ATTACHMENT 1 FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 1, ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE TABLE 2, ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE

FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number A2R23 Braidwood Generating Station, 35100 South Route 53, Suite 84, Braceville, Illinois 60407 Plant Unit No.

2 Commercial Service Date October 17, 1988 Refueling Outage Number A2R23 (if applicable)

Current Inspection Interval Current Inspection Period Fourth Inspection Interval (ISI), Third Inspection Interval (Containment ISI)

(1 ", 2"d, 3, 4'h, other)

Second Inspection Period (!SI and Containment ISI)

(1st, 2nd, 3'")

Edition and Addenda of Section XI applicable to the Inspection Plans ASME Section XI 2013 Edition, No Addenda Date and Revision of Inspection Plans December 01 st 2020 / Rev. O*

.....;;....::....:..;:;._..::....:.._:_::.....,...c;.;;~-'---'...;..;;..;...;._;;.L..__ ______________________

Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the inspection plans Same as above Code Cases used:

N-513-4, N-532-5, N-578-1, N-613-2, N-639, N-648-2, N-722-1, N-729-6, N-731, N-747, N-770-5, N-805, N-825, N-885 CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests, meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of A2R23 conform to the requirements of Section XI (refueling outage number)

Signed ~£V1....,e,uJ;'-=-'-=~*k_S_h_o.b...___/_~~"'--*-* _(_t:_/~_E._~.a._~_,_t),__ Date (Owner or Owner's designee. Title) 07/17/2023 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Hartford, Connecticut have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Y-.-Cc-----,. / S-\\Qlvnw4.~r-CA, Commission (Insp~'sSignature)

/

(National Board Number and Endorsement)

Date

TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Examination Item Category Number Item Description Evaluation Descriotion Relevant Condition Identified on Acceptable for service per EC 638969 (F-A)

F1.10 2CV06009C

& EC638985

TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Item Description Date Repair/Replacement Class Description Of Work Completed Plan Number 3

2SX2165B Replace degraded valve per IR 03/17/2023 WO# 5221535 4471064.

(Plan 2-22-001) 3 2CC9493B Replace Valve per EC 638864 06/06/2023 WO# 5035569 (Plan 2-23-020) 2 2SI8856A Replace valve with new one 07/06/2023 WO# 1466720 (Plan 2-23-019) 2 2SI018 Welding of 2SI-34-26 indication 07/06/2023 WO# 5360061 Per IR 04673991.

(Plan 2-23-016) 3 2VP01AD Weld buildup per IR 4673688 06/08/2023 WO# 5189536 and ECR 457846.

(Plan 2-23-015)