherd and Associates, California Radioactive Material License Number I 777-70.

J. L. Shepherd and Associates Quality Control Manual Q.A.-RM-001-A.

J. L. Shepherd and Associates letters dated December 6, 1996, and May 20, 1997, with attachments, thereto.

J. L. Shepherd and Associates letters dated January 20, 1999, and August 9, 2004, with attachments thereto, signed by Mary F. Shepherd.

J. L. Shepherd and Associates letter dated December 8, 2015, and email dated August 10, 2018.

J. L. Shepherd and Associates letter dated March 4, 2022, signed by Mary F. Shepherd.

ISSUING AGENCY: California Department of Public Health DA TE: -=M=a=--y'--'2=--4=*=20=2=2'----

Reviewer:

Frank Spinardi DA TE:

May 24, 2022 AIJ"n

/J Concurrence:

~~

-~o+--K-r-is-tin_a_D~e ~L-eo_n __ _

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (AMENDED IN ITS ENTIRETY)

NO.: CA-0598-S-122-S DATE: 24 May 2022 ATTACHMENT l OF 2 b)(7)(F)

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (AMENDED IN ITS ENTIRETY)

NO.: CA-0598-S-122-S DA TE: 24 May 2022 ATTACHMENT 2 OF 2 (b )(?)(F)