RS-23-084, Response to Request for Additional Information Regarding the Application to Revise Design Basis to Allow Use of Plastic Section Properties in Lower Downcomer Braces Analysis

From kanterella
(Redirected from ML23205A151)
Jump to navigation Jump to search

Response to Request for Additional Information Regarding the Application to Revise Design Basis to Allow Use of Plastic Section Properties in Lower Downcomer Braces Analysis
ML23205A151
Person / Time
Site: LaSalle  Constellation icon.png
Issue date: 07/24/2023
From: Lueshen K
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
RS-23-084
Download: ML23205A151 (1)


Text

4300 Winfield Road Warrenville, IL 60555 630 657 2000 Office RS-23-084 10 CFR 50.90 July 24, 2023 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 LaSalle County Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-11 and NPF-18 NRC Docket Nos. 50-373 and 50-374

Subject:

Response to Request for Additional Information regarding the Application to Revise Design Basis to Allow Use of Plastic Section Properties in Lower Downcomer Braces Analysis

References:

1.

Letter from K. Lueshen (Constellation Energy Generation, LLC) to Nuclear Regulatory Commission, "Application to Revise Design Basis to Allow Use of Plastic Section Properties in Lower Downcomer Braces 2023 (ML23013A076) 2.

Email from R. Kuntz (Nuclear Regulatory Commission) to J. Taken amendment request (EPID L-2023-LLA-In Reference 1, Constellation Energy Generation, LLC (CEG) requested an amendment to Renewed Facility Operating License Nos. NPF-11 and NPF-18 for LaSalle County Station (LSCS), Units 1 and 2 which proposed to revise the design basis for the lower downcomer braces.

In Reference 2, the Nuclear Regulatory Commission (NRC) requested additional information necessary to support its review of Reference 1. A clarification call was held to ensure a common understanding of the information sought.

This letter is being submitted to respond to the Reference 2.

The information contained in this does not alter the conclusion in Reference 1 regarding the no significant hazards consideration or the environmental considerations.

July 24, 2023 U.S. Nuclear Regulatory Commission Page 2 CEG is notifying the State of Illinois by transmitting a copy of this letter (without attachments) to the designated State Officials in accordance with 10 CFR 50.91, "Notice for public comment; State consultation," paragraph (b).

There are no regulatory commitments contained in this letter. Should you have any questions concerning this letter, please contact Mr. Jason C. Taken at (630) 657-3660.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 24th day of July 2023.

Respectfully, Kevin Lueshen Sr. Manager Licensing Constellation Energy Generation, LLC

Attachment:

Response to Request for Additional Information cc:

U.S. NRC Region III, Regional Administrator U.S. NRC Senior Resident Inspector, LaSalle County Station Illinois Emergency Management Agency and Office of Homeland Security Lueshen, Kevin Digitally signed by Lueshen, Kevin Date: 2023.07.24 12:23:38

-05'00'

ATTACHMENT Response to Request for Additional Information

1 of 7 Request for Additional Information LaSalle County Station, Units 1 and 2 License Amendment Request:

Revise Design Basis to Allow Use of Plastic Section Properties in Lower Downcomer Braces Analysis

RAI-1

Requirements:

fabricated, erected, constructed, tested, and inspected to quality standards commensurate with the importance of the safety function to be performed.

important to safety other than containment are designed, fabricated, erected, constructed, tested, and inspected to quality standards commensurate with the safety function to be performed.

ainst systems, and components (SSCs), requires, in part, that the SSCs important to safety shall be designed to withstand the effects of natural phenomena such as tornadoes and hurricanes without loss of capability to perform their safety functions.

10 CFR 50, Appendix A, GDC 16, "Containment Design," requires that reactor containment and associated systems shall be provided to establish an essentially leak-tight barrier against the uncontrolled release of radioactivity to the environment and to assure that the containment design conditions important to safety are not exceeded for as long as postulated accident conditions require.

esign Basis," requires that the reactor containment structure, including access openings, penetrations, and the containment heat removal system shall be designed so that the containment structure and its internal compartments can accommodate, without exceeding the design leakage rate and with sufficient margin, the calculated pressure and temperature conditions resulting from any loss-of-coolant accident. This margin shall reflect consideration of (1) the effects of potential energy sources which have not been included in the determination of the peak conditions, such as

ATTACHMENT Response to Request for Additional Information 2 of 7 energy in steam generators and as required by § 50.44 energy from metal-water and other chemical reactions that may result from degradation but not total failure of emergency core cooling functioning, (2) the limited experience and experimental data available for defining accident phenomena and containment responses, and (3) the conservatism of the calculational model and input parameters.

LSCS Updated Final Safety Analysis Report (UFSAR), Revision 13, the last paragraph on Page 1.2-15,

Background:

The license amendment request dated January 12, 2023, (Agencywide Documents Access and Management System (ADAMS) Accession No. ML23013A076), states:

a) with Exelon on 5/18/2020, the reduction in thickness for an operating life of 40 corr = 1 mil/year. In Section 3.0, are no unverified assumptions used in the preparation of t b) downcomer vents... are put into the PIPSYS model to determine the moments c) the lower downcomer braces and gusset plate section, Licensing Action LI d)

(Sgp to be 184 in3 and 29.54 in3, respectively.

e) Based on the review of the calculations in Attachment 3, the staff did not find any calculations qualifying the welds at the connection of lower downcomer bracing members.

f)

As previously discussed, LC #7 controls for the bracing members based on the existing analyses and is considered in this evaluation. The allowable stresses for

ATTACHMENT Response to Request for Additional Information 3 of 7 this LC (abnormal extreme environmental) are defined per Table 4.3-2 of the LaSalle DAR (Ref. 1c) and are provided below:

S7 = 1.6*AISC allowable not to exceed 0.95Fy Consistent with the existing evaluations, the maximum allowable stress of 0.95Fy is applicable to axial tension and bending, as well as axial compression. Section 1.7 of Cale.

187 (Ref. 3a) states that an allowable stress of 0.95Fy is acceptable for axial compression loads since the loads are dynamic in nature and last only a short time.

g) per SRP Section 3.6.2 (Ref. 8b), Subsection III.2.a, a 10% increase of the minimum specified design yield strength may be used in the analysis to account for strain rate effects under dynamic loading. This increase is considered for the Issues:

a) It is not clear why the corrosion reduction in thicknesses of the structural members were limited to 40 years, and how the annual corrosion reduction is assured to be to be a linear value of 1 mil/year for the duration of the operations where the lower downcomer bracing members are in stagnant and unrefreshed water environment.

b) It is not clear whether the steel gusset plates, as plate-elements, can be modeled as integral parts of downcomer piping using the PIPSYS program. Is there a three-dimensional element in PIPSYS program that can characterize the gusset-plates in mathematical models?

c) It is not clear how the American Institute of Steel Construction (AISC) code can be implemented to determine plastic section property(ies) to qualify the structural integrity of seismic Category I SSCs.

d) The values of elastic and plastic section modulus of effective gusset plate section are calculated in one of the orthogonal directions only. However, based on the configuration in Figure 2.1-section properties of gusset plate configuration are different and shall be calculated in both orthogonal directions.

e) It is not clear whether the stresses of welds at the connections of lower downcomer bracing members are within the weld acceptance criteria since no weld calculations are provided in the application.

ATTACHMENT Response to Request for Additional Information 4 of 7 f) It is not clear why the calculated shear stresses were not compared against the acceptance criterion for shear stresses (0.95 x Fy / (3)1/2 = 0.548 x Fy) as it was provided in Table 3.8-9 in Revision 13 of the LSCS UFSAR.

g) Standard Review Pl Accession No. ML16088A041) specifically provides information concerning break and crack location criteria and methods of analysis for evaluating the dynamic effects associated with postulated breaks and cracks in high-and moderate-containment. Then a 10 percent increase of minimum specified design yield strength (Sy) to account for strain rate effects may not be applicable for the structural members of the supports. Therefore, it is not clear whether any other industrial and/or regulatory requirement(s) allows the use of a 10 percent increase of minimum specified design yield strength (Sy) in the analyses to account for strain rate effects for the structural members of seismic Category I supports.

Requests:

a) Justify why the corrosion reduction in thicknesses of the structural members were limited to 40 years, and how the annual corrosion reduction is assured to be to be a linear value of 1 mil/year for the duration of the operations.

CEG RESPONSE:

The corrosion reduction in thicknesses is based on the original license period of the plant (40 years). The downcomers and bracing are included in the LSCS ASME Section XI, Subsection IWE Aging Management Program (AMP) to support License Renewal. The AMP will cover the Period of Extended Operation. The corrosion rate of 1 mil/year is a conservative value, as documented corrosion rates of weathering steels with similar chemical properties to that of ASME A618 Type II are noted between 0 to 1 mil/year per existing industry references. (U.S.

Metals Handbook 9th with the standard industry guidance for weathering steels. Once the oxide layer forms, over the period of plant operations the corrosion rate can be considered linear due to the corrosion resistance properties of the material.

b) Confirm whether the steel gusset plates, as plate-elements, can be modeled as an integral part of downcomer piping using the PIPSYS program. Is there a three-dimensional element in the PIPSYS program that can characterize the gusset-plates in a mathematical model? If not, justify whether the closed pipe element behavior is representative of open-sections, like gusset-plates, in analytical mathematical models under external loading conditions.

ATTACHMENT Response to Request for Additional Information 5 of 7 CEG RESPONSE:

The PIPSYS models used as input for this calculation were created during original plant design and were not updated as a result of this work. The downcomer system was modeled using beam elements that connect at nodes, as is typical practice. This is also how buildings are modeled in current engineering practice, where connecting elements (gusset plates, clip angles, etc.) are not part of the Finite Element Analysis model. As such, the gusset plates were not explicitly modeled.

Given the relatively short length of the gusset plates in relation to the overall length of the downcomer braces, using the brace section properties to model the gusset plates will have negligible impact on model stiffness. Therefore, this simplification, which is typical of engineering practice in the commercial and nuclear industries, is considered an acceptable approach.

c) Justify the use of plastic section properties under the AISC code to qualify the structural integrity of seismic Category I components.

CEG RESPONSE:

AISC does not restrict the use of plastic design, and the more recent AISC codes (including the AISC N690 nuclear code) use plastic section properties for flexural capacity of beams as a default (Mn = FyZ). The 7th Edition AISC Manual includes a plastic design selection table for shapes used as beams or columns in Part 2 of the Manual.

The overarching criterion for Category I design is that the structure will allow for safe shutdown of the plant. Use of plastic section properties does not invalidate this consideration. For example, Table 3.8-

-11 of the Quad d) Does the calculations of the elastic and plastic section properties of gusset plate provided in support of the amendment request consider forces in each orthogonal direction including combination of forces? If the provided analysis does not consider forces in each orthogonal direction justify the analysis or provide revised analyses as needed to support the amendment request.

CEG RESPONSE:

Section properties about each primary axis of the gusset plate are considered in Calculation L-002547 R0A (Section 2.0, Design Input #3). For a cruciform section, bending about one of the primary axes results in essentially zero stress in the section of the cross on the axis of flexure since it is at the neutral axis. Calculation L-002547 R0A considers the bounding moments about each axis, but because of the cruciform configuration, the stresses are not additive. See Section 7.4 of the calculation.

ATTACHMENT Response to Request for Additional Information 6 of 7 e) Provide assurance that the as-built weld joint configuration at the connections of critical locations of the lower downcomer bracing members meets the acceptance criteria.

CEG RESPONSE:

Per the design drawings, the downcomer brace gusset plate welds are either Complete Joint Penetration (CJP) welds or through-thickness Partial Joint Penetration (PJP) welds with a reinforcing fillet weld, which provide a weld strength equal to or greater than the base metal.

f) Justify why the calculated shear stresses, in the steel gusset plates, were not compared against the shear acceptance criterion as provided in Table 3.8-9 in Revision 13 of the LSCS UFSAR.

CEG RESPONSE:

Shear was determined to be noncritical in the design basis evaluations (Calculations 187, 187B, and 187K). Analysis L-002547 Rev. 0A is consistent with this approach.

Moreover, given the relatively large span-to-depth ratios of the brace members and the fact that the ends of the braces are moment connected, shear is not a controlling limit state by inspection, since the axial load and moments and the ends of the braces are very large.

For comparison, the web of the cruciform section that comprises the brace gusset plate has a shear capacity of approximately 0.55 x (50 ksi) x (10.92in) x (0.92in) = 276 kips, significantly higher than any of the member shear results tabulated in the design basis calculations.

g) Indicate the engineering requirement, industry standard, or code provision that allows the use of a 10 percent increase of minimum specified design yield strength (Sy) in the analyses to account for strain rate effects for the structural members of seismic Category I supports.

CEG RESPONSE:

Section 6.2 of the L-002547 R0A analysis discusses that this 10% increase is acceptable per Standard on 3.6.2 is specific to dynamic effects associated with pipe rupture and pipe whip restraints. While downcomer venting and seismic loading is not precisely pipe rupture, it is still a high-energy, dynamic phenomenon, and as such the use of a 10% increase to account for strain rate effects is consistent with the above-described accepted industry practice.

Additionally, AISC N690-18, Table A-

ATTACHMENT Response to Request for Additional Information 7 of 7 c increase factor of 1.1 for 50-ksi steel.