POTENTIAL INTERLOCK 41,;.ov 6'M'iioR. eus SECT. F A
B---+---.-----
T5/5A 600/5A 50/5A 270C HF8 CIRCUIT BUS DC No.
SECTION IRCU ITN F08HOO 1130 2130
-~so, l l ~R~Hfs TI-R:E ll\\E DIAGRAM f-TIME DELAY RELAYS FOR MOTOR NO. 11 &,. r,/o. l:Z.
125V DC CONTROL SCHEMATIC AM A~:::TER SWITCH ]w USEOA.TUXAT\\ON§!:£4,~
TRANSFER SWITCH 43H~
-13 1166 u~o AT LOCATION ~
~sPllll#lirTV,rN AUXIL I ARY SALT WATER PUMP No. I I, CI RCU IT No. FOSHOO TABLE OF DEVICES Qj DEV ICE No.
FUNCTION RATING MFR.
TYPE AT/OJ'G.No.
REMARKS 2HF82HG6 SlF[ll]NJ[(T[(ljSIIJl.l.LTIMlkGR[l.
SE*lffllA~rf~T§fte~d ~
5Plf/'I(;. RcTL'lf"' 10 /V~uUML POSI T ION CONTACTS SIOPNEUTSTART REMARK S
- = I:
X TH IS OWG
- H-C X
X TH IS OWG
-H-D X
X TH IS OWG
- H-E X
X TH IS OWG
~i=° F
X
'ifi1P.1Pf.-,JYU,-%ff-:~
S/"RIN6 /'f£TVRJ,1 TO JIUJrRAL.
/'W..aALTW"ATER l.DN ~
-_-_1-1-*=**=*:t===t==:t2c=
K61 7 S/IFETY INJECT\\ONINTLK_.""
=
"'-=-~-~~(HJ{J.5~'1)
MODE SELECTOR SWITCH 43HF8d-3HI1/4 LISED ATU)CA.TKlN Bi.
NON SPl?OIG-l<ETUR/1 TI -H-Ml. 1I----H-MI I-H----5, I-H----5
.:E"':,::~
,s a -
sHFs
~
TRAN SF£~ SWITCH ; i/'MIF8, 43HG' 1...oc; '"il!.£1,~
-=rs rs" 120 '-OC SPACE HUTER FOR I-CIT. No.I I - nT.i,o.PJI II O
)[ lol]ll~ FO~ loCJT.-0.I2 BC[~J US[ HT~. LOC. l,!H~, I en. - 0. ~JII Ii EQUIPMENT LOCATION NUMBERS coi.TROL ~OARD.-I.U XILJ.-1.RY S.-I.LHi.-1.TER ( $[CT. IVB I I HOT SHUT oo..-i, RHOT[ CO!,TROL PAH[l I HHFI
.-I.UX! Ll.-1.RY SALT.i.-1.T[R PUMP i,o. I I
~-
!:;~~~~~.~A~~~u :~~SFR~~:~c~~.-1.:0 BUS F RNSO~
i,UCLE.-1.R S.-1.FEGU.-1.RD OUTPUT RAC, -
TRAIN B
~l'i I HSTRUMEHT Ho.PSl~l'iLOCAL"°Ui,TED BTH I I O TERMli,AL BOXAREAHi,o.I I 0
~IPO.i[RPAiol[L ii,UK[STRUCTURE REFERENCES I. OESCRP I T ION OF ELECTR ICAL OIAGRAM,S YMBOLS & CKT. DESIGNA T IONS.
- 2. SINGLELINEMETERtRELAY 4I60VSYSTEMSH. 2 IBUSF,G.H I.
- 3. SCHEMATIC D IAGRAM POTENTIAL t SYNCHRONIZING 4 I60V SYS TEM.
SCH£MATICDIAGRAM4I60VBUSFAUTOMATICTRANSF£R.
SCHEMATICDIAGRAM4I60VBUSGAUTOMATIC TRANSFER 6. SCH[MATI CDI AGR AM4 I60Y BUSOJFFERENTI AL SH. 2.
7. SINGLE LINE METER &RELA Y I25VDCSYS TEM.
- 8. SCH£MATICOIAGRAM4I60VBUSHAUTOMATICTRANSF[R.
EQUIPMENT LOCATION NO.S.
PIPING SCHEMATIC SALT WATER SYSTEM.
II.LOGI CD I AGRAM AU XI LIARYSALTWAT ERPUMPS.
I2.SCHEMATICDIAGRAM MAINANNUNCIATORSH.
I
14.@ FUNCTIOl,D IAGRAM.
15.@SOLIDSTATE PROTECTION SYSTEM.
I 6.SCHENAT ICDIAGRAMMONI TOR LIGHT BOXC.
OWG.
050003 437533 437614 437626 437617 437627 10 1900 10 20 17 19 406 501121 437865 663195 I7. SCH[NAT ICDIAGRA MSSPSOUTPUTRELAYS,TRAINA. TRAINS.
501869,503088 I 8.SCH[NAT!COIAGRAM MAIN ANNUNCIATOR.
437700 I9. P. O.SCONTROLCIRCU ITSSCHENAT I CD IAGRAM OWG.
N0.6009838-69
- 20. SCHEMATIC DIAGRAM VENTILATION FAN MOTORS 437637 NUC LE AR SAFETY RELATED 50 II 38 IBUSFJ 50II37 IBUSG )
,A, KE Y DWG. SECTION _, _
UNIT I P.G.U. SYSH!ol PH.I.SE SEOUE~C[
.1.-C -~
SCHEMATIC DIAGRAM AUXILIARY SALT,,rATERPUMP 437594 33