AMSAC AC TUA TI ON SIGNA L IN1o\\\\EE9T &1 71101 STEAM GENERATOR 2 2, 3 L OW LOW LEVEL STEAM GENERATOR I 2/ 3 LOW LOW LEVEL
!SHEET 7)
STEAM GENERATOR 3 2 3 L OW LOW LEVEL STEA M GENERATOR 4 2/3 LOW LOW L EVEL (SHEET 71 LOSS OF POWER SIGNAL
( 1/2 UNDER VO~ J~~tT 0~ /OTH BUSES I SAFETY I NJECTION SIGNAL TRIP OF MAIN FEED PUMPS BUS TRANSFER TO DIESEL BUS TRANSFER TO DIESEL-------~
SAFEGUARD SEQUENCE SIGNAL1SH 8)-------
NANUAL START CONTROL ROOM 1NOTE 71 -----~
MANUAL START, LOCAL !NOT ES 2, 3 & 11={il MANUAL STOP, CONTROL ROOM <NOTE 11 MANUAL STOP, LOCA L I NOTES 2, 3 & Tl CLOSE ~LOlll'DOil'~
!'SOLA TI 0~ A~O 'SAHPLE LI HE \/AL \/E'S FOR AL L STEAM OE~HIATOR'S o+
cit+
LOCAL1/2 TURB JNE SPEED CONTROL
~-+---~~~~~6L S~~~~
MANUAL START LOCAL MANUA L STOP CONTROL ROOM MANUAL STOP LOCAL I NOTES 2 Is 3 )
1
- rn:i~ ~ ~g~rngti ~:~~i: ~~[:~rn LOCAL CON TROL OVERR IDES ALL OTHER SIGNALS.
LOCALOVERRJ OEACT UAl ESALARM IN CONTROL ROOM.
OPEN/SHUT INOICA T ION IN CONTROL ROOM.
MOTOROPERATINGL!GHTS INCONTROLROOH.
- 6.
JNOIVlDUAL FORE ACHVAL VE.
- 7.
INDIVIDUAL FOR EACH PUMP.
- 8. HIE TLJRIII HE SPEED COl,TROL IS HPIU,L. ACTUAL
!MPLEMEl,UTJOI, MAY HOT 11,CLUDE SPEED COHTROL.
<AMSAC CIJTPUT
,,._. AHO 'II' REL AYS ARE WIRED 1i. PARALLEL I. AMSAC OUTPUT A
STARTS M)TOR DRIVEH PUMP 3. AMSAC OUTPUT
- e* SURTS MOTOR DRIVEH PUI-F' 2.
JSOLATJOr. DEVICES ARE REQU IRED BETWEE'-
THE i.oi.-IE AMSAC CIRCUI TS AHO THE l[AU XI L IARYFEEDWA TERSTARTCIRCUITS.
- 10.
11,PUT TO THE AU XI LIARY FEEO'o,'ATER ACTUATJOI, DEV IC E rnR EACH AUXILIAR Y FEEDWATER TRAIi,.
1 1. SHE[THU"4:l[RSREF"ERTOTHEREF"ER[HC[i.UMBERSBELOW.
- 12. 'o,'HEl,EVERAPROCESSSIGNAL ISUSEDFORCOl,TROLAi.D IS DERIVEDFROH APROTECTION CHA1111EL.
ISOLATI0'-14..JSTBEPROV IDED.
- 13. THIS ORAW li.G IL LUSTRATES THE FUNCTIONAL REOU JREHEN TS OF THE REACTOR CONTROL
~~~~~:~~~A ~ll~~flA~~~ 1~AR0WAR[ I l>'f' LEMENTAT !ON, REFER TO THE APPL I CABL E REF ERENC ES ( NOTE I I l FUNCT IONAL LOGIC OIAGRAM INDEX AND SYM80lS FUNCTIONAL LOGIC DIAGRAM REACTOR TR IP SIGfJUS 3.FUNCTIONALLOGICOIAGRAMfWCLEARINSTRANDMANUALTRIPSIGNALS fLJNC TIOf1AL LOGIC DIAGRAM NUCLEAR INSTR PERMISSIVES Af.() BLOCKS fUNCT IOf1AL LOGIC OIAGRAM PRJMARY COO..ANT SYSTEM TRIP SIGNALS 6.fUNCTIONALLOGICOIAGRAMPRESSLJRIZERTRIPSIGf1ALS fUNCT IOfJAL LOGIC DIAGR AM STEAM GEfJERATOR TR IP SIGNALS fUNCT IONALLOGICO IAGRAMSAFEGUARDSACTUATIONSIGNALS 9.fUNCTIONALLOGICOIAGRAMROOCONTROLSANOROOBLOCKS
- 10. FUtKTIONAL LOG IC DIAGRAM STEAM DUMP CONTROL
- 11. FUNCTJONAL LOG IC DIAGRAM PRESSURIZER PRESSURE AND LEVEL COfilROL 12.FUNCTIONALLOGICDI AGRAMPRESSURIZERHEATERCONIROL
- 13. FUIKTJONAL LOGIC DI AGRAM HEOIIATER COfHROL Af10 ISOLAT ION
- 14. FUNCT!OfJAL LOG IC DIAGRAM HEDI/ATER CONTROL AfJD ISOLAT ION
- 15. FUNCTTONAL LOGIC DIAGRAM AUXILIARY FHOIIATER PUMPS STARTUP
- 16. FUNCTIONAL LOG IC DIAGRAM TURBINE TR IPS. RUNBACKS & SIGNALS 17.FUNCTJOfJALLOGICOIAGRAMAMSACSIGNALS 18.FUNCTIONALLOGICOI AGRAMSEJSMICTRIP 19.FUNCTIONALLOGICDIAGRAMDIGITALFIICONTSYSWPUTSIGNALVALIDATION
- 20. FUIKTIONAL LOG IC DIAGRAM DIGITAL FIi CONT SYS FIi FLO\r/CONTROLLER & Cy DEMAND
- 21. FUNCIJONAL LOG I C DIAGRAM DIGI TA L FIi CONT SYS CONT YCV SEO~ TRACKING LOGIC 22.FUNCTIONALLOGICOI AGRAMOI GIHLF \r/CONTSYSS IGNAL SELECTOR LOGI C 23.AT\r/SMITIGATIOfJSYSTEMACTUATIONCIRCUITRYIAMSACI
- 24. SCHEMAllCDIAGRAMAUXILlARYfE EO\r/A TERPUMPS
- 25. SCHEMATIC DIAGRAM AU XILIARY FEEOIIAIERPUMPS TURBINE CONTROL NUCLEAR SAFETY RELATED 5653074-3 5653074-4 5653074-5 5653074-7 5653074-8 5653074-9 5653074-1 1 5653074-12 5653074-13 5653074-14 5653074-15 5653074-16 5653074-17 8759077 5653074-19 5653074-20 5653074-2 1 495844 495845 495848 495849 495851 495852 495853 495854 495855 495857 495858 495861 495862 43 7583 455060 KEY D\./G. SECTI0N_3_
UNIT I FUNCTIONAL LOGIC DIAGRAM AUXILIARY FEEDWATERPUHP SSTARTUP