E D

C N B 0

N I

0 I

N 0

z Q) 0

+-

0 O

,Z o

<r:0 w

(j)

-<I:::J N lD Q:

o (J)z N -~

oN,,

0 L

11 N

Q) o::: O U) w

J f-11 en z o

<t D <t o:::ou I NPG I C I Size 60A 61A 62A 63A E

F 3/8 11 4) TIJBI tJG G

]

(:

FROt<I FILTER TO r.l r.,

F.O. DA.Y J

BOOSTER TAtJK DRAIN PUMP

/\

I dL Ff(:.Ot,.1 SV-713 t.:J L!J H

ITe.M D/61-1 DIG t-2 A

WHITE"t' CO.

WHITEY CLJ.

L.:.J SS-NTRF -A 55*31JTRF4-A 8

45V-3 45V-3 C

45V-1 4-SV-:3 0

45V-3 4.SY-1 E

F G

H 4SV-1 l:

45\/-3 4SV-.3 J

~~-A P:t.5-1022.

UN IT I

DEG FUEL OIL FILTER CONFIGURATION EA ST PRIMARY FILTER VENT EAST PRIMAR Y FILTER DRAIN DEG I - I VALVE (D EG-I -354 ) & PLUG VALVE (DEG-1-358 ) & PLUG DEG I -2 VALVE (DEG-1-362) & BLEEDER VALVE (DEG-1-366 ) & BLEEDER DEG I -3 VALVE (D EG-I -37 0) & PLUG VALVE (DEG-1-374 ) & PLUG WEST PRIMARY FILTER VENT WEST PRIMAR Y FILTER DRAIN DEG I - I VALVE (D EG-I -355 ) & PLUG VALVE (DEG-1-359) & PLUG DEG I -2 VALVE (D EG-I -363 l & BLEEDER VALVE (DEG-I -367) & BLEEDER DEG I -3 VALVE (DEG -I - 371 l & PLUG VALVE (DEG-1-375 ) & PLUG 64A D

C l.!.J

/\2 dL 65A 66A 67A 68A 69A 6

!/S 11 4' TlJBI ~6 TO FUEL I rJJECT.

1/2.* 4' TU81NG FROWJ BOOSTeR H PUMP TO Pf<IMIJJ6 TAt,.IK ITENI A

C D

E:

F G

H i Pl-82.ct Pl-603 1/~

114) PIPE 3/8 114> TU~ING

/\ I F

E-~----,

dL D

[:

PI-831 Pl-~25 UN IT I

DEG FUEL OIL FILTER CON FIGURATI ON

/\2 EAST SECONDARY FILTER VENT EAST SECONDARY FILTER DRAIN dL DEG I - I VALVE (DEG-1-356 ) & PLUG VALVE ( DEG-I -360 l & PLUG DEG I -2 VALVE (DEG-I -364 l & BLEEDER VALVE ( DEG-I -368 l & PLUG DEG I -3 VALVE (DEG-1-372) & PLUG VALVE ( DEG-I -376 l & PLUG WEST SECONDARY FILTER VENT WEST SECONDARY FILTER DRAIN DEG I - I VA LVE (DEG-1-357 ) & PLUG VALVE ( DEG-I - 36 I l & PLUG DEG I -2 VALVE (DEG-I -365 l & BLEEDER VALVE ( DEG-I -369 l & PLUG DEG I -3 VA LVE (DEG-1-373 ) & PLUG VALVE ( DEG-I -377 l & PLUG UN IT DIABLO CANYON POWER PLANT - PG&E CO.

DIESEL ENGINE-GENERATOR ASSOCIATED SYSTEMS DRAWi NG SHEET PAGE REV 10 202 1 6A 0 4 3 O 2 - O I - 2 O I 2 MN RU F xC 2 KER S I J. DALAL MECH AN I CA L M I 6 6 9 0 3 / 3 I / 2 0 I 2 REV I S ED PER D FT - 7

  • I 4 I 7 - 0

~::.._______.'.D

.1____A'.._T~E:....'.::'.__'_---=----l-~D ~W:..::N ~.::.R'..':::'.E--=--+-1 V-FP=-.:.R

__:__:O~F~E~S'.....'.S:--:I_:::O'.._'.__N:..:::A~L~ E-:-:N---:::-G---:-I -:-:-N-=-E-=-E ::::-R-~P~E=-----;D:::-I;--::S::-;C:::-.-t------;:::;-P-;::::-E-:-tt---t-----;::;-p ;::-E-E

=-
X~P:::;-.-

E D

C B