- ~~I-T-~~:.e_ MAIN TRANSFORMER \i"HT TRANSDUCER TOTLH
- su~ING&-AUXILIARYTRANSFORHER22Yil/HTTRANSOUCER SYSTEHiSCALING;.._AUXILIARYTRANSFORMER22XillATTTRANSDUCER
[NETWCJRK~AUXILIARYTRANSFORMER211i"ATTTRANSDUCER 14ATCHCIRCLE REFN0,3 MITCH CIRCLE REFN0.4 EEW30 FLEX OISCL!Nl 420KV 11' EQUIPMENT LDCA TI DNS
~
-:~~R:~~~R~~~~R~~N~R~~N~~~~D CONSOLE CH-STATION ELECTRIC CONTROL BOARD Efw16-COl+I.JNICATIONTONERECEIVEREaUIPMENTRACKl6 f/:illf -g~~L~sgp~m~~~GR8i~INET IN 12KV MG0S-2SKVIS0PHASEBUSDISCONNECTSWITCHM0TOR PCS-MAINTURBINECONTROLSYSTEMCABINET TRFM PMf35-MECHANICAL PANEL NO. 235 U1:m!lTRANSFORMERRG GENERATOR RELAY BOARD T
5O0VA RVH -STATIONELECTRICALRELAYBOARD'D' 1:1 SEI-EXCITATIONSWITCHGEARCUBICLEI 120VAC
~-GENERATOR NEUTRAL TRANSFORMER CUBICLE TQA21-AUXILIARYTRANSFORMER21CONTROLCABINET TQA22-AUXIL!ARYTRANSFORMER22CONTROLCABINET TQA22RXl,RX2-GROUNDRESISTORCAB4KVAUXTRANSF22X m~J:::~~!B::~** 0.9DPF
- ~~~~~u~;~ ~O~~~U~~N~E~~~~~~T C~~ F
- K~E~~~
- T~:~;F 4 22Y TGMA-B --- MAIN TRANSFORMER 0A HV BUSHING ADAPTOR TGMB-8 --- MAIN TRANSFORMER 08 HV BUSHING ADAPTOR TGMC-B --- MAIN TRANSFORMER 0C HV BUSHING ADAPTOR TVA2I-A,B1,C---AUX2ITRANSFORHERHVBUSHINGADAPTORSPHASEA,B&C THA22-A,B&C---AUX22TRANSFORHERHVBUSHINGADAPTORSPHASEA,BiiC EIBAUX---DOBLEINTELLDIAGNOSTICDEVICEFORAUXXFMRSHVBUSHINGS EIBl-tl---DOBLEINTELLDIAGNOSTICDEVICEFORMAINXFMRSHVBUSHINGS rnaPPMI ---500KVOPENPHASECH.I rnOPPM2---500KVOPENPHASECH.2 LEGEND DEVICE TABLE OF DEVICES DESCRIPTION RATING MFR CENERATOREXCITATIONFIELDAMMETER 0-I500A CENERATOREXCITATIONFIELDAMHETER 0-I500A AUXTRANSFORMERN0.22AHMETER 0-3000A TYPE CATALOG OR REF DWG UNITFREQUENCYMETER 50-70HZ l'ESTINGIIOOSEKR3-24I 7I4B538AIO SYNCHROSCOPE I20V-60HZl'ESTINGIIOOSE Kl-24I I86A235AOI GENERATOR NEUTRAL VOLTMETER o-Iov,o-Ioov GENERATOREXCITHION FIELD VOLTMETER 0-150 GENERATOR PM GENERATOR VOLTMETER 0-600V REGULATOR BALANCE VOLTMETER I5-0-I5V SYNCHRONIZING!RUNIBUS/LINEYOLTMETER 0-I50V l'ESTINGIIOOSE KA-24I 29IB46IAl2 SYNCRONIZING(INCOMING>CENVOLTHETER 0-1501/
l'ESTINGIIOOSE KA-24I 29IB46IAl2 AUXTRANSFORMERN0,2IVOLTMETER 0-ISOV AUXTRANSFORMERN0.22VOLTMETER 0-ISOV PULSE INITIATOR I20VAC l'ESTINGIIOOSE C0-2I IIIC285 REMARKS IOOMVSHUNTDC IOOMVSHUNTDC I2FORAIIXTRANSFOIIER21)
BUILT-IN POWER SUPPLY I000-0-IOOOMVARl'ESTINGIIOOSE KP-24I 409C7IIA62 2ELEMENT,30 AUXTRANSFORMERN0,2IVARl'ETER AUXTRANSFORMERN0.22VARMETER 0-40MVAR 2 ELEMENT,30 0-ISMVAR 2ELEMENT,30 0-ISOOMW l'ESTINGIIOOSE KP-24I 409C7IIA37 2ELEMENT,30 AUX TRANSFORMER NO. 21 WATTMETER 0-60MW AUX TRANSFORMER NO, 22 WATTMETER 0-25MW 2ELEMENT,30 2ELEMENT,30 GENERATORWATTHOURMETER S7.7-240V,2.5.I.ISEAIIIWIIOOII ALPHA P3FB0I00 3ELEMENT,4WIRE AUXTRANSFORMERN0.2IWATTHOURMETER I20V,2.5Al'ESTINGIIOOSE D2B-2F AUXTRANSFORHERN0.22WATTHOURMETER I20V,2.5Al'ESTINGIIOOSE 02B-2F AUXILIARY POTENTIAL TRANSFORMER II5-II5/66,SY GE YT-I557 UNITFREQUENCYTRANSDUCER 55-65HZ EST'EllllE-AllllS 2ELEMENT,3WIRE I2FORAUXXFMR22l USEDIIITHYTD&\ITD 2926048G09 (FORGENVARMETER) 760X99GI 30 l'l-'r' MM6284B GENERATOR VOLT TRANSDUCER lllllER[IISC*
000I2SB ORVTIIIIA2 I ELEMENT s
BUSHINGCAPACITANCE&POWERFACTORTAP
[!]
FIBER/ETHERNET MEDIA CONVERTER
~
AMMETER TRANSFER SWITCH
~6~Ec--:-i, ---'-""-'-"--l':'c~~"~~"':~"'~~"--,":~:,~':~~~~~~~~~~~~~R -----+-~:
~~:~~ :~~:'--+":~~:~:~~CJ:---1'~~
0~1,~~9~r:,~~~~3li'l"~c+' ~: "~,~,c~:"'E:~t"'~~~"~" "'=--i ffi~
~ 1:~
I I
I w
I I
REMOTE COMM I
i
(~UX XFM:!~K-UP i
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
L
_______ J
~
VOLTMETER TRANSFER SWITCH
---+f-TESTSWITCH
---jlf-@1, LIGHTNING ARRESTER ii OPERATING COUNTER NOTES I. XLWV3IK5A2DOESNOTREQUIRETHEUSEOFANEXTERNALPHASESHIFTING TRANSFORMER FOR VAR METERING.
- 2. TEST SWITCHES FOR 24.25/IA & 30/IA AUX CT'S ARE IN 'ISOLATE" POSITION, THEREARENOCURRENTCONTRIBUTIONSFROMAUX TRANSFORMERS2I &22TOTHEUNITOVERALLDIFFERENTIAL RELAYS87U2&87UH2.
- 3. ISO-METERING IS NO LONGER FUNCTIONAL, REF. NOTIFICATIONMS0536645.
REFERENCES DWG NO, I. DESCRIPTION OF ELECT SCHEMATIC DIAG, SYM:lOLS Ile CKT DESIG ___ 050003
- 2. LIST OF EQUIPMENT LOCATION CODES ________________ I030I3
- 3. SINGLE LINE METER Ile RELAY DIAG I2KV SYS BUS SECT D Ile E ____ 441227
- 4. SINGLE LINE METER Ile RELAY OIAG 4.I6KV SVS BUS SECT O Ile E ___ 441228
- 5. SINGLE LINE METER Ile RELAY DIAC 500KY SWITCHYARD ________ 56654 6.DELETED
- 7. SINGLE LINE DIAGRAM FOR STATION AUXILIARIES __________ 441220
- 8. MFR owe. UNIT AUX TRANSFORMER 21 li!ANUAL ____________ 6015581-11 9.ISO METERING MFR Dir/GS ______________________ 6015565-12
- 10. OPEN PHASE PROTECTION MFG DWGS _________________ 6024618 AUX TRANSFORMER NO. 21 WATT TRANSDUCER I20V,5A lllllER[IISC*
0001590li XL3Il5A2 2 ELEMENT,30 AUX TRANSFORMER NO. 22 WATT TRANSDUCER I20V,5A lllllER[IISC*
0001590li XL3Il5A2 2 ELEMENT,30 AUXTRANSFORMER22GROUNDRESISTORBANK 4I60V,340!11'ESTINGIIOOSE W/VAR TD DEH INPUT GENERATOR WATT/VAR TRANSDUCER I20V,5A IN:S~EIES PWV l'W/I20AC,5.l./2-20mV3ELEMENT,30 lE/I2CM:/SPC/SM DWG.602050I-54 43PW MAINTRANSFORMERTESTSWITCH GE CPOIID 40G2 GENERATOR LOSS OF FIELD RELAY 2.03-569,0.l'l-lH l'ESTINGIIOOSE KLF-I 2926333AIO 4IE AIRCIRCUITBREAKEREXCITERFIELD 600V,I600Al'ESTINGIIOOSE DB-50 EXCITATIONCl.l!ICLE 49HVAT2IWINOINGTEMPDETECTORAUXTRANSFORMER2IH,V.
QIJALITROL 104-318-01 REFS 49LVAT2I1/INDINGTEMPDETECTt1iAUXTRANSFORMER2I LV, QUALITROL 104-318-01 REF.8 49AT22X,Y
\IINDINGTElt'DETECTORAUXTRANSFORlf:R22 49MT WINDING TEMP DETECTOR Ml.IN TRANSFORMER 50NAT22X INSTRUMENTNEUTRALOVERCURRENTRELAY I-4A WESTINGIIOOSE SC 1876047 SONAT22Y INSTRUMENT NEUTRAL OVERCURRENT RELAY I -4A l'ESTINGIIOOSE SC 1876047 SISTU2 UNITSTARTUPOVERCURRENTRELAY 0.5-2A l'ESTINGIIOOSE SC 1878393 59NG2 GENERATORNEUTRALOVERVOLTAGERELAY 5.4-20V l'ESTINGIIOOSE CV-8 I83A205Al5 sv 1956708 59STIG2 UNITSTARTUPOVERVOLTAGERELAY 70-I60V l'ESTINGIIOOSE sv 1876094 59ST2G2 UNIT STARTUP V/Hl OVERVOLTAGE ALARM RELAY II~08\ I.t/1t~Z GE s,v I2STVIIAIA CV-25 90B572A22 63AT2I AUXTRANSFORMER2ISUDDENPRESSURERELAY REFS 63AT22 SUDDENPRESSUREDEVICE 900-009-63 64G2 GENERATORFIELDGROUNDDETECTOR 663293-26 78G2 GENERATOROUTOFSTEPRELAY 663102-64 BEl-8I0/U 290B225AIO 1875376 292B024A09 SIRU UNITRUNBACKRELAY 32G2A,B GENERATOR REVERSE POWER RELAY I20VAC l'ESTINGIIOOSE CRN-I 2908038A09 RFMl,2 RADIOFREQUENCYMONJTOR IS0-I,2 ISO METER I20V ~ WIRE 30 PS I GUAD 4+
REF. 9 5B7-2A,2B SOOKV TIE LINE DIFF RELAYS 125 voe GH:-ALSTIOI LFCBI02 663102-63 REC NO.
AUXTRANSFORMER22X AUXTRANSFORHER22Y STARTUP ONLY RUNNING STARTUP ONLY STARTUP ONLY ALARM ONLY SHORT TIME AUXTRANSFORMER2I AUXTRANSFORMER22 MAIN TRANSFORMER TRIPSUNIT'S500KVBKRS 0,I4AMINPICKUP PART OF GEN STATOR COOLING PROTECTION BTAGDMCONN
~'-"i_~t--*~*-"_'_"_"_'_'"_'"_"_'_c,_e_,_*e_,_,._e,_oa--+---+-'-"_"-+-__,_'__-,_"_'-_-+-"-e_,_,,_c __ ~l-rn~=~
MAIN TRANSFORMERS HY BUSHING CAP TAP DOBLE 03c_ I45I _0I BTA COM CONN
~
_,-l:;crn,>i,cj-Bi_j"'c'"°"'R'_'_'°"'R'_'_P"'"'"'"c"_*_'_'_'_'_':_c==:-i==:--.,cl,cy'-,j,,,,-::-,c,i,;.:_6;.,.,~'c"'"=_'_'"":_'"_,'=:-,!i~~
r::=-=--==--=--=-----=---
I 46TGM-I 500KV OPEN PHASE CH.I I PASSIVE DETECTION)
I25VDC
- 1 --- r
- Ill.IN 500KV MIDWJ.Y TRMISFOliMER BUSl<<l,I LINEl<<l.2 SYNCHRONilINGPOTENTIAL CAUTION: THE46DEVICE MAY BE A SOURCE OF ENERGY.
KEY DWG. SECTION_I_C_
I ~6TGM-2 500KV OPEN PHASE CH,2 I PASSIVE DETECTION)
I 25VDC I 46TGM-I I 500KV OPEN PHASE CH. I IACTIVE DETECTION I I 25VDC 1:-=~s CRI0-9068 I 0 l
~6TGM-21 500KV OPEN PHASE CH,2 IACTIYE DETECTIONI --~~~~--~~~~~:~-~0~1----1~--------------
,crr-ll SC-SCIENTIFIC COLUlflUS,AN ESTERLINE CO.
UNIT 2 SINGLELINEHETERANDRELAYOIAGRAM GENERATOR EXCITATION MAIN AND AUXILIARY TRANSFORMERS 34