30 31 32 33 34 35 36 37 38 39 FROM FROM NOTES: CONTINUED F E -64 I A FE-641 B COMl'ONENT (.:/,

~

/7. DEt..CTCO 35 COOL I t.16 WAlt:R RE5f0t./AL FLUSMIN6 IS 5.S SPACER BETWEEN FL A N G E , ~

/.IEAT REMOVAL

  • D S - 1684 -%1~!1 S-- -----------,

~ RETURN E'XC.1-IANGE.R PUMP ROOM I-I CONN~TION 8133.A CKJTSll)E: INSIDE DES IGf-J CLASS 1,PG fk E CLASS e, I~. 1"GATE,s.W~VELAtJ SC,ff~4-..3778 J'4*TS8 1/-.-

s1 -Y.m ,_____

SI tC* 127

  • 12 st-93o-.3m r-------- co,rTA.IMt'1£14l: COMl-'lNt"ENT I

FtEF. DWG. DC-~7~-1~7 ).31- 8 ,D) 20, <oOO# 316 S.5 FLAl\kSES )31*0,C,D)

E I 1

2 1. 1/2 11 GATE, C:RAI-JE- ALOYCO )31-0.c:,D) E HE A ~ V A L 'Jc ~:G~f'P 22 MODEL 114, STOCK COOE 71-~IGZ..

111 4> VENT A55EMBLY W/A!JC:HOR EXCHANGER NOTE.. IS J(-tl  ?AR.UNG MODEL 1878 GLOBE ROOM 1-f i1/zIIIP" VALVE, DC-<oOO<o47.!HE7 ) .3:2.*0.D) 3/4"

~ ~

2 3. A~C HOR OARLIN(i (iLOBE VALVE

) 3ZG* El 32) ('14l*EIJ5 ) ~ (321A 31to( ;~~:~NN~~T $ /C. #')4 - 2.820, DWG DC.-1,,00b473 - 97

~~

L OOP I &2

~ ~

24 . OWG " 60 I 1929-8, SIC 95-5897 CO LD LEG SI-II

@)QH)

NOTf:17 NOTES D<- - CONT. -

8742A BELO ~V r,TV F:,.V 1

1S 1/4-TS8

Js\ S2 SI S2*234f.*1/2aIP E

L:J I SZ- 163!-~4, E~

L---------- ------- --- --'

S I 8

~2- l 167-4MP  :~ti:r~ 1"4 -TSB QUTSIDl D 58 SI P\.1-\P ~  : **1MS1DlM~SsiltBr,tRiER. D SI

  • _ _ ~~fLO.li, RooM

' V BY S1- ).IDP VA L VE 52 - 1634- 3/4 4 30t-Y2. K- lt4 - 14 58 lUOOWN MT E'lCM INLET

~

3/4-TSB S2-4299-3/4.

5UMP ru:m: L~ - 58 M I S C E Q U I p (32 IA-313( Sl - 1662-2ID r---~--B;,~;-

RES/OVAL (fil

-""'""=='- --~~,I=--'-

I 52-4307-~4 33A*l 19 1/4 * ¥4fil C I HEAT RE.MOVAL ClOSED 3/4, -TS., C DRAIN TC Nl7TC/2 S2- 234?-YtillP R. c.o. T.

3/4*TS.!' {A@ CLDSE.D DRAIN irn- R, .C . . T.

(32. jA- 317( S 2*515D *\ 33A*£ 19

~ CON TI NUED E

F.O ~~ ~ :~ 25 . INSULATION ON PORT I ONS OF THESE LINES HA VE ADDI TION A L BANDS INSTA L LED ON 3 "

OT foU) CENTER - TO - CENTER (MAXI SPAC I NG . SE E DWGS 224757 AND 447 11 2 FOR SPEC I F I C LOCAT IONS .

26. ELECTROPOL I SHEO ANO INSU LA TED WITH 3/2" M ] N-K IN SULATION AN D 2 . 5" TH I CK SILFLEX RADIAT I ON SHI EL DIN G MATER I AL.

27 . CONNECTION PO I NT FOR F L E X EQUJPMENT.<}QI>

B B S1-I M E Q U I p TAN K O - I

~

VALVE. INTERLOCKED WITH REACTOR COOLANT 6.

SYS TEM PRESSURE. SI G W A L - ~ ~  : 3/4 E.LBOW TAPS FOf\ FLOW ME.T£R. illA) I o 5" .1/4_

REF Dlo/G DC-663217*5 ~TC -

A

l. LOCATE. ABOVE. RE S 1DUA.L '"'EAT REMOVAL f>UMP SHIELDI NG . ~ 8. UNIT DIAB LO CANYO N POWER PLANT - PG& E CO .
4. All @ ITEM tiOS ARE. SHOWN WITMOOT PRE.F IX PGE-AC, RESIDUAL HEA T REMOVA L SYSTEM REF ER TO@) STATUS REPORT DC-663200*47. 9. LOCAlE ORIFICE FLOW HE.TER INDICATION OUTSIDE 01= SHltLD WA.LL. )35-C,E.) DRAW i NG SHEET PAGE REV
5. 15. ANCHOR/DAR.Lit.JG, P0 . .3721 1, TC:/D DV/6 G00.:0473- 2~0.
10. 300* 316 SS FI.ANGES )36--B,D) ANO 4 PCS FLUSHING SPOOLS FLANGES Ctl LINE t.c> 110 g, 111.

8742.A D'NG.*Co~473-2Soi ~ 87426 D\.l.-641=G00&473-254~

I& VELAN MODEL W04 -2074B-13MS,0WG . ttb00b473 -l,8, 5/c. ,4-H550CD<E:£)