E D

r--- B 0

N I

co 0

I

<.D 0

C Q)

+-

CJ) 0 "D

0

,c wen

(/) "D s;J"

,s;J"

<.D V1 o (!)z A Ns;:r-N o -

0 L

11 N

Q) o::: O U) w -

=:J f--

II en z o

<t C) <t o:::ou 60 61 62 63 64 65 66 67 68 NOTES ca//T: s. DRIUAJ W/ QUICK*DISCOAJAJECT COUf'UNG W/ INTEGRAL CHeCK. VAL VE FOR EMEKGENC'I T/E -/N ro FIR£ PROTECTION SYS (1020!8*5A).CO/JPL!NG TO BE Re)IOVED WHEN DR//JIJIN6 15.RtQUJK~D.

7. T HE IN~UME:NT AIR,o FCV-3fd/ A~ i-cv-.. a HA5 SEEN ISOLAT5D, 80TH VALVE:!$,Afi?.E FULLY oPE=N, ~

~- DRf/lN W/ QUICK-DISCONAJECT COUPLING W/ INTEG/t/JL CHECK VIILV. DRAIN HOSE. TO l:JE /.JTTl1CIIED FOR Rou'r1NG FLOW 70 FLOOR DRAINS WHEN TPS 'TJE*/N (/v(JTE 5) IS OPERATIONAL COUPLING TO 8[ l?[M0VEO WHEN ORIIINING IS REQUIRED

(!(1103 IZD)

VITAL SERVICE SUPPLY HEADER "A.'

MISC SERVICE SUPPLY HEADER "c"

104 20 KI 05 18 VITAL SERVICE SUPPLY HEADER "B~

K 94 12 39 II l 0 39

~

CONTAINMENT WALL RESIDUAL H. X. 1-2 0C-663217-4 PX-42'.

~TE5 j

t L. 0. GEAR OIL 70 3/4 I

/

  • IXl--_...1--......1 1-E. C0, '

K 106 18 RES HEAT REM.

PP 1-2. ~EAL WTR. CLR.

DC-663217-9, 16 r{o~!2Z G Z7f.*Z

-cENTRlf'U(;AL CMA~'i.

PP. I - C PAC K.4\\,ij.£ 2"

( 43B-AI08)

~JNOTE-4 HEADER B

RETURN HEADER "c" RETUF?N HEADER "A" CENTRIFUGAL CHARGING PUMP 1-2 PACKAGE CLRS.

DC-663210-40, 47, 48, 49, 50 39 TCV-27 SAFETY INJECT ION PP H COOLER DC-663216-26, 32 (Kl §I l20)

REACTOR K 3279 l'l K 3281 n.

CONTAINMENT FAN COJLERS DC - 6E3079 -2,S UN IT 69 CLG. COi LS FAN MTRS.

H X.

HEADER *a*. COMPONENTS DI ABLO CANYON POWER PLANT - PG& E CO.

l.

£.LBOW T.4Ps FOR FLOW 1NelCJ11,.TION. ('=,0-D) 2..

R&.F'*li.. TO 5.1.5. PU!w\\P LU8E. OIL COOLIN~ S'{STEM 1 P.Gt ** E. RE.CORO NO. t>C * -3-Zl&.-2'- (<..5-C)

3.

~EFE.fi! 1"0 51S PP. SE.AL FL.USM SYSTEM OIA<.IU.M,OC {," 321:0 27 ~

4-. TE:ST P01"'1T 1 S'c:E NDTE<;> 2-*3 ~H,-SA CDoR.p C.3 -NOTES CON' T ABOVE-I NPG I C I S i ze r0_6_-_0_8_-_2_0_1_7-+-Z_N_S_4-+-F_x_C_2+-N_/_A-+-N_O_T_R_E_O_LJ_I_R_E_D_P_E_R_C_F_3_._ID_5-+-----l------+-------1 REVI SED PER DDN-2* 1425 DATE OWN RE IV PROFESSIONAL ENGINEER PE DISC.

PE;;

PE EXP.

COMPONENT COOL l NG WA TER SYSTEM DRAW i NG SHEET PAGE REV 1020 14 6 0 56 E

D C

B A