Analysis of Public Comments on Draft DANU-ISG-2022-04, Advanced Reactor Content of Application Project Chapter 10, Control of Occupational DoseML23277A151 |
Person / Time |
---|
Issue date: |
03/25/2024 |
---|
From: |
NRC/NRR/DANU/UARP |
---|
To: |
|
---|
Shared Package |
---|
ML23277A105 |
List: |
---|
References |
---|
DANU-ISG-2022-04, NRC-2022-0077, ML23277A105 |
Download: ML23277A151 (2) |
|
|
---|
Category:Graphics incl Charts and Tables
MONTHYEARML23277A1552024-03-31031 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-08, Advanced Reactor Content of Application Project, Risk-Informed Technical Specifications ML23277A1562024-03-25025 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-09, Advanced Reactor Content of Application Project, Risk-informed, Performance-based Fire Protection Program (for Operations) ML23277A1522024-03-25025 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-05, Advanced Reactor Content of Application Project Chapter 11, Organization and Human-System Considerations ML23277A1482024-03-25025 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-01, Advanced Reactor Content of Application Project, Review of Risk-Informed, Technology-Inclusive Advanced Reactor Applications - Roadmap ML23277A1512024-03-25025 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-04, Advanced Reactor Content of Application Project Chapter 10, Control of Occupational Dose ML23277A1492024-03-25025 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-02, Advanced Reactor Content of Application Project Chapter 2, Site Information ML23277A1542024-03-25025 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-07, Advanced Reactor Content of Application Project, Risk-Informed Inservice Inspection/Inservice Testing ML23059A5132023-03-0101 March 2023 Table 1 – Responses to NEI Comments on Predecisional Draft Guide ML22276A149 ML21308A6152021-11-0404 November 2021 Advanced Reactor Program - Summary of Integrated Schedule and Regulatory Activities ML20112F5082020-04-16016 April 2020 2020-04-15 Summary Table of Proposed Safety Evaluation Changes 4015 2024-03-31
[Table view]Some use of "" in your query was not closed by a matching "". Category:Guidance Document
MONTHYEARML23277A1462024-03-31031 March 2024 Interim Staff Guidance - DANU-ISG-2022-08, Advanced Reactor Content of Application Project, Risk-Informed Technical Specifications ML23297A1642024-03-31031 March 2024 Redline Strikeout for Interim Staff Guidance - DANU-ISG-2022-07, Advanced Reactor Content of Application Project, Risk-Informed Inservice Inspection/Inservice Testing ML23297A1662024-03-31031 March 2024 Redline Strikeout for Interim Staff Guidance - DANU-ISG-2022-09, Advanced Reactor Content of Application Project, Risk-informed, Performance-based Fire Protection Program (for Operations) ML23277A1552024-03-31031 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-08, Advanced Reactor Content of Application Project, Risk-Informed Technical Specifications ML23297A1652024-03-31031 March 2024 Redline Strikeout for Interim Staff Guidance - DANU-ISG-2022-08, Advanced Reactor Content of Application Project, Risk-Informed Technical Specifications ML23277A1452024-03-31031 March 2024 Interim Staff Guidance - DANU-ISG-2022-07, Advanced Reactor Content of Application Project, Risk-Informed Inservice Inspection/Inservice Testing ML23277A1432024-03-31031 March 2024 Interim Staff Guidance - DANU-ISG-2022-05, Advanced Reactor Content of Application Project Chapter 11, Organization and Human-System Considerations ML23277A1422024-03-31031 March 2024 Interim Staff Guidance - DANU-ISG-2022-04, Advanced Reactor Content of Application Project Chapter 10, Control of Occupational Dose ML23277A1402024-03-31031 March 2024 Interim Staff Guidance - DANU-ISG-2022-02, Advanced Reactor Content of Application Project Chapter 2, Site Information ML23277A1472024-03-31031 March 2024 Interim Staff Guidance - DANU-ISG-2022-09, Advanced Reactor Content of Application Project, Risk-informed, Performance-based Fire Protection Program (for Operations) ML23277A1442024-03-31031 March 2024 Interim Staff Guidance - DANU-ISG-2022-06, Advanced Reactor Content of Application Project Chapter 12, Post-manufacturing and Construction Inspection, Testing, and Analysis Program ML23277A1412024-03-31031 March 2024 Interim Staff Guidance - DANU-ISG-2022-03, Advanced Reactor Content of Application Project Chapter 9, Control of Routine Plant Radioactive Effluents, Plant Contamination and Solid Waste ML23297A1622024-03-31031 March 2024 Redline Strikeout for Interim Staff Guidance - DANU-ISG-2022-05, Advanced Reactor Content of Application Project Chapter 11, Organization and Human-System Considerations ML23277A1392024-03-31031 March 2024 Interim Staff Guidance - DANU-ISG-2022-01, Advanced Reactor Content of Application Project, Review of Risk-Informed, Technology-Inclusive Advanced Reactor Applications - Roadmap ML23297A1612024-03-31031 March 2024 Redline Strikeout for Interim Staff Guidance - DANU-ISG-2022-04, Advanced Reactor Content of Application Project Chapter 10, Control of Occupational Dose ML23297A1602024-03-31031 March 2024 Redline Strikeout for Interim Staff Guidance - DANU-ISG-2022-03, Advanced Reactor Content of Application Project Chapter 9, Control of Routine Plant Radioactive Effluents, Plant Contamination and Solid Waste ML23297A1592024-03-31031 March 2024 Redline Strikeout for Interim Staff Guidance - DANU-ISG-2022-02, Advanced Reactor Content of Application Project Chapter 2, Site Information ML23297A1582024-03-31031 March 2024 Redline Strikeout for Interim Staff Guidance - DANU-ISG-2022-01, Advanced Reactor Content of Application Project, Review of Risk-Informed, Technology-Inclusive Advanced Reactor Applications - Roadmap ML23277A1482024-03-25025 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-01, Advanced Reactor Content of Application Project, Review of Risk-Informed, Technology-Inclusive Advanced Reactor Applications - Roadmap ML23277A1532024-03-25025 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-06, Advanced Reactor Content of Application Project Chapter 12, Post-construction Inspection, Testing, and Analysis Program ML23277A1522024-03-25025 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-05, Advanced Reactor Content of Application Project Chapter 11, Organization and Human-System Considerations ML23277A1502024-03-25025 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-03, Advanced Reactor Content of Application Project Chapter 9, Control of Routine Plant Radioactive Effluents, Plant Contamination and Solid Waste ML23277A1492024-03-25025 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-02, Advanced Reactor Content of Application Project Chapter 2, Site Information ML23297A1632024-03-25025 March 2024 Redline Strikeout for Interim Staff Guidance - DANU-ISG-2022-06, Advanced Reactor Content of Application Project Chapter 12, Post-manufacturing and Construction Inspection, Testing, and Analysis Program ML23277A1562024-03-25025 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-09, Advanced Reactor Content of Application Project, Risk-informed, Performance-based Fire Protection Program (for Operations) ML23277A1512024-03-25025 March 2024 Analysis of Public Comments on Draft DANU-ISG-2022-04, Advanced Reactor Content of Application Project Chapter 10, Control of Occupational Dose ML23188A1782023-12-31031 December 2023 Interim Staff Guidance - DANU-ISG-2023-01, Material Compatibility for Non-Light Water Reactors ML23234A2332023-08-15015 August 2023 DANU-ISG-2021-01 Material Compatibility for Non-Light Water Reactors Interim Staff Guidance for ACRS Review ML22048B5492023-05-31031 May 2023 Draft Interim Staff Guidance - DANU-ISG-2022-07, Advanced Reactor Content of Application Project, Risk-Informed Inservice Inspection/Inservice Testing ML22048B5412023-05-31031 May 2023 Draft Interim Staff Guidance - DANU-ISG-2022-02, Advanced Reactor Content of Application Project Chapter 2, Site Information ML22048B5472023-05-15015 May 2023 Draft Interim Staff Guidance- DANU-ISG-2022-09, Advanced Reactor Content of Application Project, Risk-informed, Performance-based Fire Protection Program (for Operations) ML22048B5442023-05-15015 May 2023 Draft Interim Staff Guidance - DANU-ISG-2022-04, Advanced Reactor Content of Application Project Chapter 10, Control of Occupational Dose ML22048B5432023-05-15015 May 2023 Draft Interim Staff Guidance - DANU-ISG-2022-03, Advanced Reactor Content of Application Project Chapter 9, Control of Routine Plant Radioactive Effluents, Plant Contamination and Solid Waste ML22203A1752023-02-28028 February 2023 Draft Interim Staff Guidance - Material Compatibility for non-Light Water Reactors (DANU-ISG-2023-01) ML21011A1402021-02-26026 February 2021 Design Review Guide (Drg): Instrumentation and Controls for Non-LWR Reviews 2024-03-31
[Table view]Some use of "" in your query was not closed by a matching "". |
Text
1 Analysis of Public Comments on Draft DANU-ISG-2022-04 Advanced Reactor Content of Application Project Chapter 10, Control of Occupational Dose Comments on the draft interim staff guidance (ISG) are available electronically at http://www.nrc.gov/reading-rm/adams.html. From this page, the public can access the Agencywide Documents Access and Management System (ADAMS), which provides text and image files of the U. S. Nuclear Regulatory Commission (NRC) public documents. The following table lists the comments the NRC received on the draft ISG.
Comment Number ADAMS Accession Number Commenter Affiliation Commenter Name NRC-2022-0074-DRAFT-0006 ML23229A120 Nuclear Energy Institute Ben Holtzman Commenter Identifier Topics Section of Document Specific Comment NRC Staff Response RC-2022 0074-DRAFT-0006-1 General General Please rephrase to indicate the guidance is technology-inclusive and is equally applicable to both LWR and non-LWR designs.
Throughout all the documents of the package, there are statements that this guidance is applicable to nonLight Water Reactors (LWRs). However, all the guidance is technology-inclusive and is equally applicable to LWRs.
ARCAP is supposed to be applicable for any technology (non-LWR and LWR), any licensing approach (LMP, classical, etc.), and any licensing path (CP, COL, DC etc.).
For the ARCAP guidance, industry specifically requested the NRC develop guidance applicable to both non-LWRs and LWR SMRs, and we were informed in various meetings that this would be the NRCs approach. While NEI 18-04 and NEI 21-07 were developed specifically for advanced non-LWRs, applicants with LWR designs should also be able to use the Licensing Modernization Project (LMP) methodology if they elect to do so (e.g., NEI 18-04 and NEI 21-07). It would be up to the applicants to justify the use of the guidance documents and associated regulatory guides.
The NRC staff disagrees with the comment.
The NRC staff is considering expanding the applicability of ARCAP guidance documents beyond non-light water reactors (non-LWRs).
However, expansion of the guidance beyond non-LWRs at this time is considered premature.
The final ISG continues to note that the NRC is developing an optional performance-based, technology-inclusive regulatory framework for licensing nuclear power plants designated as 10 CFR Part 53, Licensing and Regulation of Advanced Nuclear Reactors, (RIN 3150-AK31). If the NRC promulgates a final 10 CFR Part 53 rule, the NRC staff plans to apply the 10 CFR Part 53 guidance to both LWRs and non-LWRs. Should the 10 CFR Part 53 rulemaking include requirements for both LWR and non-LWRs, the NRC staff envisions that the guidance documents supporting that rulemaking would provide a basis to expand the concepts found in the ARCAP ISGs guidance beyond non-LWRs. In the interim, the NRC staff notes that the applicability section of the ISG notes that applicants desiring to use the ISG for a light water reactor application should contact the NRC staff to hold pre-application discussions on their proposed approach.
No change to this ISG.
2 Commenter Identifier Topics Section of Document Specific Comment NRC Staff Response NRC-2022-0074 DRAFT -
14 As low as reasonably achievable ARCAP Roadmap ISG and ARCAP ISG Chapter 10 The following comment was submitted on the ARCAP roadmap ISG regarding ALARA. The specific comment is; The wording on ALARA in Chapter 10 indicates that the guidance will continue the well-established operational program for ALARA but not extend ALARA into the design, as a regulatory requirement. Industry agrees with this position as it provides a predictable regulatory framework.
The NRC staff disagrees with the comments characterization of the guidance in ISG Chapter 10. The guidance references design elements to control occupational exposures in several instances and includes the following acceptance criteria:
Describe important equipment and facility design features that satisfy the design-specific PDC necessary to control occupational exposure, including ensuring occupational radiation exposures are ALARA, such as shielding, ventilation, area radiation and airborne radioactivity monitoring instrumentation, and dose assessment for expected occupancy.
To further clarify the relationship between radiation protection programs and DANU-ISG-2022-04, the staff added reference to NEI 07-03A, Generic FSAR Template Guidance for Radiation Protection Program Description, which should be used in conjunction with the template in NEI-07-08A, Generic FSAR Template Guidance for Ensuring that Occupational Radiation Exposures are as Low as is Reasonably Achievable (ALARA), which is referenced in this ISG.
The NEI templates and related NRC safety evaluations discuss the relationships between various design features, some of which might be in a design-centered application (e.g., design certification) and some of which might be deferred to a combined license application, and programmatic controls developed for plant operations.