{{#Wiki_filter:A B C D 30 B 3 1B 32B 33B 34B 35 B 36B 37 B RV - 274 S2-4486-1 G-0283 r------C::::;J-----'----{;::::::;J---¢----!;::::;J----,-,------.. -----c:0,-----,t-H-] HOSE CONNECT JON DC 60 I 1476-220
- - 1-1 I IP RV 385 NOTE 8 Al R COMPRE SSOR 2 - 3B DC 6011476-226 AIR INTAKE FRON ENGINE GE N.
ROON 2 -3 A DC 6011476-220
- - I - I! I P RV - 386 NOTE 8
- :'.I--
w* A I R COMPRESSOR 2 - 3A DC 6011476 -2 26 D AIR INTAKE FRON ENGINE GEN. ROON TO UNLOADER TO UNLOADER ~ ~ SILENCER NE RV -275 N.C. SILENCER NE G- 0283 S2-4485-1 AIR DR YE R 2 - 3B DC 60 I 14 76-32 1 G-0283 A l '°* S2-449 I - I A IR DRY ER 2-3A DC 60 I 14 76 - 32 1 G-0283 SI LENCER SW S I LE NCER ~ SW 1/2*; I ' (CAPPED. THREADED CONNECT IO N) (NO TE 12l S2-4486-1 S2-4492-I 's2 4493 - 1 1206 ~ ~ S2 -1 NOTE 14 Al 11 42 dQ:,. AFTER F I LTER DC 663082 -1 20 K2- -1/4 K2-3/4 [APS4l APS SPARE OUTLET N~;E 2 - 3A ~ 1 1/2" DC 6011476-203 KN'4 7 r;7 "' C NOTE w 13 STA R TING AI R SYSTEM 2 - 3 RE FER ENCE MFR. OWG. OC - 6O 1 14 76 - 469 Pl [SAPGJ 640 NOTE 6 J o [APSI] PS LOA 165M-A 34 222 NOTE 6 [SAPGJ Pl 641 NOTE 6 s-3/4
- - 11/2 db UN IT SV-498 2
10- 10-2011 AJFJ RxG2 KERS I J. DALAL MECHANICAL N 16690 3/3 1/2 012 REVISED PER DFT - 7.,1 303 r-~o~,~-~[ --~w,-+~R~[-+-~: v---+-P~R~O~CC~S~S~I O~',-A-L ~[~N~G~I N~,~,R~+-,P~E~J I~s~,-, -+-~P~E.--+-~P~[~[~X~P-, --, 38B 39 B NOT ES : I.
- DENOTES MANUFACTURER SUPPLIED INSTRUMENTS & EQUI PMENT.
I T 1S ACCEPTABLE TO REPLACE MANUFACTURER SUPPL I ED INSTRUMENT TUBING WJ TH PG&E SUPPLIED S-SPEC STAINLESS STEE L TUBING
- 2. FIELD PIPING ON THIS SYSTEM SHAL L BE PG&E CLASS IT]
UNLESS OTHERWISE NOTED 3, [ l MANUFACTURER NUMBER ~- MANUAL VALVES PER DWG 6006~73-~0, SIC 93-68~9~
- 5. PRESS URE REDUCING VALVE PROVIDED WI TH STRA INER~
- 6. MOUNTED ON ENGINE CONTROL PANEL~
7, STARTING AIR SOLENOID VA L VES AIR EQU IPPED WITH AN ENERGENCYNANUALOPENINGDEVICE~ 8, FIBERGLASS BLANKET TYPE PERSONNEL I NSULA TION, IN SULATE VENDOR PIPING FROM COMPRESSOR OUTLET TO THE COOLER INLET.~
- 9. K2 SPEC PIPN G TO BE THREADED TO ACCOMOOATE BRONZE SOFT SEAT VALVES.~
- 10. ORJFICED SLIDER SHOWN IN POSITION CONTROLLING FLOWRATE FOR DRYER REGENERATION. ~
- 11. N.O. AIR TO CLOSE; N.C. AIR TO OPEN~
12, BE
- 13. GATE VALVES PER DWG 6006473-166, S/C 93-684 1 ~
CHECK VALVES PER OWG 6006473 - 169, SIC 94 - 3815~ 15.GATEVALVESPERDWG6006473-39, SIC93-6840~ DIESEL EN GI NE 2-3 DC 60 I 1476 43
- -3/s DI ABLO CANYON POWER PLANT -
PG& E CO. DIESEL ENGINE-GENERATOR ASSOCIATED SYSTEMS DRAW i NG SHEET PAGE REV 10802 1 3B 0 42 A B C D E}}