7 to Updated Final Safety Analysis Report, Chapter 3, Figure 3.2-22, Drawing 108022, Revision 40, Sheet 4, Turbine and Generator Associated Systems
ML23241A273
Person / Time
Site: Diablo Canyon  
Issue date: 05/25/2023
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23241A052 List: ... further results
References
DCL-23-044
Download: ML23241A273 (1)


Text

E D

C B

'10

'11 AIR SID E SEAL OIL-- ------~-

PRESSUR E GAUGE RANGE OTO 160 PSIG P I -2 MAJN BEAR I NG OIL FEED

~

MAIN BEAR I NG-----

HYDROGEN SEAL-----

~~~B ~ ~~~ ~~:~I~~ L 06~A1~-- - --- ------

TANK LEVEL LS ---------- ---

'12

'13 HYDROGEN INN ER-COOLED TURBINE GENERATOR VENT _I.

TRAP

'1'1 COMB INED DEFOAMING TANK --- -

ORA IN AND GAS PRESSURE SENS ING L I NE HYDROGEN SI DE SEAL..------------

01 L DRAIN r-


D20 MA IN BEARING OIL RETURN f-- ---- H

___ J _____________________________ _

PRESSURE EQUAL l ZING 1

~~~~~~E~Q~1~~ z;N ~i 6~~A ~E0~ ~~E J~~~~S p~6~~ D~6 G~OR 208 FLOAT VA L VE OPENS WITH LOW OIL LEVEL.

JAC KS PROVIDED FOR OPENING OR CLOS 1 NG Vt VE IN EMERGENCY/

OPEN I NG OR CLOS I NG VA L VE IN EMERGENCY~

AIR SIDE SEAL OI L 21 I 2 I 0 PRESSURES i,

A IR SI DE-HYDROGEN S I DE DIFFERENT I AL PRESSURE 1

GAUGE.

RANGE MINUS 25 "

TO PL US 25 "

OPERATION OR MINUS 2" H,O i

2 15 J~P l P I 4 Al L___L__-,v,_, 234+

SEAL OIL THERMOMETER~

2 13 235 RANGE 30 TO l 80°F Tl - 2

~ :- ~ --~

I S-1/2 V 7 DIFFERENT I AL PRESSURE~ i ffi-SWITCH FOR HYDROGEN

~

V-3 SIDE DUPLEX FILTER ITYPli

[

HYDROGEN SIDE OUPLE X--------1-- --

F!L TER OC-663282-75 235C-B 35

~

J -3/4"

~~~~6~~~~ 5 FOR l V-0673 THERHOCOUPLES i

o THROTTLED POSIT I ON

-I--_

LOCK THIS VALVE I N ~ :

T ] - 5 240 PS - I 243

~~~~~~R~H~~ITCH 2 --------------+-


_ 242 D lFFER ENT I AL PRESS-URE DECR EASES TO SEA L----:

SUPPLY UN IT

'--- R V 63 PRESSURE REL I EF s

VALVE SET AT 150PSIG A2 clli PROVISIONS FOR CUSTOMERS THERMOCOUPLES FLUSHLINE 11 1 UJDORI J1.i SEA L OIL SUPP LY 2 17

'15

'16 MAIN O I L FEED BEAR I NG

~

A I R SIDE \

OIL INLET

)( - 297 FROM GEN BRG OIL ORA l N L OOP SEAL

~HYDROGEN SIDE H IGH LEVE L ALARMS ( 297C -BI 33 ) jl, 04 2008 ADM I F xC2 AL AN GL EN BARTA EL ECTR I CA L E 927 1 9/30/2009 REVISED PER DC2-SJ-50835-0 A-E D\..'~

~E IV

,~orESS]ONAL ENGI I\EER
,E DJSC.

rE" PE EXP.

'17

'18

'19 LEGEND

-IX}-

VALVE ( NORMALLY OPEN)

PRESSURE GAUGE VA L VE

( NORMAL L Y CLOSED)

~

THERMOMETER

-I>+

VA L VE

( NORMALLY THROTT LED I fee--

ELECTRICAL CONNECT I ON

~

CHECK VA L VE

[Q]

PRESSURE SW I TCH

+I+ REL! EF VA L VE clli II ORJF ICE

[IQ]

DEFOAMJNG TANK L EVEL - HIGH

[DJ A I R SIDE SEAL OI L PUMP-OFF

[I]

SEA L OIL PRESSURE - LOW

[I))

HYDROGEN S I DE L EVEL - LOW

[8j SEA L OIL TURBINE BACKUP PRESSURE - LOW

@]

HYDROGEN S I DE SEAL O I L PUMP - OFF IT§]

AIR SIDE SEAL OI L BACK UP PUMP - RUNNING CON DE NS ED OPERA TI NG INSTRUC TI ONS SEE J NS TRUC TI ON BOOK FOR COMPLETE OPERAT I NG I NS TRUCT I ONS GENERA L - SEAL O I L PRESSURE MUST BE MAINTAINED AT THE HYDROGEN SEA L S WHEN HYDROGEN I S 1 N THE GENERA TOR OR WHEN THE SHAFT IS TURNING.

THE HYD ROGEN PRESSURE MA Y BE VARIED UP TO 75 PSIG.

SEAL OIL PRESSURE I S NORMA L LY MAINTAINED AT 12 PS I ABOVE THE HYDROGEN PRESSURE.

3 PSI IS REQUIRED TO MAINTAIN A SE AL WHEN RUNNING.

EXTRACTORS SHOU L D BE OPERA TED CONTINUOUSLY WHEN THE I S FI LL ED WITH HYDROGEN.

HYDROGEN SHOU L D BE PURGED FROM THE GENERATOR BEFORE MAIN OIL RESERVOIR I S DRAINED.

~ ~~~~~x T6 I ~ ~~~~u~~~6~ o~A~~
L o~/!~~2~6 ~:~R ELEMENT REPLACEMENT.

SEAL O I L SUPPLY - EMERGENCY SOURCES MAIN OIL PUMP ON TURB I NE SHAFTl SEAL OIL BACKUP PUMP WI LL MAINTAIN 75 PSIG ON MA IN O I L RESERV I OR HYDROGEN PRESSURE AIR S ID E SEAL OIL BACKUP PUMP TURNING GEAR BEARING O I L PUMPS-W I L L MAINTA I N 2 PSIG HYDROGEN PRESSURE THE TURB INE BACKUP REGULATOR VA L VE 264 OPENS WHEN THE DIFFEREN-T I AL PRESSURE AT THE SEALS DECREASES TO 8 PSI.

THEN I F THE SEAL D IFFERENT I AL PRESSURE DECREASES TO 5 PSI, PRESSURE SWITCH @]

ACTIVATES THE AIR SIDE SEAL OI L BACKUP PUMP ON THE SEAL OIL UNIT MID THE DIFFERENTIAL PRESSURE JS RESTORED TO 12 PSI.

THE NEXT AVAILABLE SOURCES OF EMERGENCY OIL AF TER THE AIR SIDE SEAL OI L BACKUP PUMP ARE THE TURNING GEAR BEARING O I L PUMPS ON TH E MAIN O I L RESERVIOR.

THESE CAN MA I NTAIN A HYDROGEN PRESSURE OF 2 PSIG ONL Y.

WHEN THE AIR SIDE SEAL Oi l BACKUP PUMP IS RUN-HYDROGEN PRESSURE SHOULD BE REDUCED TO 2 PSIG I F THE SEAL PUMP ON THE RESERVIOR IS NOT AVAILABLE.

TO PLACE EQUIPMENT IN OPERATION-SET VALVES AS INDICATED.

START A IR SIDE SEAL OIL PUMP ANO FI LL DEFOAMING TANKS ANO HYDROGEN S!DE DRA I N REGULATOR.

START HYDROGEN SIDE SEAL OIL PUMP.

EQUIP-MENT IS THEN IN NORMAL OPERATION.

UN I T 2 DIAB LO CANYON POWER PLANT - PG&E CO, TURBINE AND GENERATOR ASSOCIA TED SYSTEMS DRAWING SHEET PAGE REV 108022 4