UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Heath Baldner, Director, Licensing NAC International 3930 East Jones Bridge Road, Suite 200 Norcross, GA 30092

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE MODEL NO. OPTIMUS-L PACKAGE

Dear Heath Baldner:

By letter dated November 2, 2022 (Agencywide Documents Access and Management System

[ADAMS] Accession No. ML22306A109), NAC International (NAC) submitted an application (ML22306A113) to allow for the transport of TRISO compacts in a new basket within the NAC OPTIMUS-L package.

This letter is to advise you that the information needed to continue our review is described as request for additional information (RAI) in the enclosure to this letter. Please note that your RAI responses should be provided by August 31, 2023. If the RAI responses are not received by this date, the staff may discontinue any further review.

Please reference Docket No. 71-9390 and Enterprise Project Identifier (EPID) No. L-2022-LLA-0142 in future correspondence related to this request.

Sincerely, Pierre M. Saverot, Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-9390 EPID L-2022-LLA-0142

Enclosure:

RAI July 17, 2023 Signed by Saverot, Pierre on 07/17/23

ML23193A542(pkg). ML23193A548(ltr), ML23193A545(encl)

OFFICE NMSS/DFM NMSS/DFM NMSS/DFM NMSS/DFM NAME PSaverot BPatel TBoyce DMarcano DATE 7/12/2023 7/13/2023 7/13/2023 7/13/2023 OFFICE NMSS/DFM NMSS/DFM NMSS/DFM NAME JBorowsky WWheatley YDiaz-Sanabria DATE 7/13/2023 7/13/2023 7/13/2023